OBJECTIVE: To evaluate organ dose and total effective dose of whole-body low-dose CT (WBLDCT) performed on different CT-scanner models in patients with multiple myeloma (MM) and to compare it to the effective dose of radiographic skeletal survey and representative diagnostic CTs.Entities:
Keywords: Effective dose; Multiple myeloma; Organ dose; Skeletal survey; Whole-body low-dose CT
Mesh:
Year: 2019 PMID: 31612246 PMCID: PMC7021660 DOI: 10.1007/s00256-019-03292-z
Source DB: PubMed Journal: Skeletal Radiol ISSN: 0364-2348 Impact factor: 2.199
Whole-body CT imaging parameters per device
| Device | No. of slices per rotation | Tube voltage (kVp) | Tube current modulation parameters | Collimation width | Rotation time (s) | Pitch |
|---|---|---|---|---|---|---|
| Revolution CT, GE | 256 | 120 | 20 (noise index) | 80 mm | 0.5 | 0.992 |
| Discovery CT750, GE | 64 | 120 | 20 (noise index) | 40 mm | 0.5 | 0.984 |
| Definition Edge, Siemens | 128 | 120 | 70 (quality reference mAs) | 38.4 mm | 0.5 | 1 |
| Definition Flash, Siemens | 128 | 120 | 70 (quality reference mAs) | 38.4 mm | 0.5 | 1 |
| SOMATOM Force, Siemens | 192 | 120 | 70 (quality reference mAs) | 57.6 mm | 0.5 | 1 |
| IQon, Philips | 128 | 120 | 12 (dose right index) | 40 mm | 0.5 | 1.171 |
Organ dose (mSv) a. Italics shows differences observed between males and females regarding the mean organ dose of thyroid, esophagus and colon
| Total | Male | Female | ||
|---|---|---|---|---|
| Head and neck | ||||
| Brain | 7.42 (1.57) | 7.44 (1.08) | 7.26 (1.38) | 0.267 |
| Eye lenses | 9.75 (2.14) | 9.85 (1.59) | 9.46 (1.84) | 0.089 |
| Salivary glands | 7.42 (1.57) | 7.44 (1.08) | 7.26 (1.38) | 0.267 |
| Thyroid | 9.41 (2.35) | 10.25 (1.55) | 8.27 (1.42) | |
| Chest | ||||
| Breast | NA | NA | 5.55 (0.86) | NA |
| Heart | 4.78 (1.34) | 4.71 (0.72) | 4.69 (0.70) | 0.852 |
| Lungs | 5.45 (1.45) | 5.40 (0.83) | 5.33 (0.79) | 0.500 |
| Gastro-intestinal system | ||||
| Esophagus | 3.72 (1.01) | 3.58 (0.52) | 3.75 (0.58) | |
| Stomach | 4.81 (1.28) | 4.71 (0.56) | 4.77 (0.72) | 0.489 |
| Small intestine | 4.06 (1.12) | 3.95 (0.47) | 4.04 (0.61) | 0.216 |
| Colon | 4.20 (1.13) | 4.06 (0.45) | 4.21 (0.63) | |
| Abdominal organs | ||||
| Liver | 4.76 (1.25) | 4.65 (0.56) | 4.74 (0.71) | 0.249 |
| Gall bladder | 4.28 (1.18) | 4.20 (0.53) | 4.22 (0.68) | 0.761 |
| Pancreas | 3.94 (1.08) | 3.82 (0.47) | 3.93 (0.58) | 0.117 |
| Spleen | 4.70 (1.21) | 4.57 (0.54) | 4.69 (0.70) | 0.140 |
| Adrenal | 4.17 (1.17) | 4.10 (0.52) | 4.10 (0.67) | 0.982 |
| Kidneys | 5.02 (1.34) | 4.96 (0.60) | 4.92 (0.73) | 0.669 |
| Urinary bladder | 4.68 (1.32) | 4.64 (0.59) | 4.58 (0.67) | 0.464 |
| Reproductive system | ||||
| Ovaries | NA | NA | 3.79 (0.59) | NA |
| Uterus | NA | NA | 3.97 (0.61) | NA |
| Testicles | NA | 8.48 (2.48) | NA | NA |
| Musculoskeletal system and skin | ||||
| Skeleton | 13.09 (2.84) | 12.72 (1.70) | 13.21 (2.09) | 0.058 |
| Red marrow | 4.30 (1.02) | 4.19 (0.48) | 4.30 (0.60) | 0.128 |
| Muscle | 5.71 (1.30) | 5.62 (0.74) | 5.66 (0.85) | 0.677 |
| Skin | 6.72 (1.43) | 6.74 (0.95) | 6.56 (1.04) | 0.169 |
aValues are means (SD)
bP-values indicate differences between groups. The independent samples T-test was used to analyze differences between groups
NA not applicable/available
Effective dose, CTDIvol and DLP between devicesa
| Revolution CT | Discovery CT750 | Definition Edge | Definition Flash | Force | IQon | |
|---|---|---|---|---|---|---|
| GE | GE | Siemens | Siemens | Siemens | Philips | |
| Effective dose (mSv) | 4.73 (4.52–4.98) | 8.37 (7.32-NA) | 4.47 (4.24–4.74) | 5.09 (4.61–6.10) | 4.34 (NA) | 5.20 (4.55–5.47) |
| CTDIvol (mGy) | 4.10 (3.61–4.41) | 6.05 (5.40-NA) | 3.91 (3.41–4.61) | 5.30 (5.19–5.67) | 3.61 (NA) | 4.20 (4.00–4.69) |
| DLP (mGy•cm) | 561 (486–614) | 784 (687-NA) | 510 (463–669) | 711 (664–719) | 515 (NA) | 569 (528–760) |
aValues are medians (IQR)
DLP dose length product, CTDI volume computed tomography dose index, NA not applicable/available
Effective doses of a skeletal survey and commonly used diagnostic CT scans at Massachusetts General Hospital (MGH)
| Exam | IV contrasta | Effective dose (mSv) | |
|---|---|---|---|
| MGH Median | ACR DIR Median | ||
| Skeletal survey (22 images) | NA | 2.04 | NA |
| CT Brain | No | 1.6 | 1.8 |
| CT Cervical spine | No | 2.1 | 2.7 |
| CT Thoracic spine | No | NA | 13.1 |
| CT Lumbar spine | No | 8.7 | 11.2 |
| CT Chest low dose protocol | No | 1.2 | 1.2 |
| CT Chest | Yes | 3.9 | 6.0 |
| CT Abdomen/pelvis | Yes | 9.0 | 10.2 |
| CT Abdomen/pelvis | No | 8.4 | 10.0 |
aCT protocol with the use of intravenous contrast