| Literature DB >> 31662357 |
Andrea Niederhauser1, Stephanie Züllig2, Jonas Marschall3,4, Alexander Schweiger3,5, Gregor John6, Stefan P Kuster3,7, David Lb Schwappach2,8.
Abstract
OBJECTIVE: To evaluate changes in staff perspectives towards indwelling urinary catheter (IUC) use after implementation of a 1-year quality improvement project.Entities:
Keywords: indwelling urinary catheter; intervention bundle; patient safety; perception; survey
Year: 2019 PMID: 31662357 PMCID: PMC6830685 DOI: 10.1136/bmjopen-2018-028740
Source DB: PubMed Journal: BMJ Open ISSN: 2044-6055 Impact factor: 2.692
Study sample characteristics
| T0 | T1 | P value* | |
| n=1579 | n=1527 | ||
| Participants per hospital, n (%)† | 0.385 | ||
| Hospital A (approximately 900 beds) | 221 (14.0) | 223 (14.6) | |
| Hospital B (approximately 800 beds) | 154 (9.8) | 170 (11.1) | |
| Hospital C (approximately 500 beds) | 138 (8.7) | 127 (8.3) | |
| Hospital D (approximately 500 beds) | 362 (22.9) | 325 (21.3) | |
| Hospital E (approximately 400 beds) | 347 (22.0) | 342 (22.4) | |
| Hospital F (approximately 300 beds) | 284 (18.0) | 250 (16.4) | |
| Hospital G (approximately 100 beds) | 73 (4.6) | 90 (5.9) | |
| Female, n (%) | 1187 (77.6) | 1191 (79.7) | 0.173 |
| Age in years, mean (SD) | 36.8 (10.5) | 35.9 (10.5) | 0.0255 |
| Profession, n (%) | 0.043 | ||
| Nurse | 1050 (69.1) | 1084 (72.8) | |
| Physician | 350 (23.0) | 288 (19.3) | |
| Other | 120 (7.9) | 117 (7.9) | |
| With managerial function, n (%) | 232 (16.4) | 193 (13.9) | 0.066 |
| Years working in this hospital, n (%) | 0.849 | ||
| <2 | 376 (24.5) | 380 (25.4) | |
| 2 to <5 | 385 (25.0) | 357 (23.9) | |
| 5 to <10 | 264 (17.2) | 271 (18.1) | |
| 10 to <20 | 307 (20.0) | 297 (19.9) | |
| ≥20 | 206 (13.4) | 190 (12.7) | |
| Work unit in the past 3 months, n (%) | 0.020 | ||
| Ward | 906 (58.5) | 963 (63.9) | |
| Emergency department | 248 (16.0) | 190 (12.6) | |
| Intensive care unit | 144 (9.3) | 129 (8.6) | |
| Operating room | 146 (9.4) | 141 (9.4) | |
| Other | 104 (6.7) | 85 (5.6) | |
| Overall experience with catheter placement throughout | 0.300 | ||
| Never | 26 (1.7) | 30 (2.0) | |
| 1–5 times | 169 (11.0) | 171 (11.4) | |
| 6–20 times | 341 (22.2) | 370 (24.6) | |
| >20 times | 1002 (65.2) | 931 (62.0) | |
| Frequency of catheter placement in current position, n (%) | 0.084 | ||
| Frequent user | 690 (44.2) | 618 (41.1) | |
| Infrequent user | 871 (55.8) | 885 (58.9) | |
Due to rounding percentages may not always add up to 100%.
T0: baseline survey; T1: follow-up survey.
Frequent user: places a catheter a few times a month or more often; infrequent user: places a catheter a few times a year or less often.
*P values for changes between the two time periods.
†In the larger hospitals, not all of the departments participated in the project.
Mean number of correct answers provided for 15 knowledge items
| MeanT 0 (95% CI) | nT0 | MeanT1 (95% CI) | nT1 | P value | Effect size | |
| Overall sample | 10.4 (10.3 to 10.5) | 1579 | 11.0 (10.9 to 11.1) | 1527 | <0.001 | 0.29 |
| Professional group | ||||||
| Nurses | 10.2 (10.1 to 10.4) | 1050 | 10.9 (10.8 to 11.0) | 1084 | <0.001 | 0.35 |
| Physicians | 11.1 (11.0 to 11.3) | 350 | 11.4 (11.2 to 11.6) | 288 | 0.047 | 0.16 |
| Managerial function | ||||||
| With | 11.3 (11.1 to 11.5) | 232 | 11.6 (11.4 to 11.9) | 193 | 0.058 | 0.19 |
| Without | 10.3 (10.1 to 10.4) | 1187 | 10.9 (10.8 to 11.0) | 1199 | <0.001 | 0.33 |
| Frequency of catheter placement | ||||||
| Frequent user | 10.0 (9.8 to 10.1) | 690 | 10.7 (10.6 to 10.9) | 618 | <0.001 | 0.40 |
| Infrequent user | 10.8 (10.7 to 10.9) | 871 | 11.2 (11.1 to 11.3) | 885 | <0.001 | 0.22 |
| Matched identification | 10.4 (10.3 to 10.6) | 420 | 11.3 (11.1 to 11.5) | 420 | <0.001 | 0.49 |
| Unmatched identification | 10.5 (10.3 to 10.6) | 1118 | 11.0 (10.9 to 11.1) | 1052 | <0.001 | 0.31 |
T0: baseline survey; T1: follow-up survey.
