The aim of this study was to degrade theophylline (TP) drug in a pharmaceutical effluent solution utilizing persulfate (PS). A simulated and a real effluent solution were used, with different conditions tested to optimize the degradation process. HPLC analyses and a modified-HPLC method were used to track concentrations of TP and PS respectively in the treatment process. Experiments were done in triplicates and treated data is presented as graphs. A detailed analyses of this study can be found in the article "Degradation of theophylline in a UV254/PS system: matrix effect and application to a factory effluent" [1] published in Chemical Engineering Journal.
The aim of this study was to degrade theophylline (TP) drug in a pharmaceutical effluent solution utilizing persulfate (PS). A simulated and a real effluent solution were used, with different conditions tested to optimize the degradation process. HPLC analyses and a modified-HPLC method were used to track concentrations of TP and PS respectively in the treatment process. Experiments were done in triplicates and treated data is presented as graphs. A detailed analyses of this study can be found in the article "Degradation of theophylline in a UV254/PS system: matrix effect and application to a factory effluent" [1] published in Chemical Engineering Journal.
Specifications TableData related to treatment of a pharmaceutical effluent solution using a UV/PS system is presented.Researchers involved in advanced oxidation processes and treatment of pharmaceuticals in water can benefit from the following data.Presented data can be utilized to develop a continuous treatment system for pharmaceutical effluents by taking into consideration the effects of spiking the reactor with the oxidant or the pharmaceutical. Additionally, effect of phosphates and comparison between two different oxidants provide useful information in this process.The homemade reactor's setup can be utilized by other interested researchers in a study where similar commercially available UV lamps are used and system cooling is required.
Data
Calibration curve and some properties for TP and presented in Fig. 1.
Fig. 1
(a) Calibration curve of TP obtained using HPLC/DAD at wavelength of 270 nm, (b) LINEST output for TP calibration curve, and (c) selected TP characteristics [2].
(a) Calibration curve of TP obtained using HPLC/DAD at wavelength of 270 nm, (b) LINEST output for TP calibration curve, and (c) selected TP characteristics [2].The observed rate constants, obtained for pseudo-first order fitting, for degradation of TP at different [PS]0 is presented in Table 1.
Table 1
Degradation of [TP]0 = 10 mg L-1 at [PS]0 = 0.01–0.5 mM. kobs and linearity constant (R2) obtained for plots of versus time (min) for tested conditions upon first order fitting are presented.
[TP] ppm
[PS]0 mM
kobs x 10−1 (min−1)
R2
10
0.01
0.04 (±0.01)
0.9675
0.1
0.49 (±0.02)
0.9553
0.25
1.74 (±0.06)
0.9933
0.5
3.7 (±0.2)
0.955
Degradation of [TP]0 = 10 mg L-1 at [PS]0 = 0.01–0.5 mM. kobs and linearity constant (R2) obtained for plots of versus time (min) for tested conditions upon first order fitting are presented.A mini review of effects of chlorides and bicarbonates on the degradation of different organic probes in PS-based AOPs are presented in Table 2 and Table 3 respectively.
Table 2
Review of the effect of chloride (Cl−) presence on the degradation of several organic probes in Persulfate activated systems. (+) and (−) represent an increase or a decrease in the degradation rate constant of the oxidation reaction, respectively.
