Literature DB >> 31617455

A Combinatorial Electrochemical Biosensor for Sweat Biomarker Benchmarking.

Antra Ganguly1, Paul Rice1, Kai-Chun Lin1, Sriram Muthukumar2, Shalini Prasad1.   

Abstract

Misclassification of an acute disease condition as chronic and vice versa by electrochemical sweat biomarker sensors can cause significant psychological, emotional, and financial stress among patients. To achieve higher accuracy in distinguishing between a chronic condition and an acute condition, there is a need to establish a reference biomarker to index the actual chronic disease biomarker of interest by combinatorial sensing. This work provides the first technological proof of leveraging the chloride ion content in sweat for a combinatorial sweat biomarker benchmarking scheme. In this scheme, the sweat chloride ion has been demonstrated as the reference/indexing biomarker, while sweat cortisol has been studied as the disease biomarker of interest. Label-free affinity biosensing is achieved by using a two-electrode electrochemical system on a flexible substrate suitable for wearable applications. The electrochemical stability of the fabricated electrodes for biosensing applications was studied by open-circuit potential measurements. Attenuated total reflectance-Fourier transform infrared spectroscopy spectra validate the crosslinker-antibody binding chemistry. Concentration-dependent analyte-capture probe binding induces a modulation in the electrical properties (charge transfer resistance and double-layer capacitance) at the electrode-sweat buffer interface, which are transduced by nonfaradaic electrochemical impedance spectroscopy (EIS). Calibration dose responses for the sensor for cortisol (5-200 ng/mL) and chloride (10-100 mM) detection were evaluated in synthetic (pH 6) and pooled human sweat (R2 > 0.95). The variation in the cortisol sensor response due to fluctuations in sweat chloride levels and the significance of reporting normalized biomarker levels were demonstrated to further emphasize the need for biomarker benchmarking in electrochemical sensors.

Entities:  

Keywords:  biomarker normalization; combinatorial sweat sensor; electrochemical sweat sensing; sweat biomarker

Mesh:

Substances:

Year:  2019        PMID: 31617455     DOI: 10.1177/2472630319882003

Source DB:  PubMed          Journal:  SLAS Technol        ISSN: 2472-6303            Impact factor:   3.047


  3 in total

1.  Towards skin-acetone monitors with selective sensitivity: Dynamics of PANI-CA films.

Authors:  Anthony Annerino; Michael Faltas; Manoj Srinivasan; Pelagia-Irene Gouma
Journal:  PLoS One       Date:  2022-04-27       Impact factor: 3.240

Review 2.  Identification of Suitable Biomarkers for Stress and Emotion Detection for Future Personal Affective Wearable Sensors.

Authors:  Abdulaziz Zamkah; Terence Hui; Simon Andrews; Nilanjan Dey; Fuqian Shi; R Simon Sherratt
Journal:  Biosensors (Basel)       Date:  2020-04-16

Review 3.  Next-Generation Continuous Metabolite Sensing toward Emerging Sensor Needs.

Authors:  Ashlesha Bhide; Antra Ganguly; Tejasvi Parupudi; Mohanraj Ramasamy; Sriram Muthukumar; Shalini Prasad
Journal:  ACS Omega       Date:  2021-02-22
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.