Literature DB >> 31600608

Correlation-based ECG Artifact Correction from Single Channel EEG using Modified Variational Mode Decomposition.

Chinmayee Dora1, Pradyut Kumar Biswal2.   

Abstract

BACKGROUND AND
OBJECTIVE: Ambulatory based healthcare system use limited electrodes for electroencephalogram (EEG) acquisition at concerned electrode position, to minimize the instrumentation and computational complexity. But, again the possibility of contamination is inevitable depending on the electrode position on the scalp. This paper proposes an electrocardiogram (ECG) artifact correction algorithm in the absence of coherent ECG for automatic analysis/diagnosis of the acquired contaminated single channel EEG signal.
METHODS: The proposed algorithm uses an enhanced and modified version of signal decomposition i.e. modified variational mode decomposition (mVMD) to obtain band limited intrinsic mode functions (BLIMFs) from EEG epoch. The mVMD is found to be useful when the signal contains properties that are correlated. Further, exploiting the correlation among the obtained mode functions the ECG artifact components are identified. An ECG reference is estimated and QRS complexes are suppressed. The effective EEG reconstruction is performed by simply adding the remaining BLIMFs to QRS complex suppressed estimated reference. This is owing to the robust reconstruction feature provided by mVMD.
RESULTS: Upon the comparative evaluation for both real and semi-simulated dataset, the proposed algorithm is providing less distortion to the EEG brain activity frequency bands, and is also less computationally intensive than the existing Ensembled empirical mode decomposition (EEMD) based algorithm that requires ECG reference channel. Evaluation of semi-simulated dataset obtained an average correlation of 97% between EEG signals before contamination and after correction of ECG artifact.
CONCLUSION: The proposed algorithm efficiently corrects the ECG artifact from EEG while overcoming the limitations such as, (1) requirement of a reference ECG channel, (2) requirement of R-R interval or amplitude thresholding for QRS complex identification.
Copyright © 2019 Elsevier B.V. All rights reserved.

Keywords:  Correlation; ECG; EEG; EEMD; artifact; modified VMD

Year:  2019        PMID: 31600608     DOI: 10.1016/j.cmpb.2019.105092

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  4 in total

Review 1.  Formulation of the Challenges in Brain-Computer Interfaces as Optimization Problems-A Review.

Authors:  Shireen Fathima; Sheela Kiran Kore
Journal:  Front Neurosci       Date:  2021-01-21       Impact factor: 4.677

2.  Hybrid Method of Automated EEG Signals' Selection Using Reversed Correlation Algorithm for Improved Classification of Emotions.

Authors:  Agnieszka Wosiak; Aleksandra Dura
Journal:  Sensors (Basel)       Date:  2020-12-10       Impact factor: 3.576

3.  Potential of Overcomplete Wavelet Frame Expansion for Facilitating Electroencephalogram Information Mining.

Authors:  Wanshan Liu; Xiaoyue Guo; Binqiang Chen; Wangpeng He
Journal:  Front Neurosci       Date:  2022-01-12       Impact factor: 4.677

Review 4.  A review of progress and an advanced method for shock advice algorithms in automated external defibrillators.

Authors:  Minh Tuan Nguyen; Thu-Hang T Nguyen; Hai-Chau Le
Journal:  Biomed Eng Online       Date:  2022-04-02       Impact factor: 2.819

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.