Literature DB >> 31639827

Three-Dimensional Neurite Characterization of Small Incision Lenticule Extraction Derived Lenticules.

Francisco Bandeira1,2,3, Gary Hin-Fai Yam1,4,5, Yu-Chi Liu1,4,6, Kavya Devarajan1, Jodhbir S Mehta1,4,6,7,8.   

Abstract

Purpose: We study the density and excitatory response of neurites, and Schwann cells (SCs) in fresh and cryopreserved stromal lenticules derived from small incision lenticule extraction (SMILE).
Methods: Human stromal lenticules (n = 23) were immunostained for β III-tubulin and imaged using spinning disk confocal laser microscopy, followed by three-dimensional reconstruction, to reveal neurite distribution. The lenticule neurite density (LND) was assessed using a validated neurite tracing and length measurement method with NeuronJ. LND was compared among groups of different lenticule thickness (71-165 μm) obtained from -3 to >-6 diopters (D) corrections. SCs were identified by marker expression and the laser effect on SC-neurite interaction was examined under transmission electron microscopy (TEM). Fresh porcine SMILE-lenticules (n = 18) were used for LND comparison among storage conditions and functional excitatory calcium response assay.
Results: Using a validated neurite length measurement method, we found an inverse correlation of LND with lenticule thickness. Higher LND was found in thinner lenticules obtained from lower power of correction (r = -0.8925, P < 0.0001), whereas total lenticule neurite lengths did not alter significantly with regards to lenticule thickness. SCs were identified by GAP43 and p75NTR expression and were closely associated with lenticule neurites under TEM. In porcine lenticules, LND and excitatory calcium response were reduced after cold and cryogenic storage, when compared to fresh lenticules. Conclusions: The stromal neurites showed variations in density related to SMILE lenticule thickness and cryopreservation. With the presence of SC support and excitatory response, these neurite residues could retain minimal functionality that might serve as a potential advantage in the event of lenticule implantation.

Entities:  

Year:  2019        PMID: 31639827     DOI: 10.1167/iovs.19-27566

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  3 in total

Review 1.  Preservation of corneal stromal lenticule: review.

Authors:  Martina Nemcokova; Jakub Dite; Yun Min Klimesova; Magdalena Netukova; Pavel Studeny
Journal:  Cell Tissue Bank       Date:  2022-02-06       Impact factor: 1.522

2.  Effect of corneal stromal lenticule customization on neurite distribution and excitatory property.

Authors:  Gary Hin-Fai Yam; Francisco Bandeira; Yu-Chi Liu; Kavya Devarajan; Nur Zahirah Binte M Yusoff; Hla-Myint Htoon; Jodhbir S Mehta
Journal:  J Adv Res       Date:  2021-09-16       Impact factor: 12.822

Review 3.  Human SMILE-Derived Stromal Lenticule Scaffold for Regenerative Therapy: Review and Perspectives.

Authors:  Mithun Santra; Yu-Chi Liu; Vishal Jhanji; Gary Hin-Fai Yam
Journal:  Int J Mol Sci       Date:  2022-07-19       Impact factor: 6.208

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.