Literature DB >> 31692577

Hyaluronic Acid as an Alternative to Autologous Human Serum Eye Drops: Initial Clinical Results with High-Molecular-Weight Hyaluronic Acid Eye Drops.

Ria Beck1, Oliver Stachs1, Anita Koschmieder1, Wolfgang G K Mueller-Lierheim2, Sabine Peschel1, Gysbert-Botho van Setten3,4.   

Abstract

INTRODUCTION: Autologous serum eye drops (ASED) are used in the treatment of most severe stages of dry eye. Once introduced, it is currently considered impossible to return to other lubricating eye drops or other commercially available therapeutic regimen.
MATERIALS AND METHODS: In a randomized study, non-preserved high-molecular-weight hyaluronic acid eye drops were offered as an alternative to 11 patients using autologous serum treatment for at least 3 months. The control group (n = 5) continued their treatment with ASED. The verum group (n = 6) used very-high-molecular-weight hyaluronic eye drops (Comfort Shield®) instead of the ASED.
RESULTS: From four of initially six patients in the verum group that finished the study, 2 (50%) preferred to stay with the very-high-molecular-weight hyaluronic acid eye drops beyond the trial period, the other two returned to the earlier therapy with ASED. The control group continued their treatment as before and finished the study after 8 weeks.
CONCLUSION: For the first time, artificial eye drops, i.e., high-molecular-weight hyaluronic acid eye drops, offered an acceptable alternative to ASED. Some patients perceived these drops as even better than the patient's own serum. This is the first evidence that optimization of the molecular structure of hyaluronic acid can be used to create eye drops that are perceived to be better than other tested tear substitutes and even patients' own serum. This offers a new treatment perspective for patients with very severe dry eye disease.
Copyright © 2019 by S. Karger AG, Basel.

Entities:  

Keywords:  Autologous serum eye drops; Dry eye; Sjögren syndrome; Wound healing

Year:  2019        PMID: 31692577      PMCID: PMC6760367          DOI: 10.1159/000501712

Source DB:  PubMed          Journal:  Case Rep Ophthalmol        ISSN: 1663-2699


Introduction

Autologous serum eye drops (ASED), a valuable alternative in the treatment of severe dry eye disease [1, 2], are well tolerated and often preferred to tear fluid substitutes [3]. This is partly due to their surface-promoting and -reconstituting effects [4], which have become more predictable due to a fairly standardized production process [5, 6, 7]. Based on the concentration of biological factors in healthy tears [4], ASED are applied mainly in 20% serum concentration, although even higher concentrations (between 50 and 100%) are in use [7, 8, 9, 10]. Patients treated with 20% to 50% ASED four to eight times a day have reported subjective improvement in dry eye symptoms; investigators have also noted objective improvement in signs such as fluorescein staining and tear film break-up time (TBUT) [16, 17, 18, 19, 20, 21, 22, 23]. The content of cytokines and other proteins that are also present in tears have made ASED a valuable treatment alternative [11]. Some cytokines such as epidermal growth factor have been found to occur in similar concentrations in healthy human tears and serum, whereas others have not, such as TGF-β [3, 12, 13]. This observation contributed to the use of a diluted solution of serum to maintain TGF-β levels that are comparable with those of tears. Variations in osmolarity of the autologous serum are balanced by the diluent balanced saline solution [14, 15]. Serum eye drops are used in treatment of patients with several ocular surface disturbances such as Sjögren syndrome-related tear deficiency, tear deficiency associated with graft-versus-host disease, neurotrophic keratitis, persistent epithelial defects, superior limbic keratoconjunctivitis, and postoperative dry eye induced by LASIK. In all these conditions, investigators have reported objective improvements of clinical signs such as fluorescein staining and TBUT [16, 17, 18, 19, 20, 21, 22, 23, 24]. Being aware about these so far unmatched effects, we were interested in evaluating if the direct substitution of ASED with hyaluronate might be possible. To this issue, we have investigated this quest. Encouraged by initial results of an ongoing study with high-molecular-weight hyaluronic acid (Hyaluronan), we have, in a randomized trial, offered such eye drops as an alternative to patients on therapy with ASED and compared their efficacy with a control group of patients who remained on ASED therapy.

