Literature DB >> 31610069

Accuracy of digital impressions for implant-supported complete-arch prosthesis, using an auxiliary geometry part-An in vitro study.

Mikel Iturrate1, Harkaitz Eguiraun2,3, Eneko Solaberrieta4.   

Abstract

OBJECTIVES: The aim of this study was to evaluate the accuracy of complete-arch digital impressions for fabrication of an implant-supported prosthesis in the edentulous maxilla using an auxiliary geometry part.
MATERIALS AND METHODS: A replica of the upper jaw of an edentulous patient with four scannable impression copings was fabricated in stainless steel. This model was scanned with an industrial non-contact 3D structured blue light 3D scanner, and the measurements of three reference distances were established as reference values. Subsequently, the model was scanned in two different scenarios (with or without an auxiliary geometry part put in place and fixed to the model) using three intraoral scanners. Measurements were taken with 3D inspection software, and a digital impression of the complete arch was built with mesh processing software by combining 2 STL files obtained with an intraoral scanner.
RESULTS: All measurements with the auxiliary geometry part gave significantly more accurate results (p < .05). Trueness improved in the three reference distances, reaching values of 8 ± 6 µm at D12 reference distance, 20 ± 11 µm at D13 and 35 ± 22 µm at D14. Precision also improved significantly with the use of the auxiliary geometry part placed on the model (p < .05). The best precision results at reference distances D13 and D14 were obtained with the True Definition Scanner.
CONCLUSIONS: The proposed methodology significantly improves the accuracy of complete-arch digital impressions in edentulous patients obtained in vitro, regardless of which scanner is used.
© 2019 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  accuracy; complete arch; digital impression; edentulous; implant-supported framework; intraoral scan

Mesh:

Year:  2019        PMID: 31610069     DOI: 10.1111/clr.13549

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  2 in total

1.  Effect of assistive devices on the precision of digital impressions for implants placed in edentulous maxilla: an in vitro study.

Authors:  Rena Masu; Shinpei Tanaka; Minoru Sanda; Keita Miyoshi; Kazuyoshi Baba
Journal:  Int J Implant Dent       Date:  2021-12-13

2.  Improved accuracy of digital implant impressions with newly designed scan bodies: an in vivo evaluation in beagle dogs.

Authors:  Ruoxuan Huang; Yuanxiang Liu; Baoxin Huang; Fengxing Zhou; Zhuofan Chen; Zhipeng Li
Journal:  BMC Oral Health       Date:  2021-12-07       Impact factor: 2.757

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.