Literature DB >> 31624987

Scanning electron microscopy study of different one-piece foldable acrylic intraocular lenses after injection through microincisional cataract surgery cartridges.

Paolo Cecchini1, Rossella D'Aloisio2, Chiara De Giacinto1, Gianluca Turco3, Daniele Tognetto1.   

Abstract

PURPOSE: To evaluate possible surface alterations of different models of one-piece foldable acrylic intraocular lenses (IOLs) after folding and ejecting process through 2.2-mm microincisional cataract surgery (MICS) cartridges.
METHODS: In this experimental laboratory study, the following IOLs were studied: Johnson&Johnson PCB00, HOYA iSert 251, Alcon AcrySof IQ SN60WF, Bausch&Lomb enVISTA MX-60. A total of 80 IOLs were analyzed. Twenty intraocular lenses of each type were studied: ten with a power of + 21 D ± 1 and ten with a power of + 28 D ± 1. IOLs were injected through a dedicated 2.2-mm MICS cartridge into a 50-mL vial containing 10 mL of deionized water. After rinsing and metallization process, scanning electron microscopy images were acquired.
RESULTS: All IOLs presented high-quality construction biomaterials. Some IOLs showed superficial scratches and tears on the optic surface, mainly positioned according to the direction of the stress induced by the folding process. In other cases, small superficial tears were seen in a more peripheral position.
CONCLUSIONS: All lenses showed excellent surface quality. After folding and injection process some superficial scratches and tears of the IOL optic were detected in some models. Further studies are needed to assess the possible effects of those superficial damages on the optical quality of the IOLs.

Entities:  

Keywords:  Foldable acrylic intraocular lenses; Microincisional cataract surgery; Optical quality; Scanning electron microscopy

Mesh:

Substances:

Year:  2019        PMID: 31624987     DOI: 10.1007/s10792-019-01193-7

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  18 in total

1.  Hydrophilic acrylic intraocular lenses.

Authors:  N Mamalis
Journal:  J Cataract Refract Surg       Date:  2001-09       Impact factor: 3.351

2.  Surface abnormalities on hydrophilic acrylic intraocular lenses implanted by an injector.

Authors:  C W Faschinger
Journal:  J Cataract Refract Surg       Date:  2001-06       Impact factor: 3.351

3.  Cataract surgery is refractive surgery.

Authors:  Emanuel Rosen
Journal:  J Cataract Refract Surg       Date:  2012-02       Impact factor: 3.351

Review 4.  Interventions for preventing posterior capsule opacification.

Authors:  Oliver Findl; Wolf Buehl; Peter Bauer; Thomas Sycha
Journal:  Cochrane Database Syst Rev       Date:  2010-02-17

5.  [Intraocular lenses for microincisional cataract surgery].

Authors:  T Kohnen; O K Klaproth
Journal:  Ophthalmologe       Date:  2010-02       Impact factor: 1.059

6.  [Influence of 3.0 mm incision coaxial phacoemulsification and microincision cataract surgery (MICS) on corneal thickness].

Authors:  Edward Wylegała; Małgorzata Rebkowska-Juraszek; Dariusz Dobrowolski; Anna Woyna-Orlewicz
Journal:  Klin Oczna       Date:  2009

7.  Structural analysis of cataract incision construction.

Authors:  P S Koch
Journal:  J Cataract Refract Surg       Date:  1991       Impact factor: 3.351

8.  Randomized intraindividual comparison of posterior capsule opacification between a microincision intraocular lens and a conventional intraocular lens.

Authors:  Georgia Cleary; David J Spalton; Joanne Hancox; James Boyce; John Marshall
Journal:  J Cataract Refract Surg       Date:  2009-02       Impact factor: 3.351

Review 9.  Comparison of efficacy between coaxial microincision and standard-incision phacoemulsification in patients with age-related cataracts: a meta-analysis.

Authors:  Lijun Wang; Xiao Xiao; Lin Zhao; Yi Zhang; Jianming Wang; Aiyi Zhou; Jianchao Wang; Qian Wu
Journal:  BMC Ophthalmol       Date:  2017-12-29       Impact factor: 2.209

10.  Comparison of surgically induced astigmatisms after clear corneal incisions of different sizes.

Authors:  Sung Chur Moon; Tarek Mohamed; I Howard Fine
Journal:  Korean J Ophthalmol       Date:  2007-03
View more
  1 in total

1.  Intensity simulation of photic effects after cataract surgery for off-axis light sources.

Authors:  Pooria Omidi; Alan Cayless; Achim Langenbucher
Journal:  PLoS One       Date:  2022-08-05       Impact factor: 3.752

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.