Materials and Methods

Eleven patients who had been on ASED treatment for at least 3 months gave their informed consent and were included in the study and randomized into two groups. In the verum group (6 patients), the ASED were substituted by high-molecular-weight hyaluronic acid eye drops for a period of 8 weeks, whereas the control group (5 patients) continued their ASED therapy (Table 1).
Table 1

Patient history and descriptive data of the verum and control group

PatientDrop-outAge, yearsGenderDuration of ASED treatment, months
Verum group
179MaleKeratitis filiformis45
276MaleAllergic conjunctivitis: diabetes; adipohepatic16
X32MaleAcute lymphatic leukemia; stem cell transplantation82
380FemaleNeuropathic keratopathy; herpes zoster OD; corneal ulcus; cataract43
X59FemaleAcute lymphatic leukemia; stem cell transplantation20
467FemaleSjögrensyndrome50

Control group
572FemaleKeratoconjunctivitis sicca; ptosis and incomplete lid closure OD6
X88FemaleKeratoconjunctivitis sicca39
667FemaleSjögren syndrome; n. opticus atrophy OD39
782FemaleKeratoconjunctivitis sicca; burning sensation; rheumatoid arthritis13
859FemaleGVHD with myelodysplastic syndrome; stem cell therapy10
At three visits (i.e., baseline, after 4 weeks, after 8 weeks), the symptoms were assessed using the Ocular Surface Disease Index (OSDI) questionnaire [27]. The use of drops during the study (ad libitum) was recorded in case report forms.

Autologous Serum Eye Drops

Within the highly standardized preparation procedure for ASED at the Rostock University Eye Hospital, full blood samples were transferred into serum vials, left at room temperature for 20 min, and after coagulation were centrifuged with 2,000 g at 10°C for 20 min. Aliquots were created and diluted 1:1 by adding 0.9% NaCl solution (balanced saline solution) and the vials were closed, mixed using a vortex mixer, and frozen at −18°C. The patients took their vials with frozen autologous serum home in a polystyrene box and kept them at −18°C. Only immediately before use did the patients defrost one vial and they stored the vial in use refrigerated at 2–8°C.

Hyaluronic Acid Eye Drops

Non-preserved eye drops containing 0.15% very-high-molecular-weight hyaluronic acid (Comfort Shield®, manufacturer: i.com medical GmbH, Munich, Germany) were used in this study. They contain only substances naturally occurring in the human eye.

Diagnostics

Corneal Fluorescein Staining

Preservative-free sodium fluorescein solution (Fluorescéine Faure 0.5% ophthalmic solution in 0.4 mL unit dose, SERB SAS, Paris, France) was applied. After blinking, 20–120 s after instillation, digital photos of the ocular surface were taken with a Canon EOS 5D camera (Canon Inc., Tokyo, Japan) connected to a Takagi SM-70N slit lamp (Takagi Seiko Co., Ltd., Nagano, Japan). Corneal fluorescein staining (CFS) grading was done according to the modified Oxford scale [28]. Additionally, the digital images were electronically transferred to the Reading Center at Freiburg University Eye Hospital for automated assessment of the staining. The images were binarized by means of adaptive thresholding and automated calculations resulting in a ratio considered to be equivalent to the percentage of the visible corneal area that is fluorescein stained. From this ratio, the automated Oxford grade of CFS was calculated [28].

Additional Investigations

Additional investigations included TBUT, where the average of three measurements was recorded, Schirmer I test without anesthesia (Mark Blu Schirmer Tear Test Ophthalmic Strips; OptiTech Europe BVBA, Antwerp, Belgium), and tear osmolarity using TearLab E-series osmolarity test system (TearLab Corporation, San Diego, CA, USA). In vivo confocal laser-scanning microscopy of the cornea was used as previously described [29, 30] using the Heidelberg Retina Tomograph (HRT II, Heidelberg Engineering GmbH, Heidelberg, Germany) in combination with the Rostock Cornea Module as described earlier [30]. The subjective symptoms of the patients were assessed at every visit using the OSDI questionnaire. Dropping frequency was also assessed: At the baseline visit, the patients were asked for the frequency of application of ASED. Throughout the study, the use of eye drops (hyaluronic acid eye drops or ASED) was recorded daily. Prior to the diagnostic procedures, the patients had not applied any eye drops for at least 1 h.

