Literature DB >> 31587502

Better continuity of the facial nerve demonstrated in the temporal bone on three-dimensional T1-weighted imaging with volume isotropic turbo spin echo acquisition than that with fast field echo at 3.0 tesla MRI.

Jun Haneda1, Kazuhiro Ishikawa2, Kouichirou Okamoto3.   

Abstract

INTRODUCTION: Three-dimensional (3D) T1-weighted imaging (T1WI) is used for evaluation of the facial nerve. The signal intensity of normal and pathological facial nerves has been well evaluated at both 1.5T and 3.0T MRI after gadolinium (Gd)-enhancement with various pulse sequences. However, the continuity of the facial nerve has not been evaluated on 3D-T1WI. This study aims to compare the continuity of the normal facial nerve in the temporal bone demonstrated on T1-weighted volume isotropic turbo spin echo acquisition (T1-VISTA), which is a spin-echo sequence, to that on T1-weighted fast field echo (T1-FFE), which is a gradient-echo sequence, at 3.0T MRI.
METHODS: Forty-four normal facial nerves in 22 healthy volunteers were imaged with both sequences using 3.0T MRI without Gd-enhancement. The facial nerves were evaluated visually by two neuroradiologists in four anatomical segments with a 3-point grading system of continuity. The continuity was assessed by summing the grades of the four segments as a total score. The grades at each segment and the total scores were compared statistically between the T1-VISTA and T1-FFE.
RESULTS: The grades in all segments and the total score were significantly higher with T1-VISTA than those with T1-FFE.
CONCLUSIONS: T1-VISTA was superior to demonstrate the facial nerve as a continuous anatomical structure in the temporal bone at 3.0T MRI.
© 2019 The Royal Australian and New Zealand College of Radiologists.

Entities:  

Keywords:  facial nerve; magnetic resonance imaging; temporal bone

Mesh:

Year:  2019        PMID: 31587502     DOI: 10.1111/1754-9485.12962

Source DB:  PubMed          Journal:  J Med Imaging Radiat Oncol        ISSN: 1754-9477            Impact factor:   1.735


  5 in total

1.  Automatic Segmentation of Intracochlear Anatomy in MR Images Using a Weighted Active Shape Model.

Authors:  Yubo Fan; Rueben A Banalagay; Nathan D Cass; Jack H Noble; Kareem O Tawfik; Robert F Labadie; Benoit M Dawant
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2021-11

2.  Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques.

Authors:  Johannes Taeger; Franz Tassilo Müller-Graff; Lukas Ilgen; Phillip Schendzielorz; Rudolf Hagen; Tilman Neun; Kristen Rak
Journal:  OTO Open       Date:  2021-09-24

3.  Improvement of the Diagnostic Performance of Facial Neuritis Using Contrast-Enhanced 3D T1 Black-Blood Imaging: Comparison with Contrast-Enhanced 3D T1-Spoiled Gradient-Echo Imaging.

Authors:  Seun-Ah Lee; Sang-Won Jo; Suk-Ki Chang; Ki-Han Kwon
Journal:  J Clin Med       Date:  2021-04-24       Impact factor: 4.241

4.  Application of intentional facial nerve stimulation during cochlear implantation as an electrophysiological tool to estimate the intracochlear electrode position.

Authors:  David P Herrmann; Franz-Tassilo Müller-Graff; Stefan Kaulitz; Mario Cebulla; Anja Kurz; Rudolf Hagen; Tilmann Neun; Kristen Rak
Journal:  Sci Rep       Date:  2022-08-04       Impact factor: 4.996

5.  The Application of Contrast-Enhanced 3D-STIR-VISTA MR Imaging of the Brachial Plexus.

Authors:  Dingsheng Han; Yanru Zhou; Lan Zhang; Jiajia Zhang
Journal:  J Belg Soc Radiol       Date:  2022-09-05       Impact factor: 1.912

  5 in total