Family
Probe
Structure
PS system used
[PS]0 mM
[Cl−] (mM)
[NaCl] (mg L−1)
Effect on kobs
Main reactive radical species
Reference
Antibiotic
Florfenicol
Image 1
UV/PS
1
1, 10, 100
58.4, 584, 5844
–
No data
[3]
Sulfamethazine
Image 2
Heat/PS
2
5, 10
292, 584
Negligible effect
SO4•−
[4]
100, 200
5844, 11688
+
Penicillin G
Image 3
Heat/PS
0.5
0.171
10
–
SO4•−
[5]
0.0943
5.51
–
Antipyretic
Acetaminophen
Image 4
Fe2+/PS
0.8
0.1
5.84
Negligible effect
SO4•−
[6]
2
116.9
–
5, 10
292, 584
+
UV/PS
0.132
2, 10, 20
117, 584, 1169
+
SO4•−
[7]
50, 100
2922, 5844
–
Antipyrine
Image 5
Heat/PS
1.855
18.5
1081
+
SO4•−
[8]
1850
108114
–
Beta blocker
Atenolol
Image 6
Heat/PS
0.5
1, 5, 10, 50
58.4, 292, 584, 2922
Negligible effect
SO4•−
[9]
Bisoprolol
Image 7
Heat/PS
1
0.0855
5
+
SO4•−, OH•
[10]
Hormone
17β-estradiol
Image 8
UV/PS
Slow-release flow through system
0.028, 0.282, 2.82
1.6, 16.5, 165
–
SO4•−
[11]
28.2, 42.3
1648, 2472
+
56.4, 564, 846, 1269
3256, 32960, 49440, 74160
–
Nonsteroidal anti-inflammatory
Diclofenac
Image 9
UV/PS
1
25, 50
1461, 2922
+
No data
[12]
100, 200
5844, 11688
–
Ketoprofen
Image 10
Heat/PS
1
3.42
200
+
No data
[13]
34.2, 342
2000, 20000
–
UV/PS
0.1
3.42
200
+
34.2, 342
2000, 20000
–
Fe2+/PS
0.5
3.42, 34.2, 342
200, 2000, 20000
–
Persistent organic molecules Pesticides
Cyclohexanoic acid
Image 11
UV/PS
2
14.1
824
–
OH•
[14]
1,1,1-Trichloroethane
Image 12
Heat/PS
15
1
58.4
Negligible effect
No data
[15]
10, 100
584.4, 5844
–
Triclosan
Image 13
Heat/PS
0.155
0.15, 1, 10
8.8, 58.4, 584.4
–
SO4•−
[16]
20, 50
1169, 2922
+
Diatrizoate
Image 14
UV/PS
12
1, 10, 100
58.4, 584.4, 5844
Negligible effect
SO4•−
[17]
500
29220
–
Table 3
Review of the effect of bicarbonate (HCO3−) presence on the degradation of several organic probes in Persulfate activated systems. (+) and (−) represent an increase or a decrease in the degradation rate constant of the oxidation reaction, respectively.
Family
Probe
Structure
PS system used
[PS]0 mM
[HCO3−] (mM)
Effect on kobs
Main reactive radical species
Reference
Antibiotic
Florfenicol
Image 1
UV/PS
1
1, 10, 100
–
No data
[3]
Sulfamethazine
Image 2
Heat/PS
2
5, 10, 50
+
SO4•−
[4]
Penicillin G
Image 3
Heat/PS
0.5
0.0943
–
SO4•−
[5]
Antipyretic
Acetaminophen
Image 4
UV/PS
0.132
2
–
SO4•−
[7]
10, 20, 50, 100
+
Antipyrine
Image 15
Heat/PS
1.855
18.55, 92.75, 185.5, 927.5
–
SO4•−
[8]
Beta blocker
Atenolol
Image 6
Heat/PS
0.5
1, 5, 10, 50
–
SO4•−
[9]
Hormone
17β-estradiol
Image 8
UV/PS
Slow-release flow through system
4.76
+
SO4•−
[11]
11.9, 23.8
–
Nonsteroidal anti-inflammatory
Diclofenac
Image 9
UV/PS
1
25, 50, 100 and 200
+
No data
[12]
Ketoprofen
Image 10
Heat/PS
1
1, 50, 100 mM
–
No data
[13]
Persistent organic molecules Pesticide
1,1,1-Trichloroethane
Image 16
Heat/PS
15
1, 10, 100
–
No data
[15]
Triclosan
Image 13
Heat/PS
0.155
1–50
–
SO4•−
[16]
Diatrizoate
Image 14
UV/PS
12
2.5, 5, 10, 20, 40
+
SO4•−
[17]
Review of the effect of chloride (Cl−) presence on the degradation of several organic probes in Persulfate activated systems. (+) and (−) represent an increase or a decrease in the degradation rate constant of the oxidation reaction, respectively.Review of the effect of bicarbonate (HCO3−) presence on the degradation of several organic probes in Persulfate activated systems. (+) and (−) represent an increase or a decrease in the degradation rate constant of the oxidation reaction, respectively.TP degradation in UV/PS system in the presence of phosphates (Fig. 2) and chloroform (Fig. 4) is studied in a simulated pharmaceutical effluent with [TP]0 = 10 mg L−1 and [PS]0 = 0.25 mM. Comparison between UV and base activation of PS is studied with 10 mM phosphate buffer at pH = 11 used (Fig. 3). Additionally, H2O2 and PS oxidants are compared (Fig. 5).
Fig. 2
(a) Effect of phosphates (0, 10 and 20 mM) on TP degradation. (b) pH in buffered and non-buffered solutions. Experimental conditions: [TP]0 = 10 mg L−1, [PS]0 = 0.25 mM. Error bars are calculated as , where absent bars fall within the symbols.
