Literature DB >> 31608493

Measuring the administered dose of particles on the facial mucosa of a realistic human model.

Mengjie Duan1,2, Li Liu1,3,4, Guillaume Da2, Evelyne Géhin2, Peter V Nielsen4, Ulla M Weinreich5,6, Borong Lin1, Yi Wang3,7, Ting Zhang8, Wei Sun8.   

Abstract

Exposure to particulate contaminants can cause serious adverse health effects. Deposition on the facial mucosa is an important path of exposure, but it is difficult to conduct direct dose measurement on real human subjects. In this study, we propose an in vitro method to assess the administered doses of micron-sized particles on the eyes and lips in which computed tomographic scanning and three-dimensional printing were used to create a model that includes a face, oropharynx, trachea, the first five generations of bronchi, and lung volume. This realistic model of a face and airway was exposed to monodispersed fluorescent particles released from an incoming jet. The administered dose of particles deposited upon the eyes and lips, as quantified by fluorescence intensity, was determined via a standard wiping protocol. The results show that, in this scenario, the administered doses normalized by source were 2.15%, 1.02%, 0.88%, 2.13%, and 1.55% for 0.6-, 1.0-, 2.0-, 3.0-, and 5.0-µm particles, respectively. The administered dose of large particles on the mucosa within a given exposure time has great significance. Moreover, the lips suffer a much greater risk of exposure than the eyes and account for more than 80% of total facial mucosa deposition. Our study provides a fast and economical method to assess the administered dose on the facial mucosa on an individual basis.
© 2019 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  3D printing; CT scanning; deposition; in vitro; mucosal exposure; occupational health

Mesh:

Substances:

Year:  2019        PMID: 31608493     DOI: 10.1111/ina.12612

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  2 in total

1.  The Need for Ocular Protection for Health Care Workers During SARS-CoV-2 Outbreak and a Hypothesis for a Potential Personal Protective Equipment.

Authors:  Lixiang Wang; Yingping Deng
Journal:  Front Public Health       Date:  2020-11-12

2.  Negative Ion Purifier Effects on Indoor Particulate Dosage to Small Airways.

Authors:  Mengjie Duan; Lijuan Wang; Xingyan Meng; Linzhi Fu; Yi Wang; Wannian Liang; Li Liu
Journal:  Int J Environ Res Public Health       Date:  2021-12-27       Impact factor: 3.390

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.