Literature DB >> 31633574

Low-Radiation-Dose Stress Myocardial Perfusion Measurement Using First-Pass Analysis Dynamic Computed Tomography: A Preliminary Investigation in a Swine Model.

Logan Hubbard1, Shant Malkasian, Yixiao Zhao, Pablo Abbona, Jungnam Kwon, Sabee Molloi.   

Abstract

OBJECTIVES: The aim of this study was to assess the feasibility of a prospective first-pass analysis (FPA) dynamic computed tomography (CT) perfusion technique for accurate low-radiation-dose global stress perfusion measurement.
MATERIALS AND METHODS: The prospective FPA technique was evaluated in 10 swine (42 ± 12 kg) by direct comparison to a previously validated retrospective FPA technique. Of the 10 swine, 3 had intermediate stenoses with fractional flow reserve severities of 0.70 to 0.90. In each swine, contrast and saline were injected peripherally followed by dynamic volume scanning with a 320-slice CT scanner. Specifically, for the reference standard retrospective FPA technique, volume scans were acquired continuously at 100 kVp and 200 mA over 15 to 20 seconds, followed by systematic selection of only 2 volume scans for global perfusion measurement. For the prospective FPA technique, only 2 volume scans were acquired at 100 kVp and 50 mA for global perfusion measurement. All prospective global stress perfusion measurements were then compared with the corresponding reference standard retrospective global stress perfusion measurements through regression analysis. The CTDIvol and size-specific dose estimate of the prospective FPA technique were also determined.
RESULTS: All prospective global stress perfusion measurements (PPRO) at 50 mA were in good agreement with the reference standard retrospective global stress perfusion measurements (PREF) at 200 mA (PPRO = 1.07 PREF -0.09, r = 0.94; root-mean-square error = 0.30 mL/min per gram). The CTDIvol and size-specific dose estimate of the prospective FPA technique were 2.3 and 3.7 mGy, respectively.
CONCLUSIONS: Accurate low-radiation-dose global stress perfusion measurement is feasible using a prospective FPA dynamic CT perfusion technique.

Entities:  

Mesh:

Year:  2019        PMID: 31633574      PMCID: PMC6832844          DOI: 10.1097/RLI.0000000000000613

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  35 in total

1.  Mean transit time for videodensitometric assessment of myocardial perfusion and the concept of maximal flow ratio: a validation study in the intact dog and a pilot study in man.

Authors:  N H Pijls; G J Uijen; A Hoevelaken; T Pijnenburg; K L van Leeuwen; J H Fast; H S Bos; W R Aengevaeren; T van der Werf
Journal:  Int J Card Imaging       Date:  1990

Review 2.  Quantitative myocardial blood flow with Rubidium-82 PET: a clinical perspective.

Authors:  Christoffer E Hagemann; Adam A Ghotbi; Andreas Kjær; Philip Hasbak
Journal:  Am J Nucl Med Mol Imaging       Date:  2015-10-12

3.  Underestimation of myocardial blood flow by dynamic perfusion CT: Explanations by two-compartment model analysis and limited temporal sampling of dynamic CT.

Authors:  Masaki Ishida; Kakuya Kitagawa; Takashi Ichihara; Takahiro Natsume; Ryohei Nakayama; Naoki Nagasawa; Makiko Kubooka; Tatsuro Ito; Mio Uno; Yoshitaka Goto; Motonori Nagata; Hajime Sakuma
Journal:  J Cardiovasc Comput Tomogr       Date:  2016-01-13

4.  Cardiac magnetic resonance perfusion imaging for the functional assessment of coronary artery disease: a comparison with coronary angiography and fractional flow reserve.

Authors:  Johannes Rieber; Armin Huber; Isabelle Erhard; Silvia Mueller; Michael Schweyer; Andreas Koenig; Thomas M Schiele; Karl Theisen; Uwe Siebert; Stefan O Schoenberg; Maximilian Reiser; Volker Klauss
Journal:  Eur Heart J       Date:  2006-05-23       Impact factor: 29.983

5.  Impaired myocardial flow reserve on rubidium-82 positron emission tomography imaging predicts adverse outcomes in patients assessed for myocardial ischemia.

