Literature DB >> 31673857

Chairside measurement of the marginal and internal fit of crowns: a new intraoral scan-based approach.

Maximiliane Amelie Schlenz1, Jonas Adrian Helmut Vogler2, Alexander Schmidt2, Peter Rehmann2, Bernd Wöstmann2.   

Abstract

OBJECTIVES: To investigate the marginal and internal fit of crowns, a new intraoral scanner-based digital approach for chairside measurement (D-IOS) was systematically analysed and compared with the conventional silicone replica technique (CV-SR) and digital 3D analysis software (D-GOM).
MATERIALS AND METHODS: Two models, representing different clinical situations, were constructed, and the first molar was prepared for a full-coverage crown. On the basis of an intraoral scan (Trios 3), copings of three different materials (non-precious alloy, zirconium dioxide, and resin composite) with two different cement spaces (80 μm, 50 μm) were manufactured. The fit of the copings was investigated by all three methods (CV-SR, D-IOS, D-GOM). Therefore, the cement space was visualized with low-viscosity silicone and digitalized with a second intraoral scan. Evaluation of fit by the D-IOS-method was measured in the intraoral scanner software, whereas for analysis by D-GOM, both intraoral scan datasets were transferred to 3D analysis software (GOM Inspect). The CV-SR-method was used as a control group. For all copings, the measurements were repeated five times. The data were analysed with ANOVA.
RESULTS: No significant differences between the three evaluation methods and the coping materials were shown. However, in the occlusal area, the internal gap was significantly higher compared to the internal gap in the marginal and axial areas regardless of the cement space setting (p < .05). The target parameter of the cement spaces did not match the actual measured internal gaps.
CONCLUSIONS: All three evaluation methods and coping materials can be used for the measurement of fit within different clinical situations. CLINICAL RELEVANCE: The digital chairside measurement implemented in the intraoral scanner software enables an easy, applicable evaluation of fit of crowns without additional laboratory devices or special software applications.

Entities:  

Keywords:  CAD/CAM; Chairside; Internal fit; Intraoral scanner; Marginal fit; Replica technique

Mesh:

Year:  2019        PMID: 31673857     DOI: 10.1007/s00784-019-03108-3

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  2 in total

1.  New Intraoral Scanner-Based Chairside Measurement Method to Investigate the Internal Fit of Crowns: A Clinical Trial.

Authors:  Maximiliane Amelie Schlenz; Jonas Vogler; Alexander Schmidt; Peter Rehmann; Bernd Wöstmann
Journal:  Int J Environ Res Public Health       Date:  2020-03-25       Impact factor: 3.390

2.  New Caries Diagnostic Tools in Intraoral Scanners: A Comparative In Vitro Study to Established Methods in Permanent and Primary Teeth.

Authors:  Maximiliane Amelie Schlenz; Berenike Schupp; Alexander Schmidt; Bernd Wöstmann; Ingo Baresel; Norbert Krämer; Nelly Schulz-Weidner
Journal:  Sensors (Basel)       Date:  2022-03-10       Impact factor: 3.576