Literature DB >> 31664570

Neural cell responses to wear debris from metal-on-metal total disc replacements.

H Lee1, J B Phillips2, R M Hall1, Joanne L Tipper3,4.   

Abstract

PURPOSE: Total disc replacements, comprising all-metal articulations, are compromised by wear and particle production. Metallic wear debris and ions trigger a range of biological responses including inflammation, genotoxicity, cytotoxicity, hypersensitivity and pseudotumour formation, therefore we hypothesise that, due to proximity to the spinal cord, glial cells may be adversely affected.
METHODS: Clinically relevant cobalt chrome (CoCr) and stainless steel (SS) wear particles were generated using a six-station pin-on-plate wear simulator. The effects of metallic particles (0.5-50 μm3 debris per cell) and metal ions on glial cell viability, cellular activity (glial fibrillary acidic protein (GFAP) expression) and DNA integrity were investigated in 2D and 3D culture using live/dead, immunocytochemistry and a comet assay, respectively.
RESULTS: CoCr wear particles and ions caused significant reductions in glial cell viability in both 2D and 3D culture systems. Stainless steel particles did not affect glial cell viability or astrocyte activation. In contrast, ions released from SS caused significant reductions in glial cell viability, an effect that was especially noticeable when astrocytes were cultured in isolation without microglia. DNA damage was observed in both cell types and with both biomaterials tested. CoCr wear particles had a dose-dependent effect on astrocyte activation, measured through expression of GFAP.
CONCLUSIONS: The results from this study suggest that microglia influence the effects that metal particles have on astrocytes, that SS ions and particles play a role in the adverse effects observed and that SS is a less toxic biomaterial than CoCr alloy for use in spinal devices. These slides can be retrieved under Electronic Supplementary Material.

Entities:  

Keywords:  Cobalt chromium; Glial cells; Metal wear particles; Stainless steel; Total disc replacements (TDR)

Mesh:

Substances:

Year:  2019        PMID: 31664570     DOI: 10.1007/s00586-019-06177-w

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  1 in total

1.  Biological Impact of Silicon Nitride for Orthopaedic Applications: Role of Particle Size, Surface Composition and Donor Variation.

Authors:  Saurabh Lal; Emily A Caseley; Richard M Hall; Joanne L Tipper
Journal:  Sci Rep       Date:  2018-06-14       Impact factor: 4.379

  1 in total
  2 in total

Review 1.  Recent Advances in Managing Spinal Intervertebral Discs Degeneration.

Authors:  Bogdan Costăchescu; Adelina-Gabriela Niculescu; Raluca Ioana Teleanu; Bogdan Florin Iliescu; Marius Rădulescu; Alexandru Mihai Grumezescu; Marius Gabriel Dabija
Journal:  Int J Mol Sci       Date:  2022-06-09       Impact factor: 6.208

2.  Neurological emergency from rare spinal metalloma: Case report and literature review.

Authors:  David J Mazur-Hart; Erik W Larson; Nasser K Yaghi; Aaron M Halfpenny; David R Pettersson; David A Yam
Journal:  Radiol Case Rep       Date:  2022-03-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.