Literature DB >> 31690522

Highly Cross-Linked Polyethylene in Total Hip Arthroplasty in Patients Younger Than 50 Years With Osteonecrosis of the Femoral Head: A Minimum of 10 Years of Follow-Up.

Byung-Woo Min1, Chul-Hyun Cho1, Eun-Suck Son1, Kyung-Jae Lee1, Si-Wook Lee1, Kwang-Soon Song1.   

Abstract

BACKGROUND: Polyethylene wear and subsequent periprosthetic osteolysis remain a major concern of total hip arthroplasty (THA) failure in young, active patients with osteonecrosis of the femoral head (ONFH). The literature is lacking regarding the long-term performance of highly cross-linked polyethylene (HXLPE) in these patients. The purpose of this study is to evaluate long-term results for cementless THA using metal-on-HXLPE bearing couplings in patients younger than 50 years with ONFH.
METHODS: We retrospectively evaluated the clinical and radiographic results of a consecutive series of 85 THAs (in 67 patients) performed with HXLPE liners (Durasul) in patients younger than 50 years who had ONFH. All procedures were performed at a single institution by a single surgeon using the same type of implants. The minimum duration of follow-up was 10 years (mean, 13.5 years; range, 10-17.3 years). Wear was measured using computer software. Osteolysis was evaluated with the use of radiography and computed tomography.
RESULTS: The mean Harris hip score was 49.3 points (range, 26-68 points) before surgery, which improved to 93.6 points (range, 87-98 points) after surgery. Neither femoral nor acetabular components displayed mechanical loosening, and no components had been revised by the final follow-up evaluation. Radiographs and computed tomography scans did not demonstrate osteolysis. The mean liner wear was 0.037 mm/y (range, 0-0.099 mm/y). With the data available, univariate regression analysis did not demonstrate that age, sex, weight, activity level, underlying cause of osteonecrosis, liner thickness, or cup inclination had any influence on liner penetration.
CONCLUSION: Although the long-term effects of HXLPE particles remain unknown, the implant survivorship rate and wear rate in our study are promising and support the continued use of metal-on-HXLPE bearing couplings in these high-risk patients because they do not produce any of the issues associated with hard-on-hard couplings. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  femoral head; highly cross-linked polyethylene; osteolysis; osteonecrosis; total hip arthroplasty; wear

Mesh:

Substances:

Year:  2019        PMID: 31690522     DOI: 10.1016/j.arth.2019.10.021

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  Hip function in patients undergoing conservative treatment for osteonecrosis of the femoral head.

Authors:  Yusuke Osawa; Yasuhiko Takegami; Daisaku Kato; Masanori Okamoto; Hiroki Iida; Shiro Imagama
Journal:  Int Orthop       Date:  2022-09-14       Impact factor: 3.479

Review 2.  Characterisation of Selected Materials in Medical Applications.

Authors:  Kacper Kroczek; Paweł Turek; Damian Mazur; Jacek Szczygielski; Damian Filip; Robert Brodowski; Krzysztof Balawender; Łukasz Przeszłowski; Bogumił Lewandowski; Stanisław Orkisz; Artur Mazur; Grzegorz Budzik; Józef Cebulski; Mariusz Oleksy
Journal:  Polymers (Basel)       Date:  2022-04-09       Impact factor: 4.967

3.  Mid-term results of short versus conventional cementless femoral stems in patients with bilateral osteonecrosis of the femoral head.

Authors:  Yingyong Suksathien; Jithayut Suarjui; Chakkrit Ruangboon; Tossaporn Akkrasaeng
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-03-12

4.  [Treatment of osteonecrosis of the femoral head with vascularized bone grafting].

Authors:  Haibo Ding; Yang Wang; Yun Lu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-03-15

Review 5.  Nontraumatic Osteonecrosis of the Femoral Head: Where Do We Stand Today?: A 5-Year Update.

Authors:  Michael A Mont; Hytham S Salem; Nicolas S Piuzzi; Stuart B Goodman; Lynne C Jones
Journal:  J Bone Joint Surg Am       Date:  2020-06-17       Impact factor: 6.558

6.  Fixation vs Arthroplasty for Femoral Neck Fracture in Patients Aged 40-59 Years: A Propensity-Score-Matched Analysis.

Authors:  Jacob M Wilson; Corey A Jones; Jeffrey Scott Holmes; Kevin X Farley; Roberto C Hernandez-Irizarry; Thomas J Moore; Thomas L Bradbury; George N Guild
Journal:  Arthroplast Today       Date:  2022-03-20

7.  The Wear Rate and Survivorship in Total Hip Arthroplasty Using a Third-generation Ceramic Head on a Conventional Polyethylene Liner: A Minimum of 15-year Follow-up.

Authors:  Bum-Jin Shim; Sung-Jin Park; Chan Ho Park
Journal:  Hip Pelvis       Date:  2022-06-07
  7 in total