Instantaneous aortic blood flow measurement with range-gated Doppler flowmeter in anesthetized rat.

J Benessiano, B I Levy, J B Michel.   

Abstract

The availability of a range-gated Doppler flowmeter system enabled us to construct miniaturized probes using piezoelectric crystals that emit an 8 MHz signal and receive the reflected sound waves from passing blood cells. The finished flow probe are 4 mm long and 3 mm in external diameter with lumen diameter appropriate to be placed around the ascending aorta in the rat. The accuracy of the Doppler method in measuring cardiac output in the rat was established by the demonstration of a significant correlation between cardiac output simultaneously measured from ultrasonic (Qd) and thermodilution (Qt) procedures in anesthetized Wistar rats (Qd = 0.55, Qt - 6.67 cm3/min, r = 0.69, p less than 0.001). An average Qd determination is 52.5% +/- 16% of average Qt. From aortic blood pressure and phasic aortic blood velocity, we have compared hemodynamic and cardiovascular functions in 15 spontaneously hypertensive rats and in 15 control Wistar-Kyoto rats under pentobarbital sodium anesthesia. The present study demonstrates that phasic aortic blood flow can be quantified easily and accurately in anesthetized rats by using a range-gated Doppler flowmeter and an implantable perivascular flow probe, and should provide a relatively simply method for investigating hemodynamic characteristics in models of disease such as ventricular hypertrophy and hypertension.

Entities:  

Mesh:

Year:  1985        PMID: 3162065     DOI: 10.1016/0160-5402(85)90047-6

Source DB:  PubMed          Journal:  J Pharmacol Methods        ISSN: 0160-5402


  6 in total

1.  Breakers of advanced glycation end products restore large artery properties in experimental diabetes.

Authors:  B H Wolffenbuttel; C M Boulanger; F R Crijns; M S Huijberts; P Poitevin; G N Swennen; S Vasan; J J Egan; P Ulrich; A Cerami; B I Lévy
Journal:  Proc Natl Acad Sci U S A       Date:  1998-04-14       Impact factor: 11.205

2.  Aminoguanidine prevents age-related arterial stiffening and cardiac hypertrophy.

Authors:  B Corman; M Duriez; P Poitevin; D Heudes; P Bruneval; A Tedgui; B I Levy
Journal:  Proc Natl Acad Sci U S A       Date:  1998-02-03       Impact factor: 11.205

3.  Chronic blockade of AT2-subtype receptors prevents the effect of angiotensin II on the rat vascular structure.

Authors:  B I Levy; J Benessiano; D Henrion; L Caputo; C Heymes; M Duriez; P Poitevin; J L Samuel
Journal:  J Clin Invest       Date:  1996-07-15       Impact factor: 14.808

4.  Polymeric perfluorocarbon nanoemulsions are ultrasound-activated wireless drug infusion catheters.

Authors:  Q Zhong; B C Yoon; M Aryal; J B Wang; T Ilovitsh; M A Baikoghli; N Hosseini-Nassab; A Karthik; R H Cheng; K W Ferrara; R D Airan
Journal:  Biomaterials       Date:  2019-03-20       Impact factor: 12.479

5.  Aminoguanidine treatment increases elasticity and decreases fluid filtration of large arteries from diabetic rats.

Authors:  M S Huijberts; B H Wolffenbuttel; H A Boudier; F R Crijns; A C Kruseman; P Poitevin; B I Lévy
Journal:  J Clin Invest       Date:  1993-09       Impact factor: 14.808

6.  Monitoring of Cardiorespiratory Parameters in Rats-Validation Based on Pharmacological Stimulation.

Authors:  Joanna Miklosz; Bartlomiej Kalaska; Stanislaw Zajaczkowski; Dariusz Pawlak; Andrzej Mogielnicki
Journal:  Pharmaceuticals (Basel)       Date:  2021-11-25
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.