Literature DB >> 31648570

Intraoperative storage of saphenous vein grafts in coronary artery bypass grafting.

Catherine J Pachuk1, Sophie K Rushton-Smith1, Maximilian Y Emmert2,3.   

Abstract

Background: Saline is not biocompatible with saphenous vein grafts and does not protect against ischemia reperfusion injury. We compared normal heparinized saline with DuraGraft, a new graft-storage solution, in in-vitro and ex-vivo assays to evaluate the effects on cells and vascular graft tissue.
Methods: Human saphenous vein (HSV) segments and isolated pig mammary veins (PMVs) were flushed and submerged in heparinized DuraGraft or heparinized saline for prespecified times. Following exposure, HSV segments were evaluated for viability and tissue morphology, and PMVs underwent histological assessments, to evaluate vein morphology and effects on the vascular endothelium. The performance of saline versus DuraGraft was compared in an ISO-compliant biocompatibility assay for cytotoxicity.
Results: Loss of HSV graft-cell viability was observed as early as 15 minutes post-exposure to saline whereas viability was maintained up to 5 hours' exposure to DuraGraft. Histological analyses performed with PMVs demonstrated endothelial damage in PMVs stored in saline. Cytotoxicity assays demonstrated that saline-induced microscopically visible cell damage occurred within 60 minutes. DuraGraft-treated cells did not show evidence of damage or reactivity.Conclusions: Normal saline caused damage to vascular endothelium, loss of graft cell viability, and mediated cell damage; no evidence of damage or reactivity was observed in DuraGraft-exposed cells.

Entities:  

Keywords:  Coronary artery bypass graft; graft failure; saphenous vein grafts; vein graft disease

Mesh:

Substances:

Year:  2019        PMID: 31648570     DOI: 10.1080/17434440.2019.1682996

Source DB:  PubMed          Journal:  Expert Rev Med Devices        ISSN: 1743-4440            Impact factor:   3.166


  6 in total

1.  Effect of different storage solutions on oxidative stress in human saphenous vein grafts.

Authors:  Ilker Tekin; Meltem Demir; Sebahat Özdem
Journal:  J Cardiothorac Surg       Date:  2022-01-16       Impact factor: 1.637

2.  Efficacy of Intraoperative Vein Graft Storage Solutions in Preserving Endothelial Cell Integrity during Coronary Artery Bypass Surgery.

Authors:  Francesca Toto; Tiziano Torre; Lucia Turchetto; Viviana Lo Cicero; Sabrina Soncin; Catherine Klersy; Stefanos Demertzis; Enrico Ferrari
Journal:  J Clin Med       Date:  2022-02-18       Impact factor: 4.241

3.  Aspirin Reduces Ischemia-Reperfusion Injury Induced Endothelial Cell Damage of Arterial Grafts in a Rodent Model.

Authors:  Gábor Veres; Kálmán Benke; Roland Stengl; Yang Bai; Klára Aliz Stark; Alex Ali Sayour; Tamás Radovits; Sivakkanan Loganathan; Sevil Korkmaz-Icöz; Matthias Karck; Gábor Szabó
Journal:  Antioxidants (Basel)       Date:  2022-01-18

4.  Graft preservation confers myocardial protection during coronary artery bypass grafting.

Authors:  Philipp Szalkiewicz; Maximilian Y Emmert; Paul P Heinisch; Zsuzsanna Arnold; Ingo Crailsheim; Markus Mach; Thomas Aschacher; Martin Grabenwöger; Bernhard Winkler
Journal:  Front Cardiovasc Med       Date:  2022-07-28

5.  Current intraoperative storage and handling practices of autologous bypass conduit: A survey of the royal australasian college of surgeons.

Authors:  A B Haymet; N Pinto; S Peden; T Cohen; M P Vallely; D McGiffin; R Naidoo; J Jenkins; J Y Suen; J F Fraser
Journal:  Front Surg       Date:  2022-08-26

6.  Preservation solutions to improve graft patency: The devil is in the detail.

Authors:  Etem Caliskan; Catherine J Pachuk; Louis P Perrault; Maximilian Y Emmert
Journal:  J Cardiothorac Surg       Date:  2020-08-27       Impact factor: 1.637

  6 in total