Literature DB >> 31578129

Test-retest reliability measures for curve data: an overview with recommendations and supplementary code.

Alessia Pini1,2, Jonas L Markström3, Lina Schelin1.   

Abstract

The purpose of this paper is to provide an overview of available methods for reliability investigations when the outcome of interest is a curve. Curve data, or functional data, is commonly collected in biomechanical research in order to better understand different aspects of human movement. Using recent statistical developments, curve data can be analysed in its most detailed form, as functions. However, an overview of appropriate statistical methods for assessing reliability of curve data is lacking. A review of contemporary literature of reliability measures for curve data within the fields of biomechanics and statistics identified the following methods: coefficient of multiple correlation, functional limits of agreement, measures of distance and similarity, and integrated pointwise indices (an extension of univariate reliability measures to curve data, inclusive of Pearson correlation, intraclass correlation, and standard error of measurement). These methods are briefly presented, implemented (R-code available as supplementary material) and evaluated on simulated data to highlight advantages and disadvantages of the methods. Among the identified methods, the integrated intraclass correlation and standard error of measurement are recommended. These methods are straightforward to implement, enable results over the domain, and consider variation between individuals, which the other methods partly neglect.

Entities:  

Keywords:  Agreement; functional data; kinematics; similarity

Mesh:

Year:  2019        PMID: 31578129     DOI: 10.1080/14763141.2019.1655089

Source DB:  PubMed          Journal:  Sports Biomech        ISSN: 1476-3141            Impact factor:   2.832


  3 in total

1.  Atypical Lower Limb Mechanics During Weight Acceptance of Stair Descent at Different Time Frames After Anterior Cruciate Ligament Reconstruction.

Authors:  Jonas L Markström; Dario G Liebermann; Lina Schelin; Charlotte K Häger
Journal:  Am J Sports Med       Date:  2022-05-23       Impact factor: 7.010

2.  Agreement between An Inertia and Optical Based Motion Capture during the VU-Return-to-Play- Field-Test.

Authors:  Chris Richter; Katherine A J Daniels; Enda King; Andrew Franklyn-Miller
Journal:  Sensors (Basel)       Date:  2020-02-04       Impact factor: 3.576

3.  Development and Validation of a Wearable Inertial Sensors-Based Automated System for Assessing Work-Related Musculoskeletal Disorders in the Workspace.

Authors:  Chunxi Huang; Woojoo Kim; Yanxin Zhang; Shuping Xiong
Journal:  Int J Environ Res Public Health       Date:  2020-08-20       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.