Literature DB >> 31701247

Clinical performance of titanium-zirconium implants with a hydrophilic surface in patients with controlled type 2 diabetes mellitus: 2-year results from a prospective case-control clinical study.

José J Cabrera-Domínguez1, Lizett Castellanos-Cosano1, Daniel Torres-Lagares2, Manuel Pérez-Fierro1, Guillermo Machuca-Portillo3.   

Abstract

OBJECTIVE: Analyze the 2-year clinical performance of single-unit titanium-zirconium (TiZr) alloy narrow-diameter (3.3 mm) dental implants with a hydrophilic surface (Straumann® Roxolid®, SLActive®) in patients with controlled type 2 diabetes mellitus (T2DM), measured using the glycated hemoglobin A (HbA1c) concentration test, compared with results in individuals without T2DM.
MATERIAL AND METHODS: The studied sample consisted of 28 patients, 14 with T2DM (study group) and 14 without (control group). The plaque index, bleeding on probing, probing depth, clinical attachment level, gingival biotype, and marginal bone loss (MBL) at the site of the implants were assessed. HbA1c levels were assessed in all patients during each checkup.
RESULTS: Two years after implant placement and prosthetic restoration no implant failures were reported in either group, resulting in 100% survival and success rates in both groups. No statistically significant differences in MBL were found between the control and study groups (p > 0.05).
CONCLUSIONS: Within the limitations of this study, it can be concluded that reduced-diameter TiZr alloy implants with a hydrophilic surface represent a safe and predictable treatment option for patients with well-controlled T2DM. The clinical performance was comparable with that observed in individuals without T2DM in the medium term. CLINICAL RELEVANCE: The narrow implants placed in patients with T2DM with well-controlled glycemia (HbA1c) showed a marginal bone loss and success and survival rates similar to those of the control group without DM2, in the medium term.

Entities:  

Keywords:  Dental implants; Glycated hemoglobin a; Hydrophilicity; TiZr alloy; Type 2 diabetes mellitus

Year:  2019        PMID: 31701247     DOI: 10.1007/s00784-019-03110-9

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  5 in total

1.  Histomorphometric analysis of implant osseointegration using hydrophilic implants in diabetic rats.

Authors:  Alessandra Julie Schuster; João Luiz Bittencourt de Abreu; Natalia Marcumini Pola; Lukasz Witek; Paulo G Coelho; Fernanda Faot
Journal:  Clin Oral Investig       Date:  2021-03-25       Impact factor: 3.573

Review 2.  From Bench to Bedside in Precision Medicine: Diabetes Mellitus and Peri-Implantitis Clinical Indices with a Short-Term Follow-Up: A Systematic Review and Meta-Analysis.

Authors:  Mario Dioguardi; Stefania Cantore; Salvatore Scacco; Cristian Quarta; Diego Sovereto; Francesca Spirito; Mario Alovisi; Giuseppe Troiano; Riccardo Aiuto; Daniele Garcovich; Vito Crincoli; Luigi Laino; Michele Covelli; Annarita Malcangi; Lorenzo Lo Muzio; Andrea Ballini; Michele Di Cosola
Journal:  J Pers Med       Date:  2022-02-08

3.  A Pilot Study with Randomised Controlled Design Comparing TiZr Alloy Dental Implants to Ti Implants.

Authors:  Kristina Hultin; Annelie Eriksson; Christina Backe; Ulf Johansson; Kostas Bougas
Journal:  J Oral Maxillofac Res       Date:  2020-12-31

4.  Implant stability of narrow diameter implants in hyperglycemic patients-A 3-month case-control study.

Authors:  Daniel Diehl; Marianna Winkler; Hakan Bilhan; Anton Friedmann
Journal:  Clin Exp Dent Res       Date:  2022-05-16

5.  One-year performance of posterior narrow diameter implants in hyperglycemic and normo-glycemic patients-a pilot study.

Authors:  Anton Friedmann; Marianna Winkler; Daniel Diehl; Mehmet Selim Yildiz; Hakan Bilhan
Journal:  Clin Oral Investig       Date:  2021-05-03       Impact factor: 3.573

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.