Fig. 4
TP degradation in presence and absence of chloroform used as superoxide radical quencher. Solution is saturated with chloroform at 20 °C. Experimental conditions: [TP]0 = 10 mg L−1 and [PS]0 = 0.25 mM.
Fig. 3
Comparison between UV and base activation of PS. Experimental conditions: [TP]0 = 10 mg L−1, [PS]0 = 0.25 mM, and [phosphate buffer] = 10 mM of pH = 11 in both cases. Error bars are calculated as , where absent bars fall within the symbols.
Fig. 5
Comparison of oxidation effectivity of H2O2 and PS toward TP. (a) [TP]/[TP]0 for three different tested systems and (b) the corresponding pH at initial (t = 0 min) and final time (t = 16 min) with the calculated kobs. Experimental conditions: [TP]0 = 10 mg L−1, [PS]0 = 0.25 mM, [H2O2]0 = 0.25 mM and [PS]0 = [H2O2]0 = 0.125 mM for the case of mixed oxidants.
(a) Effect of phosphates (0, 10 and 20 mM) on TP degradation. (b) pH in buffered and non-buffered solutions. Experimental conditions: [TP]0 = 10 mg L−1, [PS]0 = 0.25 mM. Error bars are calculated as , where absent bars fall within the symbols.Comparison between UV and base activation of PS. Experimental conditions: [TP]0 = 10 mg L−1, [PS]0 = 0.25 mM, and [phosphate buffer] = 10 mM of pH = 11 in both cases. Error bars are calculated as , where absent bars fall within the symbols.TP degradation in presence and absence of chloroform used as superoxide radical quencher. Solution is saturated with chloroform at 20 °C. Experimental conditions: [TP]0 = 10 mg L−1 and [PS]0 = 0.25 mM.Comparison of oxidation effectivity of H2O2 and PS toward TP. (a) [TP]/[TP]0 for three different tested systems and (b) the corresponding pH at initial (t = 0 min) and final time (t = 16 min) with the calculated kobs. Experimental conditions: [TP]0 = 10 mg L−1, [PS]0 = 0.25 mM, [H2O2]0 = 0.25 mM and [PS]0 = [H2O2]0 = 0.125 mM for the case of mixed oxidants.A real effluent solution containing [TP]0 ≈ 160 mg L−1 is treated with simultaneous and successive additions of PS (Fig. 6a). The UV254/PS system was studied upon spiking the reactor with varying amounts of concentrated effluent solution (Fig. 6b).
Fig. 6
Degradation of TP in a real pharmaceutical effluent sample in UV254/PS system. (a) PS is added either successively over 5 cycles ([PS] = 5 mM/cycle) or simultaneously at t = 0 min ([PS] = 25 mM) to TP effluent solution ([TP]0 ≈ 160 mg L-1). (b) Concentrated effluent solution spiked over 3 cycles of 1 h each starting at [TP]0 ≈ 160 mg L-1 and [PS]0 = 25 mM added at t = 0 min. The insets correspond to the average % RSE calculated for every cycle. Error bars are calculated as , where absent bars fall within the symbols.
Degradation of TP in a real pharmaceutical effluent sample in UV254/PS system. (a) PS is added either successively over 5 cycles ([PS] = 5 mM/cycle) or simultaneously at t = 0 min ([PS] = 25 mM) to TP effluent solution ([TP]0 ≈ 160 mg L-1). (b) Concentrated effluent solution spiked over 3 cycles of 1 h each starting at [TP]0 ≈ 160 mg L-1 and [PS]0 = 25 mM added at t = 0 min. The insets correspond to the average % RSE calculated for every cycle. Error bars are calculated as , where absent bars fall within the symbols.The raw data corresponding to all figures and tables can be found in the file “raw data” within this article. These data include concentrations of TP and PS and the standard deviation for their measurement.
Experimental design, materials, and methods
Experimental setup: UV reactors
A bench-scale experimental setup was used simulating the commercial UV water sterilization apparatus. Six units of a generic 1 gallon per minute UV water disinfection element (Fig. 7a) were used in the construction of the experimental setup. The commercial units utilized originally consist of a UV 11-W low-pressure mercury lamp (LPHgL) (Philips TUV 11W G11 T5, Poland), fitted in a quartz tube placed in a 280 mL 316 stainless steel casing that continuously intakes pre-filtered water. The UV lamps and their quartz fittings were utilized from the commercial product, and the stainless-steel casing was replaced by a 400 mL home-made borosilicate cylinder. The borosilicate used in the setup is as inert as the stainless-steel used in the commercial product, however the borosilicate allows easy handling and real-time monitoring of reactors to assure no precipitates were formed. Our developed system (Fig. 7b) utilizes a temperature-controlled water bath (20 °C) by the aid of a PolyScience MM7 chiller. UV-254 nm intensity was 3.2 mWcm−2 ± 0.16 measured using a radiometer (Model UVC-254 Lutron; Taipei, Taiwan) at a distance of 3cm, which is similar to the distance between the lamp and the termination part of the solution treated in the designed system. All experiments were done in triplicates, where two different experiments could be done at once.
