Literature DB >> 31686746

Efficacy and Feasibility of Chhattisgarh Balloon and Conventional Condom Balloon Tamponade: A 2-Year Prospective Study.

Nalini Mishra1, Kanchan Gulabani1, Sumi Agrawal1, Chandrashekhar Shrivastava1.   

Abstract

OBJECTIVE: To evaluate the clinical efficacy of two types of condom uterine balloon tamponade systems, namely Chhattisgarh condom balloon device "CG balloon (CGB)" having a central drainage channel as well as indigenous tying system to fasten condom to the catheter and conventional condom uterine balloon device (C-UBT) as a second-line intervention in post-partum haemorrhage (PPH).
MATERIALS AND METHODS: The present non-randomised prospective case series was carried out from December 2014 to September 2016 and included 60 women having PPH which was refractory to first-line management and who were treated with either of the two condom balloon tamponade devices prepared on spot. Women with allergy to latex, retained placenta, uterine rupture, anomaly, genital infection and/or malignancy were excluded. Case report forms were filled for all participants and analysed. Primary outcome was arrest of haemorrhage, and one of the secondary outcomes was cost and consistency of the devices.
RESULTS: CGB was used in 46 and C-UBT in 14 women. The overall success rate was 98.33%. The mean blood loss was 1417 mL. Women of C-UBT group had greater blood loss, higher inflation volume and delays due to technical issues (OR 7.6). CGB was cheaper and more consistent than C-UBT by omitting the use of suture material.
CONCLUSION: CGB and conventional condom balloon tamponade both are easy to use, feasible and efficacious for control of PPH, but CGB condom balloon device has the advantage of a central drainage lumen for real-time assessment of blood loss and therefore early corrective action. © Federation of Obstetric & Gynecological Societies of India 2019.

Entities:  

Keywords:  CG Balloon; Innovative condom balloon tamponade; Low-resource settings; Maternal mortality; Post-partum haemorrhage

Year:  2019        PMID: 31686746      PMCID: PMC6801252          DOI: 10.1007/s13224-018-1185-6

Source DB:  PubMed          Journal:  J Obstet Gynaecol India        ISSN: 0975-6434


  17 in total

Review 1.  Uterine balloon tamponade for the treatment of postpartum haemorrhage in resource-poor settings: a systematic review.

Authors:  K Tindell; R Garfinkel; E Abu-Haydar; R Ahn; T F Burke; K Conn; M Eckardt
Journal:  BJOG       Date:  2012-08-13       Impact factor: 6.531

2.  Use of an Innovative Condom Balloon Tamponade in Postpartum Haemorrhage: A Report.

Authors:  Nalini Mishra; Sumi Agrawal; Kanchan Gulabani; Chandrashekhar Shrivastava
Journal:  J Obstet Gynaecol India       Date:  2015-12-22

3.  The CG balloon is an innovative condom balloon tamponade for the management of postpartum hemorrhage in low-resource settings.

Authors:  Nalini Mishra; Chandrashekhar Shrivastava; Sumi Agrawal; Kanchan Gulabani
Journal:  Int J Gynaecol Obstet       Date:  2016-02-01       Impact factor: 3.561

4.  Condom Tamponade in the Management of Primary Postpartum Haemorrhage: A Report of three cases in Ghana.

Authors:  Ernest T Maya; Kennedy A Buntugu; Lovelace Aki; Emmanuel K Srofenyoh
Journal:  Afr J Reprod Health       Date:  2015-09

5.  Intrauterine condom tamponade in management of post partum haemorrhage.

Authors:  K Thapa; B Malla; S Pandey; S Amatya
Journal:  J Nepal Health Res Counc       Date:  2010-04

6.  Uterine tamponade using condom catheter balloon in the management of non-traumatic postpartum hemorrhage.

Authors:  Asmita Muthal Rathore; Sonali Gupta; Usha Manaktala; Sangeeta Gupta; Chandan Dubey; Mumtaz Khan
Journal:  J Obstet Gynaecol Res       Date:  2012-04-30       Impact factor: 1.730

7.  [Efficacy and safety of intrauterine Bakri balloon tamponade in the treatment of postpartum hemorrhage: a multicenter analysis of 109 cases].

Authors:  Yu Gao; Zilian Wang; Jianping Zhang; Dongyu Wang; Baomin Yin; Bin Zhu; Yanjun He; Hongying Hou; Wulan Cao; Xiaoying Liu; Yanping Yu; Shilei Pan; Lihua Liu; Zhijian Wang; Fangming Su
Journal:  Zhonghua Fu Chan Ke Za Zhi       Date:  2014-09

8.  Use of Bakri balloon tamponade in the treatment of postpartum hemorrhage: a series of 50 cases from a tertiary teaching hospital.

Authors:  Maiju Grönvall; Minna Tikkanen; Erika Tallberg; Jorma Paavonen; Vedran Stefanovic
Journal:  Acta Obstet Gynecol Scand       Date:  2012-10-17       Impact factor: 3.636

9.  The uterine sandwich for persistent uterine atony: combining the B-Lynch compression suture and an intrauterine Bakri balloon.

Authors:  Wendy L Nelson; John M O'Brien
Journal:  Am J Obstet Gynecol       Date:  2007-05       Impact factor: 8.661

10.  Postpartum hemorrhage in two women with impaired coagulation successfully managed with condom catheter tamponade.

Authors:  Rashmi Bagga; Vanita Jain; Sushmita Sharma; Vanita Suri
Journal:  Indian J Med Sci       Date:  2007-03
View more
  2 in total

1.  Effectiveness of uterine tamponade devices for refractory postpartum haemorrhage after vaginal birth: a systematic review.

Authors:  V Pingray; M Widmer; A Ciapponi; G J Hofmeyr; C Deneux; M Gülmezoglu; K Bloemenkamp; O T Oladapo; D Comandé; A Bardach; P Vázquez; G Cormick; F Althabe
Journal:  BJOG       Date:  2021-07-19       Impact factor: 7.331

2.  Cost-effectiveness of uterine tamponade devices for the treatment of postpartum hemorrhage: A systematic review.

Authors:  Joshua P Vogel; Alyce N Wilson; Nick Scott; Mariana Widmer; Fernando Althabe; Olufemi T Oladapo
Journal:  Int J Gynaecol Obstet       Date:  2020-10-30       Impact factor: 3.561

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.