Literature DB >> 31594607

Ultrasensitive fluorescent detection of HTLV-II DNA based on magnetic nanoparticles and atom transfer radical polymerization signal amplification.

Xiaoke Zheng1, Liying Zhao1, Dongxiao Wen1, Xiaolan Wang1, Huaixia Yang1, Weisheng Feng2, Jinming Kong3.   

Abstract

Human T-lymphotropic virus type II (HTLV-II) is a crucial retrovirus that is closely associated with a variety of human diseases. Herein, an ultrasensitive fluorescent HTLV-II DNA detection strategy was developed for the first time based on magnetic nanoparticles (MNPs) and atom transfer radical polymerization (ATRP) amplification. In this approach, hairpin DNA probes (pDNA) labelled with 5' thiol and 3' azide group terminally were immobilized on amino group modified MNPs surface through sulfo-N-succinimidyl-4-maleimidobutyrate sodium salt (sulfo-GMBS) cross-linkers. In the presence of target DNAs (tDNA), pDNA hybridized with tDNA to form double-stranded DNA, and therefore its azide group was away from the MNPs surface. Subsequently, to initiate ATRP reaction, initiators were introduced into the pDNA by a Cu (I)-catalyzed alkyne-azide cycloaddition (CuAAC). Then, large numbers of 9-anthracenylmethyl methacrylate polymer (pAMMA) were successfully labelled on the MNPs surface, resulting in significant amplification of the fluorescence signal. Under optimized conditions, the fluorescence signal was proportional to the logarithm of the concentration of tDNA over the range from 1 fM to 1 nM, with a detection limit of 0.22 fM. Moreover, this strategy was capable of discriminating mismatched bases and detecting HTLV-II DNA in human serum samples. By virtue of the high sensitivity, selectivity, simplicity and economy, this ultrasensitive biosensor demonstrates great potential for biomedical research and early clinical diagnosis.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Atom transfer radical polymerization; Fluorescent biosensor; HTLV-II DNA; Magnetic nanoparticles; Signal amplification

Mesh:

Substances:

Year:  2019        PMID: 31594607     DOI: 10.1016/j.talanta.2019.120290

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  A one step method for isolation of genomic DNA using multi-amino modified magnetic nanoparticles.

Authors:  Jia Xu; Dan Chen; Yuan Yang; Hongjian Gong; Wenqi Gao; Han Xiao
Journal:  RSC Adv       Date:  2021-01-15       Impact factor: 3.361

Review 2.  Metal-organic frameworks for virus detection.

Authors:  Ying Wang; Yaqin Hu; Qunye He; Jianhua Yan; Hongjie Xiong; Nachuan Wen; Shundong Cai; Dongming Peng; Yanfei Liu; Zhenbao Liu
Journal:  Biosens Bioelectron       Date:  2020-09-14       Impact factor: 10.618

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.