A Comparison of Venous versus Capillary Blood Samples when Measuring Blood Glucose Using a Point-of-Care, Capillary-Based Glucometer.

Jessica Topping1, Matthew Reardon1, Jake Coleman1, Brian Hunter1, Haruka Shojima-Perera1, Liz Thyer1, Paul Simpson1.   

Abstract

BACKGROUND: Blood glucose level (BGL) is routinely assessed by paramedics in the out-of-hospital setting. Most commonly, BGL is measured using a blood sample of capillary origin analyzed by a hand-held, point-of-care glucometer. In some clinical circumstances, the capillary sample may be replaced by blood of venous origin. Given most point-of-care glucometers are engineered to analyze capillary blood samples, the use of venous blood instead of capillary may lead to inaccurate or misleading measurements. HYPOTHESIS/PROBLEM: The aim of this prospective study was to compare mean difference in BGL between venous and capillary blood from healthy volunteers when measured using a capillary-based, hand-held, point-of-care glucometer.
METHODS: Using a prospective observational comparison design, 36 healthy participants provided paired samples of blood, one venous and the other capillary, taken near simultaneously. The BGL values were similar between the two groups. The capillary group had a range of 4.3mmol/l, with the lowest value being 4.4mmol/l and 8.7mmol/l the highest. The venous group had a range of 2.7mmol/l, with the lowest value being 4.1mmol/l and 7.0mmol/l the highest.For the primary research question, the mean BGL for the venous sample group was 5.3mmol/l (SD = 0.6), compared to 5.6mmol/l (SD = 0.8) for the capillary group. This represented a statistically significant difference of 0.3mmol/l (P = .04), but it did not reach the a priori established point of clinical significance (1.0mmol/l). Pearson's correlation coefficient for capillary versus venous indicated moderate correlation (r = 0.42).
CONCLUSION: In healthy, non-fasted people in a non-clinical setting, a statistically significant, but not clinically significant, difference was found between venous- and capillary-derived BGL when measured using a point-of-care, capillary-based glucometer. Correlation between the two was moderate. In this context, using venous samples in a capillary-based glucometer is reasonable providing the venous sample can be gathered without exposure of the clinician to risk of needle-stick injury. In clinical settings where physiological derangement or acute illness is present, capillary sampling would remain the optimal approach.

Entities:  

Keywords:  blood glucose level; capillary; prehospital; venous

Mesh:

Substances:

Year:  2019        PMID: 31578946     DOI: 10.1017/S1049023X19004850

Source DB:  PubMed          Journal:  Prehosp Disaster Med        ISSN: 1049-023X            Impact factor:   2.040


  2 in total

1.  The Ten-Year Risk Prediction for Cardiovascular Disease for Malaysian Adults Using the Laboratory-Based and Office-Based (Globorisk) Prediction Model.

Authors:  Che Muhammad Nur Hidayat Che Nawi; Mohd Azahadi Omar; Thomas Keegan; Yong-Poh Yu; Kamarul Imran Musa
Journal:  Medicina (Kaunas)       Date:  2022-05-12       Impact factor: 2.948

2.  Effect of thiamine supplementation on glycaemic outcomes in adults with type 2 diabetes: a systematic review and meta-analysis.

Authors:  Arti Muley; Ritin Fernandez; Heidi Green; Prasad Muley
Journal:  BMJ Open       Date:  2022-08-25       Impact factor: 3.006

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.