Katarzyna Pasicz1, Joanna Podgórska2, Jakub Jasieniak3, Ewa Fabiszewska1, Witold Skrzyński1, Agnieszka Anysz-Grodzicka3, Andrzej Cieszanowski3, Paweł Kukołowicz1, Iwona Grabska1. 1. Medical Physics Department, The Maria Sklodowska-Curie Institute - Oncology Center, 5 Roentgena Street, Warsaw, Poland. 2. Department of Radiology I, The Maria Sklodowska-Curie Institute - Oncology Center, 5 Roentgena Street, Warsaw, Poland; 2nd Department of Clinical Radiology, Medical University of Warsaw, 1a Banacha Street, Warsaw, Poland. Electronic address: joanna.podgorska@coi.pl. 3. Department of Radiology I, The Maria Sklodowska-Curie Institute - Oncology Center, 5 Roentgena Street, Warsaw, Poland.
Abstract
PURPOSE: The objective was to optimise the number of b-values for diffusion kurtosis imaging (DKI) of the liver and pancreas in MR examinations to ensure reliable results with the shortest possible acquisition time. METHODS: Twenty healthy volunteers underwent DKI at 3.0 T Siemens Magnetom Skyra using 7 b-values (b = 0, 200, 500, 750, 1000, 1500, 2000 s/mm2). The regions of interest (ROIs) were placed in the liver (right lobe, left lobe) and pancreas (head, tail). DKI parameters (Dapp, Kapp) for ROIs were calculated for 7 b-values utilising the nonlinear least-squares (NLLS) Marquardt-Levenberg algorithm. All calculations were repeated for ten subsets of data, with the number of b-values reduced to 4. DKI parameters calculated for subsets were compared with parameters calculated for all 7 b-values. RESULTS: The correlation coefficient between DKI parameters calculated for 7 b-values and subsets ranged from 0.65 to 1.00. The coefficient of variation (CoV) of DKI parameters calculated for a group of volunteers varied from 8% to 42% and was not affected by the reduction of the b-values number. Only one subset of data (b = 0, 500, 1500 and 2000 s/mm2) simultaneously met two criteria: no statistical difference (p < 0.05) from results obtained for 7 b-values and very good correlation with them. CONCLUSIONS: DKI acquisition with 4 b-values (b = 0, 500, 1500 and 2000 s/mm2), compared to DKI acquisition utilising 7 b-values, allowed for the reduction of acquisition time by 36%, without affecting the calculated DKI parameters.
PURPOSE: The objective was to optimise the number of b-values for diffusion kurtosis imaging (DKI) of the liver and pancreas in MR examinations to ensure reliable results with the shortest possible acquisition time. METHODS: Twenty healthy volunteers underwent DKI at 3.0 T Siemens Magnetom Skyra using 7 b-values (b = 0, 200, 500, 750, 1000, 1500, 2000 s/mm2). The regions of interest (ROIs) were placed in the liver (right lobe, left lobe) and pancreas (head, tail). DKI parameters (Dapp, Kapp) for ROIs were calculated for 7 b-values utilising the nonlinear least-squares (NLLS) Marquardt-Levenberg algorithm. All calculations were repeated for ten subsets of data, with the number of b-values reduced to 4. DKI parameters calculated for subsets were compared with parameters calculated for all 7 b-values. RESULTS: The correlation coefficient between DKI parameters calculated for 7 b-values and subsets ranged from 0.65 to 1.00. The coefficient of variation (CoV) of DKI parameters calculated for a group of volunteers varied from 8% to 42% and was not affected by the reduction of the b-values number. Only one subset of data (b = 0, 500, 1500 and 2000 s/mm2) simultaneously met two criteria: no statistical difference (p < 0.05) from results obtained for 7 b-values and very good correlation with them. CONCLUSIONS: DKI acquisition with 4 b-values (b = 0, 500, 1500 and 2000 s/mm2), compared to DKI acquisition utilising 7 b-values, allowed for the reduction of acquisition time by 36%, without affecting the calculated DKI parameters.