Statistics

Due to the limited number of participating patients, any significance analysis was omitted and a descriptive analysis was performed comparing absolute numbers and mean values.

Results

Out of 11 patients initially included in the study, three (1 control, 2 verum group) were discontinued within the test period prior to the scheduled end of 8 weeks due to “no show,” dementia, or timing issue. Eight patients (4 in each group) continued and followed the investigation as planned (Table 1). The symptoms as assessed by the OSDI score did – on average – not significantly change over the 8-week trial period, nor did the average dropping frequency (Table 2). Two patients in the verum group experienced an improvement, whereas the other two felt a worsening of symptoms.
Table 2

OSDI scores and dropping frequency of verum and control group

PatientBaseline4 weeks8 weeks
OSDI verum
171.944.441.7
243.861.160.0
365.667.572.5
468.875.063.6
Mean62.562.059.5

Dropping frequency verum
114/day13/day13/day
214/day8/day10/day
36/day10/day8/day
414/day18/day14/day
Mean121211

OSDI control
550.045.545.8
652.347.750.0
766.758.375.0
842.562.557.5
Mean52.953.557.1

Dropping frequency control
514/day5/day5/day
628/day11/day11/day
714/day7.5/day7/day
87/day14/day15/day
Mean169.59.5
The OSDI scores of the patients in the verum and control group did not correlate with any of the diagnostic signs observed in the study. By the end of the study, the symptoms of 2 of the 4 verum patients (No. 1 and 4), i.e., 50%, had improved. These patients decided to continue the use of high-molecular-weight hyaluronic acid eye drops instead of ASED. The symptoms of the other 2 patients (No. 2 and 3) got worse. These patients decided to return to the ASED therapy. In these patients, the offered treatment was found not to add any significant improvement for the patient. The dropping frequency of the hyaluronic acid eye drops was only slightly different from the ASED dropping frequency by the time of inclusion of the patients. On both groups, there was a minor decrease in reported dropping frequency during the study (Table 2). The results of CFS testing are provided in Table 3. As the condition of the ocular surface was severe, surface irregularities and alterations rendered some of the CFS unreliable. These were accordingly reported as ungradable.
Table 3

CFS, TBUT, Schirmer I test, and osmolarity of the verum and control group

PatientRight eye
Left eye
Baseline4 weeks8 weeksBaseline4 weeks8 weeks
CFS test (Oxford scale)
Verum1IIIIVIVIIVIV
2uuuIIIuu
3IVIVuIIIIVu
4IIIIVIIIIIIII

Control5uIVu00u
6IIIIIVIVIIIV
70II0II
8IVIVuIVuu

TBUT test, s
Verum13nd23nd1
2224434
3223113
42114294

Control5224338
6543444
716nd112nd
8322312

Schirmer I test, mm/5 min
Verum1112117
21549
30210
45536

Control50200
61000
7111114
80507

Osmolarity, mosm/L
Verum1291293293286
2287302282290
3u315306311
4u283u<280

Control5300u312306
6308307309302
7318u320306
8284301u295

u, ungradable; nd, not determined.

Similarly, on the rough surfaces with irregularities, a reliable TBUT was often not measurable (Table 3). The Schirmer I test was slightly more successful and revealed some improvement in both groups, indicating only a minor difference between the groups, with slightly better values in the verum group (Table 3). Osmolarity testing proved to be a real challenge in these patients as the tear meniscus in most patient eyes was minimal. Accordingly, in some patients, no sufficient volume could be retrieved and hence, the measurement was recorded as unmeasurable. Interestingly, however, in no patient, a osmolarity higher than 320 mosm/L was found and the difference between both eyes was minimal (Table 3). By the time of inclusion in the study, the subbasal nerve plexuses of the patients investigated by confocal laser-scanning microscopy were very heterogenous. There were significant differences from patient to patient from almost no to reasonable innervation. There were well-defined subbasal nerves in the verum group (see Fig. 1) as well as in the control group. No major differences between innervation and appearance of the subbasal nerve plexus at baseline and after 8 weeks could be observed. In general, the appearance of the cornea at the level of the subbasal nerve plexus looked extremely heterogenic in both verum and control group. These differences did not correlate with other signs and symptoms. Moreover, these differences did not have any predictive value for the decision of the patient to continue or discontinue with high-molecular-weight hyaluronic acid eye drops, even after the end of the study.
Fig. 1

Picture from corneal nerves in a patient from the verum group staying on hyaluronic acid eye drops even after the study.

