Indoor Culturable Fungal Load and Associated Factors among Public Primary School Classrooms in Gondar City, Northwest Ethiopia, 2018: A Cross-sectional Study.

Zewudu Andualem1, Zemichael Gizaw1, Henok Dagne1.   

Abstract

BACKGROUND: Fungi are heavy threats to public health in indoor environments, particularly in residential buildings, offices, and schools where people spend a lot of time indoors. This study was conducted to investigate the load of culturable fungi and associated factors in a school indoor environment.
METHODS: Institutional based cross-sectional study was conducted in eight public primary school classrooms in Gondar City from March to April 2018. Settle plate technique was used to determine the culturable fungal load. Log transformed linear regression analysis was employed. The beta-coefficient with a 95% confidence interval was used to determine the degree and direction of the association with a p-value less than 0.05.
RESULTS: The highest and the lowest mean culturable fungal loads recorded were 1140.29 CFU/m3 and 211.25 CFU/m3, respectively. Aspergillus, Mucor, Penicillium, Candida, Microsporum, Trichophyton, Rhizopus, Alternaria and Fusarium species were isolated. Age of buildings (β= -0.122, 95%CI -0.238,-0.007), area of classroom (β= 0.639, 95% CI 0.285, 0.993), temperature (β= -0.189, 95% CI -0.325,-0.047), humidity (β= -0.023, 95% CI -0.043, -0.002) and PM10 (β= -0.01, 95% CI -0.015,-0.005) were associated with culturable fungal load.
CONCLUSIONS: High culturable fungal load was found in school classrooms in Gondar City. Age of buildings, area of classrooms, temperature, humidity, and PM10 were predictors of the culturable fungal load. Therefore, proficient corrective methods are needed to combat the problem of indoor air quality in a school indoor environment by controlling factors contributing to growth of fungi. ©2019 Zewudu Andualem, et al.

Entities:  

Keywords:  Gondar City; School indoor air; culturable fungal load; settles plate technique

Mesh:

Year:  2019        PMID: 31666784      PMCID: PMC6813266          DOI: 10.4314/ejhs.v29i5.13

Source DB:  PubMed          Journal:  Ethiop J Health Sci        ISSN: 1029-1857


Introduction

Indoor air quality is a foremost important factor affecting the health and well-being of people who inhale a minimum of 10–14m3 of the air daily and spend between 80–95% of their lives indoors (1,2). The air inhaled by individuals is profusely inhabited with microorganisms called bioaerosols(3). Bioaerosols are colloids, shaped by liquid droplets and particles of solid matter within the air, whose elements contain viruses, fungal spores, and conidia, plant pollen and fragments of plant tissues (3,4). Indoor air contamination is a health hazard as people spend much time in homes, offices and densely populated areas like schools (5). In 2016, WHO reported that globally, 3.8 million deaths were attributed to indoor air pollution. More than 90% of air pollution-related deaths occur in lowand middle-income countries, mainly in Asia and Africa, followed by low and middle-income countries of the Eastern Mediterranean region, Europe and Americas (5). Fungi are present everywhere and are a significant threat to public health in indoor environments (6,7). They are able to grow on most natural and synthetic materials, particularly absorptive or wet and inorganic materials get settled as they absorb dirt and function sensible growth substrates for Aspergillus fumigatus and Aspergillus versicolor (7). Fungal species like Cladosporium and Penicillium (Penicillium brevicompactum and Penicillium expansum) infest building materials and highly attack wood (8). Biotic pollutants of the indoor air include fungi, bacteria, viruses, pollen, etc. Fungi are able to grow wherever there are moisture and organic substrates. Building materials like ceiling tiles, wood, paint, carpet rugs, etc., are a very good setting for the growth of fungi (9). Potential sources of biotic pollutants of indoor air comprise people, organic dust, various materials stored in buildings, and also the air influent from the ventilation and air conditioning systems (10). About 2–6% of the overall population in developed countries is allergic to fungi, and the higher susceptibility is distinguished concerning genera of Alternaria, Cladosporium, Aspergillus, Penicillium and Fusarium (11). Exposure to fungi has been reported to cause several types of human health problems, primarily irritations, infections, allergies and toxic effects, and it has been suggested that toxigenic fungi are the cause of additional adverse health effects (12). Adverse health effects are supposed to be linked with microbial growth in indoor areas and is mostly related with mold growth. Allergies are a predominant condition to be mentioned, followed by toxic alveolitis and reactions like (allergic) bronchitis, chronic obstructive pulmonary disease, and aggravation of asthma. Mold and bacterial infections are very rare, but people with immunodeficiency are particularly prone to fungal infections (13). It has been found that spores of fungi contain fungal toxins (mycotoxins), which are well known from food contaminations (13). However, their load and contributing factors in the school indoor environment is not well investigated in Ethiopia. This study was, therefore, conducted to assess the indoor culturable fungal load and its associated factors among school classrooms in Gondar City, Northwest Ethiopia.

