Literature DB >> 31624997

Warming efficacy of Ranger™ and FT2800 fluid warmer under different room temperatures and flow rates.

Ximou Xu1, Chaohui Lian1, Yao Liu1,2, Hehe Ding1, Yi Lu1, Wangning ShangGuan3.   

Abstract

The comparison of the heating capabilities with different warming system between 3M™ Ranger™ warmer (3M) and FT2800 fluid warmer (FT) under different room temperatures and infusion rates, has been rarely reported previously. The study was then aimed to compare the warming efficacies of dry heat technology (3M) and coaxial warming system (FT) under different room temperatures and infusion rates, the advantages and disadvantages of both infusion systems would be compared to provide reference for clinical infusion practice. In the study, both target warming temperatures of 3M and FT warmer were set at 41 °C, fluid was administrated under 20, 22 and 24 °C room temperatures and drip rates of 60, 80, 100, 120, 140, 160, 200, 350 drops min-1. The fluid temperature at the outlet of the infusion tube (Toutlet) was measured and compared. The Toutlet of FT was higher than that of 3 M (P < 0.001) under different room temperatures. The Toutlet of FT increased with the room temperature raised (P < 0.05). As for 3M, Toutlet was lowest at 20 °C (P < 0.001) and no statistical difference of Toutlet was found between 22 and 24 °C (P = 0.667). Linear regression showed that the Toutlet of 3M increased with the speed up of drip rate, while the Toutlet of FT was decreased. The relationship between Toutlet & room temperature & drip rate for both 3M and FT warmers was calculated by a formula. 3M Ranger™ and FT2800 show different heating capabilities under different room temperatures and drip rates. 3M is more efficient at high flow rate while FT is more efficient at low flow rate. There is a formula relationship between Toutlet & room temperature & drip rate for both 3M and FT warmers.

Entities:  

Keywords:  Fluid warming system; Heating capability; Hypothermia; Infusion rate; Room temperature

Year:  2019        PMID: 31624997     DOI: 10.1007/s10877-019-00400-1

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  2 in total

1.  What are the most important risk factors for a patient's developing intraoperative hypothermia?

Authors:  Alex Macario; Franklin Dexter
Journal:  Anesth Analg       Date:  2002-01       Impact factor: 5.108

2.  The effect of pre-warmed intravenous fluids on prevention of intraoperative hypothermia in cesarean section.

Authors:  Khodayar Oshvandi; Fatemeh Hasan Shiri; Mohammad Reza Fazel; Mahmoud Safari; Ali Ravari
Journal:  Iran J Nurs Midwifery Res       Date:  2014-01
  2 in total
  2 in total

1.  Impact of parylene coating on heating performance of intravenous fluid warmer: a bench study.

Authors:  Danielle K Bayoro; Herman Groepenhoff; Daniel Hoolihan; Edward A Rose; Michael J Pedro; Andreas D Waldmann
Journal:  BMC Anesthesiol       Date:  2022-02-10       Impact factor: 2.217

2.  Influence of flow rate, fluid temperature, and extension line on Hotline and S-line heating capability: an in vitro study.

Authors:  Hosu Kim; Tae Kyong Kim; Sukha Yoo; Jin-Tae Kim
Journal:  BMC Anesthesiol       Date:  2021-01-04       Impact factor: 2.217

  2 in total