Discussion

This is, to the best of our knowledge, the first report giving evidence that artificial eye drops are preferred by patients to products derived form their own blood, so far considered the last level of advanced treatment of most severe dry eye disease. In the current study, we could show that very-high-molecular-weight hyaluronic acid eye drops are perceived as a preferred alternative to ASED by some patients. This study outlines that hyaluronic acid alone, when presented to the diseased ocular surface in an optimal galenic formulation, in the right concentration, and with a molecular size of hyaluronic acid close to the natural hyaluronic acid occurring at the surface, is a possible alternative to the use of ASED for some patients. The authors are not aware of any report so far suggesting that the last resort of severe dry eye treatment, i.e., therapy with serum eye drops, could be successfully replaced by synthetic tear substitute eye drops. In our study, we could show that over a period of 8 weeks, 4 out of 6 patients who had been under ASED treatment for a long time could be switched to the treatment with high-molecular-weight hyaluronic acid eye drops without significant change of signs of ocular surface disease, and that 2 of these patients even experienced an improvement of symptoms as determined by the OSDI. On the other hand, 2 out of 4 patients opted for returning to the ASED treatment after trying the alternative regimen for 8 weeks. Possibly, for those patients, a combination of hyaluronic acid and serum eye drops could lead to a combination of beneficial effects by a gradual, slow release of growth factors over a prolonged period of time, resulting in a beneficial effect on the ocular surface, as a recently published study suggests [31]. Here again, ASED had to be used from the refrigerator. Interestingly, however, in such combination, the use of high-molecular-weight hyaluronic acid could promote the anti-inflammatory effect of serum eye drops, as reported by Stenwall and colleagues [11]. The use of very-high-molecular-weight hyaluronic acid eye drops as a replacement for ASED has practical aspects. Not only would it serve as temporary supplement or replacement for serum eye drops, it could also serve as initial substitute to serum eye drops when regulatory or cultural issues prohibit the access to serum eye drops or only allogeneic serum eye drops could be offered. Moreover, very-high-molecular-weight hyaluronic acid eye drops are not derived from blood and hence, do not carry the risk of infection. They do not require particular transport and storage like cooling/freezing and are less costly. This study emphasizes the importance not only of the very-high-molecular-weight hyaluronic acid contained in Comfort Shield® eye drops and its concentration, mimicking the rheology of healthy human tears, but of the entire galenic formulation. This study also supports the increasing evidence that osmolarity is not a suitable diagnostic tool in severe/very severe dry eye disease as we did not find a significant hyperosmolarity in any measurement (maximum value 320 mosm/L). This finding is in line with a previous report showing that tear osmolarity was not statistically different between healthy subjects (306 mosm/L) and patients with dry eye disease (302 and 301 mosm/L before and after treatment with serum eye drops, respectively) [32]. The application of isotonic eye drops to a normo-osmolar ocular surface avoids any provoked osmotic stress by fluctuations in osmolarity to injured and chronically inflamed ocular surfaces. This is a particularly relevant finding as hyperosmolarity (>308 mosm/L) has been outlined as the key causal factor in the pathophysiology of severely dry eye and the causative factor in the vicious circle of dry eye disease [33, 34]. Future and ongoing studies will provide further evidence on this important aspect. In the present study, all other signs of dry eye investigated (Schirmer test, TBUT, etc.) did not show any significant difference between the verum and control group. Furthermore, this study showed that in very severe dry eye disease, the condition of the surface may not allow the reliable use of an ocular surface staining score. Similar to these difficulties in the diagnostics of severe dry eye disease, confocal microscopy of the sub-basal nerve plexus did not provide any indication whether or not an individual patient would accept substitution of ASED by high-molecular-weight hyaluronic acid eye drops. When using ASED in the treatment of severe ocular surface disease, we should be aware that the serum composition of multi-morbid patients may be seriously affected by the general health of the individual patient. Although rather standardized in concentration and production, its composition is dependent on the blood composition, which is affected by the actual general health condition of the body [3]. In general, the concentration of various components is higher in the tear film than in serum, whereas others such as vitamin A is substantially higher in serum [35, 36, 37]. Serum lipid profiles are significantly altered in systemic disease such as connective tissue diseases [38]. Cardiovascular disease may reflect in altered levels of plasminogen activator [39]. Additionally, concentrations of VEGF and IL-6 were increased in patients with rheumatoid arthritis [40]. IL-1β and TNFα levels are elevated in the peripheral blood of patients with primary Sjögren syndrome [41]. Taking this into account, as well as the effect that the alterations vary with the intensity of the disease, i.e., also during the treatment, it becomes evident that the presence of quality and quantity of various factors in the serum may vary. This also implies a variation in efficacy and tolerability of ASED in the most severely affected eyes. It is not unlikely that the serum of patients with highest general disease activity might have deficient and potentially harmful composition. It is here that the high-molecular-weight hyaluronan eye drops offer a great advantage due to their reproducible composition and absence of potentially harmful substances. It is likely that high-molecular-weight hyaluronan eye drops offer significant advantages particularly for the treatment of severe dry eye in patients with severe systemic disease. Additionally, severe systemic disease seldom matches the option for frequent and repeated blood sampling. High-molecular-weight hyaluronan eye drops used in this study represent a so far unmet potential tool and, at least temporarily, an effective alternative to ASED. All the more so as there are patient groups that do not respond so well to serum eye drops. According to Hwang et al. [42], ASED might not be effective for the treatment of secondary Sjögren syndrome because of elevated serum proinflammatory cytokine levels. In such patients, the use of high-molecular-weight hyaluronan eye drops could offer a valuable alternative. However, as by today, there is a lack of specific guidelines that help to identify patients where the access to ASED due to systemic disease is either limited or where the quality of ASED, due to the nature of the underlying systemic disease, is suboptimal. It is these conditions that would favor the use of high-molecular-weight hyaluronan eye drops.

