Sean Banaee1, Shane S Que Hee2.
Abstract
The purpose of this study was to investigate the permeation of the glycol ethers, 2-ethoxyethanol (2-EE) and 2-butoxyethanol (2-BE) through disposable, nitrile exam gloves using a modified American Society for Testing and Materials (ASTM) closed-loop module. The purple unsupported, unlined, powderless nitrile glove from Kimberly-Clark was challenged by the two pure glycol ethers. Their permeation parameters were measured with the aid of a 2.54 cm ASTM F739 closed-loop permeation cell using water collection at 35.0 ± 0.5°C in a moving tray water bath, and capillary gas chromatography-mass spectrometry for quantification. Each set of experiments consisted of four standard permeation cells with water as the collection solvent. The steady state permeation rate for 2-EE of 4.83 ± 0.45 µg/cm2/min was about 4 times that of 2-BE (1.27 ± 0.11 µg/cm2/min). Permeation of the more nonpolar 2-BE was less than for 2-EE. Both solvents exceeded the ASTM threshold normalized breakthrough time in the closed-loop testing module. Glove samples failed to pass permeation criteria defined by Kimberly Clark and Ansell. Such gloves are not recommended as personal protective equipment for exposure to 2-butoxyethanol or 2-ethoxyethanol, even for very short period exposures. Glove manufacturers should reconsider existing permeation testing method for low volatile compounds and apply the closed-loop module due to higher sensitivity and accuracy.Entities:
Keywords: American Society for Testing and Materials (ASTM); Butoxyethanol; Ethoxyethanol; Glove; Nitrile; Permeation; Personal protective equipment
Year: 2019 PMID: 31685784 PMCID: PMC7286716 DOI: 10.2486/indhealth.2019-0146
Source DB: PubMed Journal: Ind Health ISSN: 0019-8366 Impact factor: 2.179
Average glove thickness (µm) and weight (gr) before and after exposure to 2-EE and 2-BE
| Analyte | Thickness before | Thickness after | Weight before | Weight after |
|---|---|---|---|---|
| 2-EE average | 105 ± 2 | 108 ± 2 | 299 ± 4 | 311 ± 10 |
| 2-BE average | 105 ± 1 | 107 ± 1 | 267 ± 6 | 280 ± 12 |
2-EE: 2-ethoxyethanol; 2-BE: 2-butoxyethanol.
Fig. 1.Permeation of 2-butoxyethanol through purple disposable nitrile gloves.
Fig. 2.Permeation of 2-ethoxyethanol through purple disposable nitrile gloves.
Permeation parameters of 2-EE and 2-BE through disposable purple nitrile gloves
| Analyte | Replicate | NBRTa | SSPRb | Dc × 10-6 | 20-Min | Total |
|---|---|---|---|---|---|---|
| 2-BE | 1 | 10 ± 10 | 0.9 | 1.6 | 5 | 80 |
| 2 | 10 ± 10 | 1.2 | 1.3 | 9 | 84 | |
| 3 | 10 ± 10 | 1.4 | 1.8 | 6 | 125 | |
| Average | 10 ± 10 | 1.2 ± 0.25 | 1.6 ± 0.2 | 6.6 ± 2.1 | 96 ± 24 | |
| 2-EE | 1 | 10 ± 10 | 3.9 | 5.6 | 19 | 211 |
| 2 | 10 ± 10 | 5.1 | 3.5 | 26 | 268 | |
| 3 | 10 ± 10 | 5.5 | 2.3 | 43 | 262 | |
| Average | 10 ± 10 | 4.8 ± 0.8 | 3.8 ± 1.2 | 29 ± 12 | 247 ± 31 | |
a: Normalized breakthrough time; b: Steady state permeation rate; c: Calculated diffusion coefficient; d: µg/cm2; e: Permeation rate over 8 h µg/cm2. 2-EE: 2-ethoxyethanol; 2-BE: 2-butoxyethanol.