Literature DB >> 31650834

Structural Changes of Mercaptohexanol Self-Assembled Monolayers on Gold and Their Influence on Impedimetric Aptamer Sensors.

Xingxing Xu, Asta Makaraviciute, Shalen Kumar1,2, Chenyu Wen, Martin Sjödin, Eldar Abdurakhmanov3, U Helena Danielson3, Leif Nyholm4, Zhen Zhang.   

Abstract

Despite a large number of publications describing biosensors based on electrochemical impedance spectroscopy (EIS), little attention has been paid to the stability and reproducibility issues of the sensor interfaces. In this work, the stability and reproducibility of faradaic EIS analyses on the aptamer/mercaptohexanol (MCH) self-assembled monolayer (SAM)-functionalized gold surfaces in ferri- and ferrocyanide solution were systematically evaluated prior to and after the aptamer-probe DNA hybridization. It is shown that the EIS data exhibited significant drift, and this significantly affected the reproducibility of the EIS signal of the hybridization. As a result, no significant difference between the charge transfer resistance (RCT) changes induced by the aptamer-target DNA hybridization and that caused by the drift could be identified. A conditioning of the electrode in the measurement solution for more than 12 h was required to reach a stable RCT baseline prior to the aptamer-probe DNA hybridization. The monitored drift in RCT and double layer capacitance during the conditioning suggests that the MCH SAM on the gold surface reorganized to a thinner but more closely packed layer. We also observed that the hot binding buffer used in the following aptamer-probe DNA hybridization process could induce additional MCH and aptamer reorganization, and thus further drift in RCT. As a result, the RCT change caused by the aptamer-probe DNA hybridization was less than that caused by the hot binding buffer (blank control experiment). Therefore, it is suggested that the use of high temperature in the EIS measurement should be carefully evaluated or avoided. This work provides practical guidelines for the EIS measurements. Moreover, because SAM-functionalized gold electrodes are widely used in biosensors, for example, DNA sensors, an improved understanding of the origin of the observed drift is very important for the development of well-functioning and reproducible biosensors.

Entities:  

Year:  2019        PMID: 31650834     DOI: 10.1021/acs.analchem.9b03946

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

Review 1.  Immobilization Techniques for Aptamers on Gold Electrodes for the Electrochemical Detection of Proteins: A Review.

Authors:  Franziska V Oberhaus; Dieter Frense; Dieter Beckmann
Journal:  Biosensors (Basel)       Date:  2020-04-28

Review 2.  Recent Progress on Highly Selective and Sensitive Electrochemical Aptamer-based Sensors.

Authors:  Tianwei Tang; Yinghuan Liu; Ying Jiang
Journal:  Chem Res Chin Univ       Date:  2022-05-05       Impact factor: 2.726

Review 3.  Novel devices for isolation and detection of bacterial and mammalian extracellular vesicles.

Authors:  Shiana Malhotra; Zarinah M Amin; Garima Dobhal; Sophie Cottam; Thomas Nann; Renee V Goreham
Journal:  Mikrochim Acta       Date:  2021-03-26       Impact factor: 5.833

Review 4.  Electrochemical Aptasensors: Current Status and Future Perspectives.

Authors:  Ragaa Abd-Ellatief; Maha Ragaa Abd-Ellatief
Journal:  Diagnostics (Basel)       Date:  2021-01-11

5.  The challenge of long-term stability for nucleic acid-based electrochemical sensors.

Authors:  Alexander Shaver; Netzahualcóyotl Arroyo-Currás
Journal:  Curr Opin Electrochem       Date:  2021-12-01

6.  Role of Nanoscale Roughness and Polarity in Odd-Even Effect of Self-Assembled Monolayers.

Authors:  Chuanshen Du; Zhengjia Wang; Jiahao Chen; Andrew Martin; Dhruv Raturi; Martin Thuo
Journal:  Angew Chem Int Ed Engl       Date:  2022-06-01       Impact factor: 16.823

7.  Effects of Experimental Conditions on the Signaling Fidelity of Impedance-Based Nucleic Acid Sensors.

Authors:  Vasileia Vogiazi; Armah de la Cruz; William R Heineman; Ryan J White; Dionysios D Dionysiou
Journal:  Anal Chem       Date:  2021-01-04       Impact factor: 6.986

  7 in total