Conclusion

High-molecular-weight hyaluronic acid eye drops have unique features that resemble the natural hyaluronic acid at the ocular surface so much that apparently in some patients, these drops are perceived to be even better than the patient's own serum. The study clearly indicates that the molecular structure and size of the hyaluronic acid molecule has clinical relevance. This is the first evidence that optimization of the molecular structure of the hyaluronic acid molecule could lead to eye drops that resemble natural tears to a yet unmet extent. The results and their interpretation are limited because of the limited number of cases. In order to support the initial results presented herein, further prospective studies with a larger number of patients and, possibly, a switch-over design would be needed.

Statement of Ethics

The study, approved by the local Ethics Committee and by the German Bundesinstitut für Arzneimittel und Medizinprodukte (BfArM), is in accordance with EN ISO 14155 [25] and the Declaration of Helsinki, and is registered with the EUDAMED registration number CIV-16-06-015964. The study was sponsored and monitored by CORONIS GmbH (Munich, Germany), an organization with a quality management system for clinical research, certified and annually audited in accordance to the international standard EN ISO 13485 by a European Notified Body [26].

Disclosure Statement

Ria Beck and Gysbert van Setten have no financial interest in this publication. Dr. Wolfgang Mueller-Lierheim shares interest as sponsor of the study in his position as CEO of I-Com medical GmbH, Munich Germany.

Funding Sources

I-Com medical GmbH, Munich, Germany.
  40 in total

Review 1.  Serum application for the treatment of ocular surface disorders.

Authors:  K Tsubota; A Higuchi
Journal:  Int Ophthalmol Clin       Date:  2000

2.  An optimised protocol for the production of autologous serum eyedrops.

Authors:  L Liu; D Hartwig; S Harloff; P Herminghaus; T Wedel; G Geerling
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-03-09       Impact factor: 3.117

3.  Improving the anti-inflammatory effect of serum eye drops using allogeneic serum permissive for regulatory T cell induction.

