Literature DB >> 31664671

Study on performance of electrostatic precipitator under multi-physics coupling.

Bing Chen1, Hongjiao Li2, Yuzhong He3, Baiqian Liu2, Lijie Zhang2.   

Abstract

A wire-plate electrostatic precipitator (ESP) is developed to analyze the particle transport characteristics and the influence of various factors on the performance of ESP. Above all, an experimental device is built to measure the current density distribution of the plates and obtain good consistency with the numerical simulation results, taking the ESP model established by COMSOL/Multiphysics as the numerical simulating object. Firstly, the electric field is solved by finite element method(FEM) to obtain the potential and charge density distribution. Then, the influence of secondary flow on the main flow at different flow velocities is explored. Finally, multi-physics coupling calculations show the influence of dust particle properties, electrode configuration, and operating conditions on ESP performance. The study found that the particle diameter is positively correlated with its charge, force, and motion, and the relative permittivity of the particles affects the collecting efficiency by affecting its charge difficulty. The wire-to-wire spacing is not proportional to collecting efficiency, when the spacing is 80 mm, the efficiency and the corona current can be maximized. Average electric field strength, corona current density, and current density distribution standard deviation satisfy the cubic function relationship. In addition, the effect of airflow velocity on collecting efficiency and particle precipitation is revealed. It provides a valuable basis for design and performance optimization of ESP.

Keywords:  Collecting efficiency; Corona discharge; Electrode configuration; Electrostatic precipitator; Ionic wind; Particle transport; Secondary flow

Mesh:

Substances:

Year:  2019        PMID: 31664671     DOI: 10.1007/s11356-019-06623-8

Source DB:  PubMed          Journal:  Environ Sci Pollut Res Int        ISSN: 0944-1344            Impact factor:   4.223


  3 in total

1.  Effects of coal blending in electrostatic precipitation efficiency-Inner Mongolia, China.

Authors:  Liqiang Qi; Jun Xu; Yuan Yao; Yajuan Zhang
Journal:  Environ Sci Pollut Res Int       Date:  2018-09-08       Impact factor: 4.223

2.  Emissions of sulfur trioxide from coal-fired power plants.

Authors:  R K Srivastava; C A Miller; C Erickson; R Jambhekar
Journal:  J Air Waste Manag Assoc       Date:  2004-06       Impact factor: 2.235

Review 3.  Risk of human health by particulate matter as a source of air pollution--comparison with tobacco smoking.

Authors:  Makoto Enomoto; William J Tierney; Kohsuke Nozaki
Journal:  J Toxicol Sci       Date:  2008-08       Impact factor: 2.196

  3 in total