Frequent user: places a catheter a few times a month or more often; infrequent user: places a catheter a few times a year or less often.
Perception: mean scale score
| MeanT0 (95% CI) | nT0 | MeanT1 (95% CI) | nT1 | P value | Effect size | |
| Overall sample | 5.3 (5.3 to 5.3) | 1568 | 5.5 (5.5 to 5.6) | 1521 | <0.001 | 0.31 |
| Professional group | ||||||
| Nurses | 5.4 (5.3 to 5.4) | 1044 | 5.6 (5.6 to 5.7) | 1082 | <0.001 | 0.33 |
| Physicians | 5.1 (5.0 to 5.1) | 347 | 5.3 (5.2 to 5.4) | 286 | <0.001 | 0.29 |
| Managerial function | ||||||
| With | 5.2 (5.1 to 5.3) | 230 | 5.6 (5.5 to 5.7) | 191 | <0.001 | 0.52 |
| Without | 5.3 (5.3 to 5.4) | 1180 | 5.6 (5.5 to 5.6) | 1197 | <0.001 | 0.29 |
| Frequency of catheter placement | ||||||
| Frequent user | 5.2 (5.1 to 5.3) | 690 | 5.4 (5.3 to 5.5) | 618 | <0.001 | 0.22 |
| Infrequent user | 5.4 (5.3 to 5.4) | 861 | 5.7 (5.6 to 5.7) | 880 | <0.001 | 0.37 |
| Matched identification | 5.4 (5.3 to 5.4) | 416 | 5.6 (5.5 to 5.7) | 416 | <0.001 | 0.32 |
| Unmatched identification | 5.3 (5.2 to 5.3) | 1108 | 5.5 (5.5 to 5.6) | 1049 | <0.001 | 0.31 |
Scale consisted of 13 items. Items were answered on a scale from 1 (strongly disagree) to 7 (strongly agree). Cronbach’s alpha for the scale: T0 α=0.79 and T1 α=0.80.
T0: baseline survey; T1: follow-up survey.
Frequent user: places a catheter a few times a month or more often; infrequent user: places a catheter a few times a year or less often.
Figure 1Self-reported responsibilities in regard to urinary catheters by profession. *Change between time periods significant at p<0.05.
Determinants of behaviour: mean scale score
| MeanT0 (95% CI) | nT0 | MeanT1 (95% CI) | nT1 | P value | Effect size | |
| Overall sample | 5.3 (5.3 to 5.3) | 1539 | 5.6 (5.6 to 5.6) | 1502 | <0.001 | 0.43 |
| Professional group | ||||||
| Nurses | 5.3 (5.2 to 5.3) | 1046 | 5.6 (5.6 to 5.7) | 1083 | <0.001 | 0.56 |
| Physicians | 5.4 (5.3 to 5.5) | 349 | 5.6 (5.5 to 5.6) | 287 | 0.005 | 0.23 |
| Managerial function | ||||||
| With | 5.6 (5.5 to 5.7) | 230 | 5.8 (5.7 to 5.9) | 192 | <0.001 | 0.38 |
| Without | 5.2 (5.2 to 5.3) | 1184 | 5.6 (5.5 to 5.6) | 1198 | <0.001 | 0.50 |
| Frequency of catheter placement | ||||||
| Frequent user | 5.2 (5.2 to 5.3) | 675 | 5.6 (5.5 to 5.6) | 615 | <0.001 | 0.46 |
| Infrequent user | 5.3 (5.3 to 5.4) | 847 | 5.6 (5.6 to 5.7) | 884 | <0.001 | 0.41 |
| Matched identification | 5.3 (5.3 to 5.4) | 405 | 5.7 (5.6 to 5.8) | 405 | <0.001 | 0.58 |
| Unmatched identification | 5.3 (5.3 to 5.3) | 1090 | 5.6 (5.5 to 5.6) | 1038 | <0.001 | 0.37 |
Scale consisted of 15 items. Items were answered on a scale from 1 (strongly disagree) to 7 (strongly agree). Cronbach’s alpha for scale: T0 α=0.72 and T1 α=0.74.
T0: baseline survey; T1: follow-up survey.
Frequent user: places a catheter a few times a month or more often; infrequent user: places a catheter a few times a year or less often.