Materials and Methods

Study design and study area: Institutional based cross-sectional study was conducted to assess indoor culturable fungal load and its associated factors in public primary school classrooms in Gondar City, Northwest Ethiopia. The details of the method (study setting, sample size determination, and sampling technique) are presented well elsewhere (14). Assessment of the physical characteristics of classrooms: Structured checklist was used to assess factors associated with the indoor culturable fungal load, such as the age of buildings, condition of the buildings, construction status, window safety conditions, cross-ventilation, area of classroom (m2), classroom cleaning frequency, and a number of windows. Physical parameters like PM2.5, PM10, temperature, humidity and carbon dioxide concentration in the classrooms were measured by using Airveda. Aireveda is an instrument used to measures PM2.5, PM10, CO2, temperature and humidity. It monitors use of high quality laser sensors, calibrated individually for Indian conditions against BAM (Beta Attenuation Monitor- the most advanced system for measuring ambient air quality). This device contains a high quality NDIR CO2 sensor, which allows the user to easily self-calibrate, ensuring the best results. Temperature and humidity sensors are calibrated by a master source traceable to NABL (15). Air sampling procedures: Air samples were taken from fifty-one randomly selected classrooms of eight public primary schools in Gondar city. Passive air sampling method i.e., the settle plate method was used. Standard Petri dishes with 9 cm diameter (63.585 cm2 areas) containing culture media were exposed. Fungalload was determined was based on the count of the microbial falls out on to Petri dishes left open to the air according to the 1/1/1 scheme (for 1 hour, 1m from the floor, at least 1 meter away from walls or any obstacle) (16,17). Fungi were collected on Sabouraud dextrose agar (SDA) media to which an antibacterial agent (Chloramphenicol) has been added to inhibit the growth of bacteria. Sampling was done in the morning (at 6:30 am, before students entered the classroom) and afternoon (5:00 pm, after students left the classroom) to determine the fungal concentration with respect to environmental variation. After exposure, the samples were taken to the laboratory (Department of Biology, at the University of Gondar) and incubated at 25 °C for 3 to 5 days. Sterile gloves, mouth masks, and protective gown were worn to avoid contamination of agar plates during air sampling and analysis. Openings like doors and windows were closed to minimize dilution of air contaminants (3,18,19). Moreover, the movement of individuals throughout sampling was restricted to avoid air disturbance and lately emitted microorganisms. The agar plates were also checked visually before use for any microbial growth. Colony Forming Units (CFU) were enumerated and the load was determined using the following equation(20). Where: N = microbial CFU/m3 of indoor air; a = number of colonies per Petri dish; b = dish surface area (cm2); t = exposure time (minute). Fungal isolation was identified on the basis of microscopic (using Lactophenol cotton blue staining) and macroscopic characteristics (with the aid of an Atlas of Mycology) (21, 22). Data analysis: Statistical analysis was carried out with Kruskal-Wallis H test using Stata/SE software version 14.0 to know the mean fungal load difference between public primary schools. Log transformed linear regression was used to determine the relationship between mean fungal loads with independent variables. Statistically significant variables were identified on the basis of the beta coefficient with 95% confidence interval and a pvalue less than 0.05.

