Comparison of 3D echocardiographic-derived indices using fully automatic left ventricular endocardial tracing (heart model) and semiautomatic tracing (3DQ-ADV).

Nicholas D'Elia1,2, Vinesh Appadurai1,3, Michael Mallouhi1, Jun Ng1, Thomas Marwick2, Sudhir Wahi1,3.   

Abstract

AIMS: The availability of a true 3D dataset provides an opportunity for automation of left ventricular (LV) and left atrial (LA) measurements. Although manual and automated measurements of 3D volumes are known to correlate, the variance is an important parameter for the individual patient. The reasons for discrepancies remain unexplained. We hence aim to explain the disagreement between automated and manual LV and LA volumes. METHODS AND
RESULTS: A total of 355 patients underwent standard clinical echo, with offline analysis in both fully- (Heart Model, Philips) and semiautomated (3DQ-Adv, Philips) assessment of routine indices of LV and LA function and shape. Each image was classified according to quality using a 4-point scale as well as the American Society for Echocardiography guidelines for appropriate use of contrast. Bland-Altman plots were used to assess agreement, and t tests were used to assess differences in agreement. Predictors of volume discrepancy were sought with linear regression. Measures of LV and LA volumes were greater with automatic than semiautomatic assessment. The difference in left ventricular end-diastolic volume was dependent on the number of regional wall-motion abnormalities (RWMA) (β = 0.59, P < .04) and image quality (β = 19.71, P = .02). RWMA predicted the difference in left ventricular end-systolic volume (β = 0.83, P < .01) and left atrial end-systolic volume (β = -1.01 P < .01).
CONCLUSION: LV and LA volumes were higher with automatic than semiautomatic assessment. Image quality and RWMA may contribute to this discrepancy. These limitations need to be addressed before fully automatic assessment of 3D echocardiograms can be used in the clinic.
© 2019 Wiley Periodicals, Inc.

Entities:  

Keywords:  3D Echocardiography; LV endocardial border delineation; left ventricular volumes

Year:  2019        PMID: 31621957     DOI: 10.1111/echo.14502

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  1 in total

1.  Heart Model A.I. Three-Dimensional Echocardiographic Evaluation of Left Ventricular Function and Parameter Setting.

Authors:  Yuan-Yuan Xing; Hong-Yuan Xue; Yu-Quan Ye
Journal:  Int J Gen Med       Date:  2021-11-09
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.