Hiatal Surface Area's CT scan measurement is useful in hiatal hernia's treatment of bariatric patients.

Cristian E Boru1, Marco Rengo2, Angelo Iossa1, Francesco De Angelis1, Matteo Massaro1, Alessandra Spagnoli3, Anna Guida1, Andrea Laghi2, Gianfranco Silecchia1.   

Abstract

INTRODUCTION: Hiatal surface area (HSA) measurement has been recently proposed as useful tool for tailored treatment of hiatal defects. Multidetector CT scan (MDCT) of the hiatal area was shown to be useful in hiatal hernia (HH) management.
PURPOSE: MDCT preoperative HSA measurements validation as a useful method in the surgical repair decision making process of hiatal defects in candidates to antireflux ± bariatric surgery.
MATERIAL AND METHODS: Twenty-five obese patients (group A), candidates to laparoscopic cruroplasty ± bariatric surgery, were prospectively evaluated preoperatively and after one year, using an original MDCT algorithm, compared with intraoperative HSA measurement. Twelve non-obese (group B) and 12 obese patients (group C), without GERD or HH, were used as control groups.
RESULTS: Median preoperative HSA was 7.9 cm2, (interquartile IQR 5.97-9.80) while intraoperative median HSA was 6 cm2 (6-9.5), p = .84. Postoperative median HSA was 3.8 cm2 (3.21-4.8), showing the efficacy of cruroplasty, comparable with HSA calculated in the control groups (3.98 for B and 3.69 cm2 for C, p = .8547). No statistically significant difference between MDCT preoperative measurement and intraoperative findings was observed.
CONCLUSIONS: Preliminary results demonstrate MDCT scan HSA measurements as a valid, non-invasive method to predict intraoperative findings. It allows the HSA monitoring in order to correlate the symptoms onset and failure of cruroplasty.

Entities:  

Keywords:  Hiatal surface area HSA; MDCT scan; bariatric surgery; hiatal hernia; posterior cruroplasty

Mesh:

Year:  2019        PMID: 31671007     DOI: 10.1080/13645706.2019.1683033

Source DB:  PubMed          Journal:  Minim Invasive Ther Allied Technol        ISSN: 1364-5706            Impact factor:   2.442


  3 in total

1.  The effect of age and sex on esophageal hiatal surface area among normal North American adults using multidetector computed tomography.

Authors:  C Dass; G Dass; S Fisher; J Litvin
Journal:  Surg Radiol Anat       Date:  2022-05-24       Impact factor: 1.246

2.  Preoperative measurement of the hiatal surface with MDCT: impact on surgical planning.

Authors:  Marco Rengo; Cristian E Boru; Stefano Badia; Angelo Iossa; Davide Bellini; Simona Picchia; Nicola Panvini; Iacopo Carbone; Gianfranco Silecchia; Andrea Laghi
Journal:  Radiol Med       Date:  2021-08-27       Impact factor: 3.469

3.  Measurement of hiatal surface area and other hiatus oesophageal diameters at computed tomography imaging in patients with gastroesophageal reflux disease and its relationship with hiatal hernia.

Authors:  Emrah Karatay; Mehmet Ali Gok; Mirkhalig Javadov
Journal:  J Minim Access Surg       Date:  2021 Oct-Dec       Impact factor: 1.407

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.