Authors:  Per-Anton Stenwall; Marcus Bergström; Peter Seiron; Felix Sellberg; Tobias Olsson; Folke Knutson; David Berglund
Journal:  Acta Ophthalmol       Date:  2015-07-14       Impact factor: 3.761

4.  Treatment of dry eye by autologous serum application in Sjögren's syndrome.

Authors:  K Tsubota; E Goto; H Fujita; M Ono; H Inoue; I Saito; S Shimmura
Journal:  Br J Ophthalmol       Date:  1999-04       Impact factor: 4.638

5.  Tear evaporation from the ocular surface.

Authors:  K Tsubota; M Yamada
Journal:  Invest Ophthalmol Vis Sci       Date:  1992-09       Impact factor: 4.799

6.  Early detection of nerve fiber loss by corneal confocal microscopy and skin biopsy in recently diagnosed type 2 diabetes.

Authors:  Dan Ziegler; Nikolaos Papanas; Andrey Zhivov; Stephan Allgeier; Karsten Winter; Iris Ziegler; Jutta Brüggemann; Alexander Strom; Sabine Peschel; Bernd Köhler; Oliver Stachs; Rudolf F Guthoff; Michael Roden
Journal:  Diabetes       Date:  2014-02-26       Impact factor: 9.461

7.  Allogeneic serum eye drops for the treatment of severe dry eye in patients with chronic graft-versus-host disease.

Authors:  Chun-Chi Chiang; Jane-Ming Lin; Wen-Lu Chen; Yi-Yu Tsai
Journal:  Cornea       Date:  2007-08       Impact factor: 2.651

8.  Autologous serum eye drops diluted with sodium hyaluronate: clinical and experimental comparative study.

Authors:  José S López-García; Isabel García-Lozano; Luis Rivas; Nuria Ramírez; Rafaela Raposo; Maria T Méndez
Journal:  Acta Ophthalmol       Date:  2013-07-26       Impact factor: 3.761

9.  Comparison of clinical efficacies of autologous serum eye drops in patients with primary and secondary Sjögren syndrome.

Authors:  Jehyung Hwang; So-Hyang Chung; Sohee Jeon; Seung-Ki Kwok; Sung-Hwan Park; Man-Soo Kim
Journal:  Cornea       Date:  2014-07       Impact factor: 2.651

Review 10.  Autologous serum eye drops for dry eye.

Authors:  Qing Pan; Adla Angelina; Michael Marrone; Walter J Stark; Esen K Akpek
Journal:  Cochrane Database Syst Rev       Date:  2017-02-28
View more
  5 in total

Review 1.  Applications of Hyaluronic Acid in Ophthalmology and Contact Lenses.

Authors:  Wan-Hsin Chang; Pei-Yi Liu; Min-Hsuan Lin; Chien-Ju Lu; Hsuan-Yi Chou; Chih-Yu Nian; Yuan-Ting Jiang; Yuan-Hao Howard Hsu
Journal:  Molecules       Date:  2021-04-24       Impact factor: 4.411

Review 2.  Impact of Attrition, Intercellular Shear in Dry Eye Disease: When Cells are Challenged and Neurons are Triggered.

Authors:  Gysbert-Botho van Setten
Journal:  Int J Mol Sci       Date:  2020-06-18       Impact factor: 5.923

3.  The Effects of High Molecular Weight Hyaluronic Acid Eye Drop Application in Environmental Dry Eye Stress Model Mice.

Authors:  Takashi Kojima; Taeko Nagata; Haruka Kudo; Wolfgang G K Müller-Lierheim; Gysbert-Botho van Setten; Murat Dogru; Kazuo Tsubota
Journal:  Int J Mol Sci       Date:  2020-05-15       Impact factor: 5.923

Review 4.  Why Chain Length of Hyaluronan in Eye Drops Matters.

Authors:  Wolfgang G K Müller-Lierheim
Journal:  Diagnostics (Basel)       Date:  2020-07-23

Review 5.  Hyaluronic Acid: Its Versatile Use in Ocular Drug Delivery with a Specific Focus on Hyaluronic Acid-Based Polyelectrolyte Complexes.

Authors:  Saoirse Casey-Power; Richie Ryan; Gautam Behl; Peter McLoughlin; Mark E Byrne; Laurence Fitzhenry
Journal:  Pharmaceutics       Date:  2022-07-15       Impact factor: 6.525

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.