Results

Socio-demographic characteristics: A total of 2722 students were attending classes in fifty-one randomly selected classrooms in eight public primary schools. A quarter (25.49%) and three-fourths (74.51%) of the students were aged 5–11 and 12–19 years, respectively. The mean number of students per classroom was 53.37 ± (SD = 14.37). Building and environmental sanitation information: From a total of 51 classrooms, 19(37.25%) classrooms were constructed from mud and wood, and 32(62.75%) from bricks (Table 1).
Table 1

The building, sanitation and environmental related information of public primary school classrooms in Gondar city, Northwest Ethiopia, 2018

VariablesFrequency%
Age of buildings
≥ 18 yr.1937.25
< 18 yr.3262.75
Number of windows
Low11.96
Average713.73
High4384.31
Allows cross ventilation
Yes4486.27
No713.73
Area of classroom
30–64 m23262.75
≥ 64 m21937.25
Cleaning frequency of classroom
Once a week3568.63
Two times a week1631.37
Condition of the buildings
Low3568.63
Average1325.49
High35.88
Construction status
Low1325.5
Average2956.49
High917.86
Window safety condition
Low2752.94
Average2039.22
High47.84
The building, sanitation and environmental related information of public primary school classrooms in Gondar city, Northwest Ethiopia, 2018 Culturable fungal load in the school indoor environment: The lowest and the highest mean fungal loads were recorded at school 6 and school 2 as 211.25CFU/m3 and 1140.29CFU/m3, respectively. The total mean fungal load was 613.29 CFU/m3 (Table 2).
Table 2

Statistical summary of mean fungal load in eight public primary school classrooms in Gondar city, Northwest, Ethiopia 2018

Name of SchoolNumber of ClassroomsMean fungal loadStandard deviationMedianMinimumMaximum
School 15669.570.608676598767
School 271140.29530.7081157591.52164.5
School 33613.1730.719624578.5637
School 48468.8161.707471.25364546
School 57382.5772.617377253.5494
School 68211.2567.906214.5136.5299
School 771104.07182.4801118916.51417
School 8637780.977396.5273455
Total51613.29396.195487.5136.52164.5
Statistical summary of mean fungal load in eight public primary school classrooms in Gondar city, Northwest, Ethiopia 2018 Fungal species were identified from the culture, and the result showed that Trichophyton species were found in all public primary schools while Aspergillus species were found in seven of the eight schools (Table 3). According to the sanitary standards for non-industrial premises, the degree of air pollution by fungal population across the various classrooms ranges largely between intermediate to high (Table 4).
Table 3

Type of microorganism isolated from each public Primary school classrooms in Gondar city, Northwest Ethiopia, 2018

Isolated Fungi

Name of SchoolASMUPECATRRHMSALFU
School 1+-+++----
School 2++++++-++
School 3+++++---+
School 4+++-+-+++
School 5+--++--+-
School 6+--++++++
School 7----+--++
School 8+---+++++

KEYS: + = Present, - = absent. AS = Aspergillus species, MU = Mucor species, PE = Penicillium species, CA = Candida species, MS = Microsporium species, TR = Trichophyton species, RH = Rhizopus species, AL = Alternaria species, FU = Fusarium species

Table 4

Assessment of indoor culturable fungal load according to the sanitary standards for non- industrial premises in public Primary school classrooms Northwest Ethiopia, 2018

Sampling time6:30–7:30 am5:00–6:00 pm

Range of values(CFU/m3)<2525–100100–500500–2000>2000<2525–100100–500500–2000>2000

Degree of Air PollutionVery lowLowIntermediateHighVery highVery lowLowIntermediateHighVery high
School 1
School 2
School 3
School 4
School 5
School 6
School 7
School 8

NB: ≤ 500 CFU/m3 is the permissive standard, (✓) in the range

Type of microorganism isolated from each public Primary school classrooms in Gondar city, Northwest Ethiopia, 2018 KEYS: + = Present, - = absent. AS = Aspergillus species, MU = Mucor species, PE = Penicillium species, CA = Candida species, MS = Microsporium species, TR = Trichophyton species, RH = Rhizopus species, AL = Alternaria species, FU = Fusarium species Assessment of indoor culturable fungal load according to the sanitary standards for non- industrial premises in public Primary school classrooms Northwest Ethiopia, 2018 NB: ≤ 500 CFU/m3 is the permissive standard, (✓) in the range Kruskal-Wallis H test was conducted to obtain the mean fungal load difference among public primary schools as presented below. The highest mean fungal load, 1140.28 CFU/m3, in school 2 and the lowest, 211.25 CFU/m3, concentration in school 6 was recorded. The grand total mean fungal load was 613.29 CFU/m3. The Kruskal-Wallis H test showed that there was a significant mean fungal load difference in public primary schools (X2 = 44.82, df = 7 and p = 0.0001). Factors associated with the mean indoor culturable fungal load: The results of the current study showed that the mean fungal load was significantly associated with age of buildings, indoor temperature, indoor humidity, PM10 and area of classroom (Table 5).
Table 5

