Literature DB >> 31685396

Midterm Outcomes and Frequency of Osteolysis of Total Hip Arthroplasty Using Cementless Modular Stem for Asian Patients.

Atsuko Sato1, Naoki Okuda1, Sachiyuki Tsukada2, Akimasa Kimura1, Masanori Kase1, Masaaki Matsubara1.   

Abstract

BACKGROUND: Modular stems are useful for total hip arthroplasty (THA) in anatomically difficult dysplasia. Here, we present mean 6.8-year outcomes of cementless primary THA using S-ROM-A (modified modular stem for Asian patients) femoral prosthesis in anatomically difficult cases.
METHODS: Charts of 373 patients (461 hips) undergoing THA (mean age, 58 years) were reviewed for clinical evaluation of modified Merle d'Aubigné-Postel score and Kaplan-Meier survivorship with revision for any reason as the end point. For radiographic analysis, 331 patients (412 hips) followed up for ≥5 years were included. Bearing couples were metal-on-metal (n = 145), metal-on-polyethylene (n = 120), and ceramic-on-polyethylene (n = 147). Radiography and multiplanar computed tomography were performed.
RESULTS: No postoperative dislocation or deep infection occurred. Mean modified Merle d'Aubigné-Postel score improved significantly (10.9 points preoperatively, 16.7 points at last follow-up; P < .001). Cumulative 5- and 10-year stem survival rates were 100% and 84%, respectively (95% confidence interval, 75%-93%). All stems were classified as bone ingrown fixation. Osteolysis occurred in metal-on-metal (42.8%) and metal-on-polyethylene (15.8%) groups. Mean time to osteolysis was ~3 years, with no significant difference between 3 groups (P = .264). In logistic regression, lower cup inclination angle was significantly associated with osteolysis (odds ratio, 0.914; 95% confidence interval, 0.84-0.99; P = .029).
CONCLUSION: S-ROM-A femoral prosthesis achieved excellent midterm fixation, and the modular system was useful in primary THA with severe deformity. Bearing couples are potentially associated with adverse reactions to metal debris. S-ROM-A with ceramic-on-polyethylene bearing couples may be an option for anatomically difficult THA.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  S-ROM-A; adverse reactions to metal debris; midterm outcomes; modular stem; osteolysis; total hip arthroplasty

Mesh:

Year:  2019        PMID: 31685396     DOI: 10.1016/j.arth.2019.10.018

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  2 in total

1.  Mid-term outcomes of the Wagner Cone Prosthesis™ stem for developmental dysplasia of the hip: minimum two year follow-up.

Authors:  Anser Daud; Ryan Perlus; Amit Anand; Oleg A Safir; Allan E Gross; Paul R Kuzyk
Journal:  Int Orthop       Date:  2022-05-20       Impact factor: 3.479

2.  Higher incidence of aseptic loosening caused by a lower canal filling ratio with a modified modular stem in total hip arthroplasty.

Authors:  Kyosuke Kobayashi; Kenichi Kidera; Masaru Itose; Tetsuhiko Motokawa; Ko Chiba; Makoto Osaki
Journal:  J Orthop Surg Res       Date:  2020-11-30       Impact factor: 2.359

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.