Authors:  Maria C Ziadi; Robert A Dekemp; Kathryn A Williams; Ann Guo; Benjamin J W Chow; Jennifer M Renaud; Terrence D Ruddy; Niroshi Sarveswaran; Rebecca E Tee; Rob S B Beanlands
Journal:  J Am Coll Cardiol       Date:  2011-08-09       Impact factor: 24.094

6.  A new method for cardiac computed tomography regional function assessment: stretch quantifier for endocardial engraved zones (SQUEEZ).

Authors:  Amir Pourmorteza; Karl H Schuleri; Daniel A Herzka; Albert C Lardo; Elliot R McVeigh
Journal:  Circ Cardiovasc Imaging       Date:  2012-02-16       Impact factor: 7.792

7.  Prognostic Value of Combined CT Angiography and Myocardial Perfusion Imaging versus Invasive Coronary Angiography and Nuclear Stress Perfusion Imaging in the Prediction of Major Adverse Cardiovascular Events: The CORE320 Multicenter Study.

Authors:  Marcus Y Chen; Carlos E Rochitte; Armin Arbab-Zadeh; Marc Dewey; Richard T George; Julie M Miller; Hiroyuki Niinuma; Kunihiro Yoshioka; Kakuya Kitagawa; Hajime Sakuma; Roger Laham; Andrea L Vavere; Rodrigo J Cerci; Vishal C Mehra; Cesar Nomura; Klaus F Kofoed; Masahiro Jinzaki; Sachio Kuribayashi; Arthur J Scholte; Michael Laule; Swee Yaw Tan; John Hoe; Narinder Paul; Frank J Rybicki; Jeffrey A Brinker; Andrew E Arai; Matthew B Matheson; Christopher Cox; Melvin E Clouse; Marcelo F Di Carli; João A C Lima
Journal:  Radiology       Date:  2017-03-14       Impact factor: 11.105

Review 8.  Advantages and disadvantages of PET and SPECT in a busy clinical practice.

Authors:  Timothy M Bateman
Journal:  J Nucl Cardiol       Date:  2012-02       Impact factor: 5.952

9.  Comparison of positron emission tomography measurement of adenosine-stimulated absolute myocardial blood flow versus relative myocardial tracer content for physiological assessment of coronary artery stenosis severity and location.

Authors:  Mohammad M Hajjiri; Marcia B Leavitt; Hui Zheng; Amy E Spooner; Alan J Fischman; Henry Gewirtz
Journal:  JACC Cardiovasc Imaging       Date:  2009-06

10.  Dynamic CT perfusion measurement in a cardiac phantom.

Authors:  Benjamin P Ziemer; Logan Hubbard; Jerry Lipinski; Sabee Molloi
Journal:  Int J Cardiovasc Imaging       Date:  2015-07-09       Impact factor: 2.357

View more
  4 in total

Review 1.  Metabolic flux between organs measured by arteriovenous metabolite gradients.

Authors:  Hosung Bae; Katie Lam; Cholsoon Jang
Journal:  Exp Mol Med       Date:  2022-09-08       Impact factor: 12.153

2.  Absolute cerebral blood flow: Assessment with a novel low-radiation-dose dynamic CT perfusion technique in a swine model.

Authors:  Pablo Abbona; Yixiao Zhao; Logan Hubbard; Shant Malkasian; Brooklynn Flynn; Sabee Molloi
Journal:  J Neuroradiol       Date:  2021-10-09       Impact factor: 4.600

3.  Combining perfusion and angiography with a low-dose cardiac CT technique: a preliminary investigation in a swine model.

Authors:  Logan Hubbard; Shant Malkasian; Yixiao Zhao; Pablo Abbona; Sabee Molloi
Journal:  Int J Cardiovasc Imaging       Date:  2021-01-27       Impact factor: 2.357

4.  Dynamic CT myocardial perfusion without image registration.

Authors:  Logan Hubbard; Shant Malkasian; Sabee Molloi
Journal:  Sci Rep       Date:  2022-07-23       Impact factor: 4.996

  4 in total