Literature DB >> 31623521

Inertial measurement unit-based hip flexion test as an indicator of sprint performance.

Ryu Nagahara1, Mai Kameda1, Jonathon Neville2,3, Jean-Benoit Morin2,4.   

Abstract

This study aimed 1) to examine the validity of inertial measurement unit (IMU)-based hip flexion strength test, and 2) to investigate the hip flexion strength test as an indicator of sprint performance. Eight males performed five repeated hip flexion-extension, while leg motion was recorded using an IMU and a motion capture system (Mocap). As the second experiment, 24 male athletes performed the IMU-based hip flexion strength test and sprinted 50 m, during which step-to-step ground reaction force (GRF) was recorded. The strength test variables were calculated using IMU and Mocap data including angular impulse, mean moment, and positive and negative work and power. Using GRF data, step-to-step spatiotemporal variables were obtained. The results showed high intra-class correlation coefficient and correlation coefficient (both >0.909) between IMU and Mocap for angular impulse, mean moment, positive work and power. The hip flexion mean moment showed significant correlation with running speed from the 5th-8th step section onwards. The angular impulse, mean moment, positive work and power are recommended to be used for the IMU-based hip flexion strength test variables in terms of accuracy and validity. Moreover, the proposed IMU-based hip flexion strength test can be an indicator for better sprinting performance.

Entities:  

Keywords:  IMU; Joint torque; accelerometer; fitness test; gyroscope; running

Mesh:

Year:  2019        PMID: 31623521     DOI: 10.1080/02640414.2019.1680081

Source DB:  PubMed          Journal:  J Sports Sci        ISSN: 0264-0414            Impact factor:   3.337


  7 in total

1.  Wearables for Running Gait Analysis: A Systematic Review.

Authors:  Rachel Mason; Liam T Pearson; Gillian Barry; Fraser Young; Oisin Lennon; Alan Godfrey; Samuel Stuart
Journal:  Sports Med       Date:  2022-10-15       Impact factor: 11.928

2.  A Survey to Assess the Quality of the Data Obtained by Radio-Frequency Technologies and Microelectromechanical Systems to Measure External Workload and Collective Behavior Variables in Team Sports.

Authors:  Markel Rico-González; Asier Los Arcos; Daniel Rojas-Valverde; Filipe M Clemente; José Pino-Ortega
Journal:  Sensors (Basel)       Date:  2020-04-16       Impact factor: 3.576

3.  Using Magneto-Inertial Measurement Units to Pervasively Measure Hip Joint Motion during Sports.

Authors:  Rachel E Horenstein; Yohann R Goudeau; Cara L Lewis; Sandra J Shefelbine
Journal:  Sensors (Basel)       Date:  2020-09-02       Impact factor: 3.576

4.  Inertial Measurement Unit Based Hip Flexion Strength-Power Test for Sprinters.

Authors:  Ryu Nagahara; Munenori Murata
Journal:  Front Sports Act Living       Date:  2020-10-30

5.  Hip Torque Is a Mechanistic Link Between Sprint Acceleration and Maximum Velocity Performance: A Theoretical Perspective.

Authors:  Kenneth P Clark; Laurence J Ryan
Journal:  Front Sports Act Living       Date:  2022-07-12

6.  Examination of a foot mounted IMU-based methodology for a running gait assessment.

Authors:  Fraser Young; Rachel Mason; Conor Wall; Rosie Morris; Samuel Stuart; Alan Godfrey
Journal:  Front Sports Act Living       Date:  2022-09-06

7.  'Whip from the hip': thigh angular motion, ground contact mechanics, and running speed.

Authors:  Kenneth P Clark; Christopher R Meng; David J Stearne
Journal:  Biol Open       Date:  2020-10-21       Impact factor: 2.422

  7 in total