Factors associated with the mean fungal load in public primary school classrooms in Gondar city, Northwest Ethiopia, 2018

Variablesβ CoefficientStd. ErrP - value[95% CI for β]

LU
Age of buildings-.122.0590.038*-.238-.007
Area of classroom.639.1810.000**.285.993
Mean CO2-.0002.0050.962-.009.009
Mean T °C-.186.0710.008*-.325-.047
Mean humidity-.023.0110.033*-.043-.002
No of windows.477.5640.398-.6291.583
Allow cross ventilation-.395.8580.645-2.071.287
Mean PM10-.010.0030.000**-.015-.005
Cleaning frequency of classroom.168.1730.332-.171.507
Safety Condition of windows-.133.1130.238-.354.088
Wall construction-.129.2380.586-.595.336
_cons9.7532.090.0005.65613.85

* = Significant association **= p<0.001 *= p< 0.05

Factors associated with the mean fungal load in public primary school classrooms in Gondar city, Northwest Ethiopia, 2018 * = Significant association **= p<0.001 *= p< 0.05 New age buildings had 12.2% lower fungal load than old age buildings (β= -0.122, 95% CI -0.238, -0.007). Classrooms with small areas had 63.9% higher fungal load than Classrooms with large areas (β= 0.639, 95% CI 0.285, 0.993). With one unit increase in the indoor temperature, the mean fungal load declines by 0.186 units (β=-0.186, 95%CI-0.325, -0.047). With one unit increase in the indoor humidity, the mean fungal load declines by 0.023 units (β= -0.023, 95% CI -0.043, -0.002). A 100% increase in the PM10 concentration will reduce the mean fungal load by 1% (β= -0.01, 95% CI -0.015,-0.005).

Discussion

The fungal load ranged from 52-3900 CFU/m3 with the total mean fungal load being 613.29 CFU/m3 in school classrooms of Gondar City. The result of this study was lower than the result of a study conducted in Portugal (1164 CFU/m3)(23). On the contrary, the mean fungal load recorded in this study was found to be higher than the report of a study in Malaysia (292 CFU/m3) (24). The variation of mean fungal load indoor environments might be due to environmental factors such as building condition, window safety condition, and construction status, the ventilation system of the classroom, temperature, humidity, and particulate matter concentration. Nine fungal species were isolated which included Aspergillus, Mucor, Penicillium, Candida, Microsporum, Trichophyton, Rhizopus, Alternaria and Fusarium species. The distribution of isolated fungal species in this study agreed with the works of Hussin N. et'al, (24) and Naruka K. et'al, (25). The study conducted by a WHO expert group on the assessment of health risks of biological agents in indoor environments recommended that total microbial concentration should not exceed 1000 CFU/m3(26). In healthy buildings, ≤ 750 CFU/m3 was the limit for fungi where species were not infectious (27). According to the sanitary standards of the European Commission for non-industrial premises, the permissible limits of fungal load was ≤ 500 CFU/m3(28). Due to the absence of generally accepted threshold limit values regarding concentrations of the air of indoor fungi, the obtained results could be compared solely with the values suggested by various authors or institutions. In this study, age of the building had a significant association with the airborne fungal load. This is in agreement with studies conducted in Iraq (29), India (25), and Nigeria (19). The possible explanation might be the fact that buildings with new-age contain low moisture content than old age buildings that can affect fungal load. Indoor fungal contamination during major demolition-construction work might help to detect increased fungal loads (30). Area of the classroom was significantly associated with fungal load. The possible explanation might be the fact that a large area of the classroom allows better ventilation thereby reducing the fungal load (31). In this study, temperature was negatively associated with the airborne fungal load. This finding agrees with a study conducted in India (25). The significant association between temperature with indoor airborne fungal load was not consistent with what is expected since a positive correlation between fungal load and temperature was already reported (32). The possible explanation for the negative association might be the effects of temperature on settling velocity of microbes into the plate and the impact of other natural and artificial factors that may carry an abundant variety of fungal load in school classrooms (33). In this study, humidity was negatively associated with the airborne fungal load. The negative association between relative humidity with indoor airborne fungal load was not consistent with what is expected since a positive association between fungal load and relative humidity was already reported (25,34). It requires further investigation to know the reason for the negative association between humidity and indoor air fungal load. PM10 concentration was significantly associated with fungal load. This is in agreement with a study conducted in the USA (35). However, in another study, particulate matter was not associated with fungal load (33). This might be explained as PM10 distribution is affected by temperature and humidity. In conclusion, a high fungal load was found in school classrooms in Gondar City compared with sanitary standards of the European Commission for non-industrial premises indoor air biological standards. Age of buildings, area of classrooms, temperature, humidity and concentration of particulate matters in classrooms were associated with indoor fungal load. Aspergillus, Mucor, Penicillium, Candida, Microsporum, Trichophyton, Rhizopus, Alternaria and Fusarium species were the commonly isolated fungi. As a result, proficient corrective methods are needed to combat the problem of indoor air quality in a school indoor environment by controlling the factors contributing to growth of fungi.
  15 in total

