Evelim Leal de Freitas Dantas Gomes1, Camilla Malta Dos Santos1, Anelise da Costa Souza Santos2, Aline Gomes da Silva1, Mariza Aparecida Malaquias França1, Dyele Souza Romanini1, Manoela Cristina Veiga de Mattos1, Andrea Fernanda Leal2, Dirceu Costa1.
Abstract
OBJECTIVE: Evaluate the physiological and autonomic nervous system responses of premature newborns to body position and noise in the neonatal intensive care unit.Entities:
Mesh:
Year: 2019 PMID: 31618347 PMCID: PMC7005950 DOI: 10.5935/0103-507X.20190054
Source DB: PubMed Journal: Rev Bras Ter Intensiva ISSN: 0103-507X
Figure 1Manual restraint.
Characteristics of the study sample
| Variables | N (%) | Minimum | Maximum | Mean | Standard deviation |
|---|---|---|---|---|---|
| Sex | |||||
| Male | 26 (52) | ||||
| Female | 24 (48) | ||||
| Gradational age (weeks) | 30 | 36 | 32.6 | 2.3 | |
| 30 | 11 (22) | ||||
| 31 | 2 (4) | ||||
| 32 | 7 (14) | ||||
| 33 | 7 (14) | ||||
| 34 | 11 (22) | ||||
| 35 | 10 (20) | ||||
| 36 | 2 (4) | ||||
| Chronological age (days) | 3 | 28 | 9.23 | 9.5 | |
| APGAR (1 minute) | 5 | 9 | 6.65 | 2.26 | |
| APGAR (5 minutes) | 5 | 10 | 8.42 | 1.3 | |
| Birth body weight (g) | 1,100 | 2,500 | 1,816.3 | 493.7 | |
| Study body weight (g) | 1,260 | 3,300 | 2,123.4 | 671.5 | |
| Type of birth | |||||
| Cesarean | 28 (56) | ||||
| Natural | 22 (44) |
Heart rate variability in the three positions
| Variables | Supine | Restraint | Prone |
|---|---|---|---|
| Time domain | |||
| Mean RR | 466.1 ± 167.4 | 426.8 ± 52.7 | 433.9 ± 113.8 |
| SDNN | 27.02 ± 20.56 | 24.07 ± 13.52 | 29.52 ± 28.43 |
| Mean HR | 147.2 ± 25.1 | 142.20 ± 17.9 | 140.45 ± 20.7 |
| RMSSD | 9.87 ± 9.4 | 9.81 ± 7.3 | 11.19 ± 7.7 |
| pNN50 | 0.62 ± 0.20 | 1.12 ± 4.4 | 1.45 ± 4.2 |
| Frequency domain | |||
| LF | 82.24 ± 6.7 | 80.49 ± 7.7 | 77.79 ± 9.4 |
| HF | 17.73 ± 6.7 | 19.44 ± 7.6 | 21.57 ± 9.6 |
| LF/HF | 5.68 ± 32 | 5.08 ± 2.7 | 4.49 ± 2.9 |
| Nonlinear | |||
| SD1 | 6.08 ± 3.8 | 6.98 ± 5 | 7.54 ± 5.1 |
| SD2 | 38.21 ± 28.9 | 33.41 ± 17.6 | 45.79 ± 52.9 |
| ApEn | 0.77 ± 0.28 | 0.96 ± 0.22 | 0.86 ± 0.29 |
| SampEn | 0.63 ± 0.36 | 0.88 ± 0.37 | 0.74 ± 0.36 |
RR - R-R interval; SDNN - mean standard deviation of all iRRs; HR - heart rate; RMSSD - root mean square of the sum of squared differences between iRRs; pNN50 - percentage of difference between adjacent normal R-R intervals greater than 50ms computed over the entire height of the histogram created by charting all R-R intervals; LF - low frequency; HF - high frequency; SD - standard deviation; ApEn - approximate entropy; SampEn: sample entropy;
p < 0.05 prone versus supine,
p < 0.05 supine versus restraint. Data are expressed as the mean and standard deviation.
Figure 2Decibels measured in the neonatal intensive care unit.
min - minimum; med - medium; max - maximum.
Figure 3Correlation between noise and the sympathetic activity of the autonomic nervous system.
HRV - heart rate variability; LF - low frequency.
Figure 4Mean heart rate (bpm) in different positions.
HR - heart rate.