| Literature DB >> 31591646 |
E de Boer1, I M Nijholt1, S Jansen1, M A Edens2, S Walen3, J W K van den Berg3, M F Boomsma4.
Abstract
OBJECTIVES: The aim of this study was to assess the effect of hybrid iterative reconstruction and post processing on emphysema quantification in low-dose CT scans of COPD patients using pulmonary function tests (PFT) as a reference.Entities:
Keywords: Chronic Obstructive Pulmonary Disease; Computed Tomography; Computer assisted image processing; Emphysema; Respiratory function tests
Year: 2019 PMID: 31591646 PMCID: PMC6779684 DOI: 10.1186/s13244-019-0776-9
Source DB: PubMed Journal: Insights Imaging ISSN: 1869-4101
Fig. 1Magnification of the lung parenchyma in a CT scan with the seven different iDose4 levels in ISP6: upper row iDose4 level 1 to 3; middle row: iDose4 level 4 to 6; bottom: iDose4 level 7
Fig. 2Magnification of Fig. 1, left: iDose4 level 1 and right iDose4 level 6
Characteristics and demographics of the study participants
| Demographics | |
| Sex (male, %) | 15 (65.2%) |
| Age (mean in years, SD) | 67.8 (± 9.9) |
| Anthropometry | |
| BMI (median in kg/m2, p25–p75) | 27.7 (21.8–29.6) |
| Smoking | |
| Smoker/former smoker (yes, %) | 15 (65.2%) |
| Pack years (median, p25–p75) | 20.0 (0.0–38.0) |
| Packages weekly (median, p25–p75) | 0.38 (0–0.78) |
| Pulmonary function | |
| GOLD stage ( | |
| 1 | 3 (13.0%) |
| 2 | 10 (43.5%) |
| 3 | 6 (26.1%) |
| 4 | 4 (17.4%) |
| FEV1 (mean in L, SD) | 1.57 (± 0.72) |
| FEV1% pred (mean %, SD) | 54.2 (± 22.5) |
| FVC (mean in L, SD) | 3.35 (± 1.12) |
| FEV1/FVC (mean, SD) | 0.47 (± 0.15) |
| Questionnaires | |
| MRC | |
| 0 | 3 (14.3%) |
| 1 | 8 (38.1%) |
| 2 | 1 (4.8%) |
| 3 | 5 (23.8%) |
| 4 | 4 (19.0%) |
| CCQ | 2.28 (± 1.09) |
BMI body mass index, pack years packs smoked per day × years as a smoker, packages weekly pack years/52, GOLD global initiative for chronic obstructive pulmonary disease, FEV1 forced expiratory volume in 1 s, FEV1% pred forced expiratory volume in the first second as percentage of predicted, FVC forced vital capacity, FEV1/FVC ratio of FEV1 divided by the forced vital capacity, MRC Medical Research Council dyspnea scale, CCQ Clinical COPD Questionnaire
aTwo participants did not fill in the MRC and CCQ
Fig. 3Profile plot of %LAA-950 for the seven levels within ISP6, ISP7 with and without de-noising. %LAA-950 percentage of lung voxels with attenuation < − 950 Hounsfield units, ISP IntelliSpace Portal, ISP7d ISP7 with denoising
Fig. 4Boxplot of %LAA-950 for the various iDose4 levels of ISP6 and ISP7 with and without denoising (n = 22, one patient had missing values). %LAA-950 percentage of lung voxels with attenuation < − 950 Hounsfield units, ISP IntelliSpace Portal
Spearman correlation coefficients
| %LAA-950 per iDose4 level | |||||||
|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | |
| Body mass index | |||||||
| BMI ISP6 | − .439* | − .439* | − .429* | − .426* | − .418* | − .405 | − .416* |
| BMI ISP7 | − .455* | − .450* | − .450* | − .444* | − .433* | − .444* | − .438* |
| BMI ISP7d | − .424* | − .424* | − .424* | − .424* | − .408 | − .423* | − .404 |
| GOLD stage | |||||||
| GOLD ISP6 | .489* | .489* | .489* | .489* | .497* | .513* | .518* |
| GOLD ISP7 | .456* | .467* | .467* | .467* | .492* | .469* | .469* |
| GOLD ISP7d | .469* | .469* | .469* | .469* | .525* | .492* | .493* |
| Pulmonary function tests | |||||||
| FEV1 ISP6 | − .458* | − .458* | − .464* | − .465* | − .475* | − .507* | − .510* |
| FEV1 ISP7 | − .430* | − .442* | − .442* | − .445* | − .471* | − .453* | − .460* |
| FEV1 ISP7d | − .475* | − .475* | − .475* | − .475* | − .509* | − .488* | − .493* |
| FEV1% ISP6 | − .551** | − .551** | − .554** | − .556** | − .564** | − .588** | − .591** |
| FEV1% ISP7 | − .526** | − .532** | − .532** | − .534** | − .544** | − .539** | − .542** |
| FEV1% ISP7d | − .544** | − .544** | − .544** | − .544** | − .590** | − .574** | − .572** |
| FVC ISP6 | .090 | .090 | .101 | .104 | .097 | .069 | .080 |
| FVC ISP7 | .125 | .109 | .109 | .114 | .092 | .122 | .115 |
| FVC ISP7d | .101 | .101 | .101 | .101 | .053 | .105 | .105 |
| FEV1/FVC ISP6 | − .809** | − .809** | − .820** | − .823** | − .825** | − .838** | − .845** |
| FEV1/FVC ISP7 | − .799** | − .800** | − .800** | − .807** | − .812** | − .813** | − .814** |
| FEV1/FVC ISP7d | − .814** | − .814** | − .814** | − .814** | − .834** | − .841** | − .838** |
| CCQ | |||||||
| CCQ ISP6 | .499* | .499* | .521* | .521* | .531* | .562** | .579** |
| CCQ ISP7 | .507* | .510* | .510* | .510* | .523* | .550** | .560** |
| CCQ ISP7d | .566** | .566** | .566** | .566** | .550* | .572** | .607** |
ISP IntelliSpace Portal, ISP7d ISP7 with denoising filter, %LAA-950 percentage of lung voxels with attenuation < − 950 HU, BMI body mass index, FEV forced expiratory volume in 1 s, FEV% pred forced expiratory volume in the first second as percentage of predicted, FVC functional vital capacity, CCQ Clinical COPD Questionnaire scores
*p < 0.05; **p < 0.001