Review 1.  The index of microbial air contamination.

Authors:  C Pasquarella; O Pitzurra; A Savino
Journal:  J Hosp Infect       Date:  2000-12       Impact factor: 3.926

2.  Profiles of airborne fungi in buildings and outdoor environments in the United States.

Authors:  Brian G Shelton; Kimberly H Kirkland; W Dana Flanders; George K Morris
Journal:  Appl Environ Microbiol       Date:  2002-04       Impact factor: 4.792

3.  Microbial air contamination in indoor environment of a university library.

Authors:  Agnieszka Kalwasińska; Aleksandra Burkowska; Iwona Wilk
Journal:  Ann Agric Environ Med       Date:  2012       Impact factor: 1.447

Review 4.  Indoor environments and health: moving into the 21st century.

Authors:  Jonathan M Samet; John D Spengler
Journal:  Am J Public Health       Date:  2003-09       Impact factor: 9.308

Review 5.  Review of quantitative standards and guidelines for fungi in indoor air.

Authors:  C Y Rao; H A Burge; J C Chang
Journal:  J Air Waste Manag Assoc       Date:  1996-09       Impact factor: 2.235

6.  Chamber bioaerosol study: outdoor air and human occupants as sources of indoor airborne microbes.

Authors:  Rachel I Adams; Seema Bhangar; Wilmer Pasut; Edward A Arens; John W Taylor; Steven E Lindow; William W Nazaroff; Thomas D Bruns
Journal:  PLoS One       Date:  2015-05-29       Impact factor: 3.240

7.  High bacterial load of indoor air in hospital wards: the case of University of Gondar teaching hospital, Northwest Ethiopia.

Authors:  Zemichael Gizaw; Mulat Gebrehiwot; Chalachew Yenew
Journal:  Multidiscip Respir Med       Date:  2016-07-05

8.  Microbiota and Particulate Matter Assessment in Portuguese Optical Shops Providing Contact Lens Services.

Authors:  Carla Viegas; Tiago Faria; Cátia Pacífico; Mateus Dos Santos; Ana Monteiro; Carla Lança; Elisabete Carolino; Susana Viegas; Sandra Cabo Verde
Journal:  Healthcare (Basel)       Date:  2017-05-15

Review 9.  The role of fungi in allergic diseases.

Authors:  Wioletta A Zukiewicz-Sobczak
Journal:  Postepy Dermatol Alergol       Date:  2013-02-20       Impact factor: 1.837

10.  Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools.

Authors:  Zewudu Andualem; Zemichael Gizaw; Laekemariam Bogale; Henok Dagne
Journal:  Multidiscip Respir Med       Date:  2019-01-22
View more
  1 in total

1.  Passive air sampling: the use of the index of microbial air contamination.

Authors:  Isabella Viani; Maria Eugenia Colucci; Massimiliano Pergreffi; Deanna Rossi; Licia Veronesi; Assunta Bizzarro; Emanuela Capobianco; Paola Affanni; Roberta Zoni; Elisa Saccani; Roberto Albertini; Cesira Pasquarella
Journal:  Acta Biomed       Date:  2020-04-10
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.