Literature DB >> 31627154

Utilization of Cu-nanoparticles as medication agent to reduce atherosclerotic lesions of a bifurcated artery having compliant walls.

Iqra Shahzadi1, Sana Suleman2, S Saleem3, S Nadeem2.   

Abstract

OBJECTIVE: A theoretical analysis is presented to study the bio-nanofluid with copper as medication agent for atherosclerotic bifurcated artery with flexible walls. DESIGN/APPROACH: The circulatory framework in human body is comprised of a system of veins that incorporate the bifurcation in this way the impact of copper nanoparticles on parent, at apex and on daughter artery regions (in the wake of being bifurcated) is watched. Streaming of blood along vessel segment is recognized to be newtonian. The consistent idea of the atherosclerotic arterial wall is additionally considered to make relationship with permeability aspects with arterial wall thickness. Copper nanoparticles are utilized to reduce the atherosclertic lesions for bifurcated stenotic artery.
FINDINGS: The designed equations along with the experimental values of copper nanoparticles and blood are utilized for theoretical investigation. Moreover, hemodynamics impacts are also figure out to examine the flow of blood for atherosclertic artery. Comparison between parent and daughter artery is plotted through velocity profile. To see the theoretical assistance of this copper mediated model in biomedical field, graphical illustration is presented. At the end, noticed that the inclusion of copper nanoparticles enhances the velocity significantly both for parent as well as daughter artery.
CONCLUSIONS: The circulation of blood is considered to be different from pressure between portions of atherosclerotic and non-atherosclerotic artery. Shear stress is reduces by changing the bifurcation angle for daughter artery while trend is reversed for parent artery. The size of inner circularting bolus decreases by changing compliant parameter for parent artery while shape is changed for daughter artery.
Copyright © 2019. Published by Elsevier B.V.

Entities:  

Keywords:  Bifurcated artery; Blood flow; Compliant walls; Cu- nanoparticles; Mild stenosis

Mesh:

Substances:

Year:  2019        PMID: 31627154     DOI: 10.1016/j.cmpb.2019.105123

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  1 in total

1.  Concentric ballooned catheterization to the fractional non-newtonian hybrid nano blood flow through a stenosed aneurysmal artery with heat transfer.

Authors:  Obaid Ullah Mehmood; Sehrish Bibi; Dzuliana F Jamil; Salah Uddin; Rozaini Roslan; Mohd Kamalrulzaman Md Akhir
Journal:  Sci Rep       Date:  2021-10-14       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.