Literature DB >> 31679579

High specificity and efficiency electrochemical detection of poly(ADP-ribose) polymerase-1 activity based on versatile peptide-templated copper nanoparticles and detection array.

Zhuang Wang1, Ensheng Xu1, Chenchen Wang1, Wei Wei2, Yong Liu3, Songqin Liu1.   

Abstract

Poly(ADP-ribose) polymerase-1 (PARP-1) activity is closely related to tumor, which is a promising biomarker for cancer diagnosis. So far, only a few methods have been developed for PARP-1 activity assay because both PARP-1 and its catalytic products lack valuable optical or electrochemical property. Herein, we propose a more specific method to label probes on great deal of phosphate groups of PAR. Firstly, versatile peptides were used to prepare CuNPs. This peptide not only worked as reducing agent to prepare CuNPs but also had guanidine groups to label PAR autonomously and specifically. Unlike most previously reported methods based on unspecific electrostatic interactions, CuNPs probes covered by guanidine groups labelled PAR with phosphate groups via intense covalent-like interactions. On the other hand, PARP-1 catalyzed the formation of PAR in each isolated reaction container of the detection array, realizing the high-throughput detection and enhancing the detection efficiency. Ultimately, CuNPs were oxidized into Cu2+ and precisely detected by stripping voltammetry. Hence, selectivity and efficiency of PARP-1 detection were both improved. Meanwhile, this approach was successfully used to detect the efficiency of PARP-1 inhibitor and the PARP-1 contents in real cells, indicating its great potential for clinical diagnosis and high-throughput PARP-1 inhibitor screen.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Covalent-like interaction; Detection array; Guanidine groups; Peptide-templated CuNPs; Poly(ADP-ribose) polymerase-1; Stripping voltammetry

Mesh:

Substances:

Year:  2019        PMID: 31679579     DOI: 10.1016/j.aca.2019.09.023

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

Review 1.  Electrochemical nanobiosensors equipped with peptides: a review.

Authors:  Masoud Negahdary; Lúcio Angnes
Journal:  Mikrochim Acta       Date:  2022-02-08       Impact factor: 5.833

Review 2.  The Role of Peptides in the Design of Electrochemical Biosensors for Clinical Diagnostics.

Authors:  Patrick Severin Sfragano; Giulia Moro; Federico Polo; Ilaria Palchetti
Journal:  Biosensors (Basel)       Date:  2021-07-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.