Literature DB >> 31659459

Correlation between 24-h continuous intraocular pressure measurement with a contact lens sensor and visual field progression.

Naoki Tojo1, Atsushi Hayashi2, Mitsuya Otsuka2.   

Abstract

PURPOSE: We investigated the correlations between 24-h continuous intraocular pressure (IOP) measurement with a contact lens sensor (CLS) and visual field (VF) progression.
METHODS: We examined 69 eyes of glaucoma patients who were followed > 2 years after the measurement of IOP fluctuation with a CLS. All patients underwent VF examinations > 4 times. VF progression was defined as a deterioration of the mean deviation (MD). We evaluated the original 17 parameters from the data obtained from the CLS output and attempted to identify which of them contributed to the VF progression. We then performed multivariate analyses to identify risk factors for rapid VF progression.
RESULTS: The mean follow-up period was 4.0 ± 1.6 years. The mean VF progression rate was - 0.37 ± 0.53 dB/year. The multivariate analysis identified the following as-risk factors for VF progression: more advanced baseline MD value (p = 0.0269); high maximum values during the 24-h (p = 0.0131) and nocturnal (p = 0.0466) periods; large standard deviation of IOP fluctuation during the 24-h (p = 0.0404), diurnal (p = 0.0330), and nocturnal (p = 0.0027) periods; and large range of IOP fluctuation during the nocturnal period (0.0431).
CONCLUSIONS: Our results suggested that the above CLS parameters might be correlated with rapid progression of VF disorder. These CLS parameters could be used to evaluate the results of CLS in the future. Examination with a CLS could be useful for predicting the VF progression rate within a mere 24-h period.

Entities:  

Keywords:  Contact lens sensor (CLS); Fluctuation; Intraocular pressure (IOP); Triggerfish; Visual field (VF)

Year:  2019        PMID: 31659459     DOI: 10.1007/s00417-019-04487-9

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  4 in total

1.  Association of Ambulatory Blood Pressure and Other Factors With Intraocular Pressure-Related 24-Hour Contact Lens Sensor Profile in Untreated Glaucoma.

Authors:  Kazuki Nakazawa; Tomomi Higashide; Shunsuke Tsuchiya; Satomi Shioya; Masahiko Okayama; Kazuhisa Sugiyama
Journal:  Transl Vis Sci Technol       Date:  2022-10-03       Impact factor: 3.048

2.  Home Self-tonometry Trials Compared with Clinic Tonometry in Patients with Glaucoma.

Authors:  Elyse J McGlumphy; Aleksandra Mihailovic; Pradeep Y Ramulu; Thomas V Johnson
Journal:  Ophthalmol Glaucoma       Date:  2021-04-09

3.  Inter-eye correlation analysis of 24-h IOPs and glaucoma progression.

Authors:  Mohamad Dakroub; Raoul Verma-Fuehring; Vaia Agorastou; Julian Schön; Jost Hillenkamp; Frank Puppe; Nils A Loewen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-05-02       Impact factor: 3.535

4.  HIOP-Reader: Automated Data Extraction for the Analysis of Manually Recorded Nycthemeral IOPs and Glaucoma Progression.

Authors:  Vaia Agorastou; Julian Schön; Raoul Verma-Fuehring; Mohamad Dakroub; Jost Hillenkamp; Frank Puppe; Nils A Loewen
Journal:  Transl Vis Sci Technol       Date:  2022-06-01       Impact factor: 3.048

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.