Fig. 7
(a) Generic 1 gallon per minute UV continuous water disinfection element, and (b) an exploded diagram of the experimental setup.
(a) Generic 1 gallon per minute UV continuous water disinfection element, and (b) an exploded diagram of the experimental setup.
Experimental procedure
Stock solution of TP (0.555 mM) was prepared by dissolving 100 mg of dry TP powder in one liter of DI water, and that of Persulfate (PS) (100 mM) was prepared by dissolving 2.38 g of sodium persulfate in 100 mL of DI water. Both solutions were stored in dark at 4 °C for a maximum period of two weeks. For persulfate detection method potassium iodide solution (40 mM) was prepared by dissolving 6.64 g of KI and 5 g of NaHCO3 in 1 L volumetric flask and left to stir overnight. Before every experiment LPHgLs (11 Watts) were stabilized for a period of 60 min. Monthly routine check of the LPHgL's UV-254 nm intensity was performed using a UVC radiometer (UVC-254 Lutron, Taiwan) to confirm that the power of the lamps is within ± 10% the original value, otherwise the lamps were replaced by new ones. The water chiller was turned on and set at 20 °C 60 minutes ahead of all experiments. Temperature of water in reaction medium was measured several times during the experiment to make sure it is within a range of 20 ± 2 °C. The order of addition of reagents was as follows: first Theophylline solution from stock was placed in the reactor, then DI was added, followed by additive matrix solutions (if any), finally, PS or H2O2, from stock solutions were added. Samples were withdrawn every 2 min using a separate syringe for each reactor and placed in 2 mL HPLC vials after filtration by a 0.45 μm PTFE 13 mm disc filters. Wastewater used in experiments was pre-filtered using a 1 μm ashless glass fiber filter. For the case of real pharmaceutical factory effluent, water samples were collected from washing the reactors used in the production process (Fig. 8).
Fig. 8
Wastewater samples containing TP collected from a local pharmaceutical production plant. (a) Washing of 1000 L 316 SS L mixing container, (b) collecting wastewater samples in amber bottles, and (c) filter press used in the manufacturing process.
Wastewater samples containing TP collected from a local pharmaceutical production plant. (a) Washing of 1000 L 316 SS L mixing container, (b) collecting wastewater samples in amber bottles, and (c) filter press used in the manufacturing process.
Specifications Table
Subject
Water Science and Technology
Specific subject area
water treatment, AOPs, UV254, persulfate
Type of data
TableFigure
How data were acquired
High performance liquid chromatography (HPLC, Agilent 1100 series)
Data format
Raw and Analyzed
Parameters for data collection
Experiments were done in triplicates in separate reactors. Room temperature was maintained throughout the reactions.
Description of data collection
HPLC coupled to DAD was used to track TP concentrations throughout the reaction. A modified-HPLC method utilizing KI was used to track PS concentrations. The average and error bars were obtained for each data point presented in the graph.
Data source location
American University of BeirutBeirutLebanon
Data accessibility
Within the article
Related research article
Author's nameSuha Al Hakim, Saly Jaber, Nagham Zein Eddine, Abbas Baalbaki, Antoine Ghauch** Corresponding Author: e mail antoine.ghauch@aub.edu.lb Phone: +961 1350 000 Fax: +961 1 365 217TitleDegradation of theophylline in a UV254/PS system: matrix effect and application to a factory effluent [1]JournalChemical Engineering JournalDOIhttps://doi.org/10.1016/j.cej.2019.122478
Value of the Data
Data related to treatment of a pharmaceutical effluent solution using a UV/PS system is presented.
Researchers involved in advanced oxidation processes and treatment of pharmaceuticals in water can benefit from the following data.
Presented data can be utilized to develop a continuous treatment system for pharmaceutical effluents by taking into consideration the effects of spiking the reactor with the oxidant or the pharmaceutical. Additionally, effect of phosphates and comparison between two different oxidants provide useful information in this process.
The homemade reactor's setup can be utilized by other interested researchers in a study where similar commercially available UV lamps are used and system cooling is required.