Literature DB >> 31578544

Need for pacemaker implantation in patients with normal QRS duration immediately after transcatheter aortic valve implantation.

Simon Schoechlin1, Fares Jalil1, Thomas Blum1, Philipp Ruile1, Manuel Hein1, Thomas G Nührenberg1, Thomas Arentz1, Franz-Josef Neumann1.   

Abstract

AIMS: We sought to assess the need for permanent pacemaker implantation (PPI) in patients with QRS <120 ms in electrocardiogram (ECG) after transcatheter aortic valve implantation (TAVI). METHODS AND
RESULTS: We retrospectively analysed 1139 consecutive patients who underwent transfemoral TAVI between 2008 and 2016, receiving different valve types. All patients were surveyed by continuous ECG monitoring for 48 h, 12-lead ECGs starting immediately after procedure, as well as 24-h Holter recording the day before discharge. Indication for PPI was at the discretion of the attending physician. Among 760 patients with QRS <120 ms prior to the TAVI procedure, 400 patients showed QRS <120 ms immediately after procedure, whereas 360 patients had QRS ≥120 ms. In the group with QRS <120 ms, PPI was performed in 34 patients [8.5%; 95% confidence interval (CI) 5.6-11.2%] during the first week. Eight of the PPIs in the group with QRS <120 ms (2%; CI 0.8-3.5%) fulfilled Class I indications for PPI after TAVI, whereas 26 PPIs had different indications [left bundle branch block, sick sinus, low-grade atrioventricular (AV) block]. Complete AV block developed in three patients of the group of QRS <120 ms (0.75%; CI 0.0-1.7%), which in all cases occurred after the 48 h-surveillance period. During 1-year follow-up, 11 PPIs were performed (2.8%; CI 1.2-4.5%), thereof three PPI for Class I indications including one complete AV block.
CONCLUSION: In patients with QRS duration <120 ms immediately after TAVI, the risk for complete AV block was low during the first week after TAVI and 1-year follow-up. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author(s) 2019. For permissions, please email: journals.permissions@oup.com.

Entities:  

Keywords:  Pacemaker implantation; QRS duration; Transcatheter aortic valve implantation

Mesh:

Year:  2019        PMID: 31578544     DOI: 10.1093/europace/euz261

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  2 in total

1.  Female gender and the clinical and periprocedural profile and clinical outcomes of transcatheter aortic valve implantation: experiences of a tertiary Polish centre.

Authors:  Krzysztof Wilczek; Piotr Chodór; Maciej Dyrbuś; Michał Hawranek; Łukasz Włoch; Łukasz Pyka; Tomasz Hrapkowicz; Michał Zembala; Zbigniew Kalarus; Mariusz Gąsior
Journal:  Postepy Kardiol Interwencyjnej       Date:  2020-12-29       Impact factor: 1.426

2.  Risk Stratification for Pacemaker Implantation after Transcatheter Aortic Valve Implantation in Patients with Right Bundle Branch Block.

Authors:  Simon Schoechlin; Martin Eichenlaub; Björn Müller-Edenborn; Franz-Josef Neumann; Thomas Arentz; Dirk Westermann; Amir Jadidi
Journal:  J Clin Med       Date:  2022-09-22       Impact factor: 4.964

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.