Literature DB >> 31577917

Lateral flow aptasensor for progesterone: Competitive target recognition and displacement of short complementary sequences.

Mohammed N Alnajrani1, Omar A Alsager2.   

Abstract

There is a pressing need for simple and accurate analytical tools to assess the level of EDCs in environmental samples. In this work, a simple and highly sensitive competitive lateral flow assay (LFA) was developed for progesterone (P4). Gold nanoparticles (AuNPs) were functionalized with a previously isolated 60-mer aptamer for P4 and further hybridized with 8-mer complementary sequence modified with biotin. In the absence of P4, AuNP-duplexed aptamer conjugates are capture by a test line made with streptavidin. Conformational change within aptamer sequence upon target recognition causes the release of the biotinylated complementary sequence and disappearance of the colored test line. By optimizing the hybridization location of the 8-mer biotinylated sequences, the sensitivity of sensor was improved by 20-folds to achieve 5 nM detection level of P4 in buffer and spiked tap water samples. The simply fabricated sensor demonstrated a dynamic range in the lower nanomolar range and excellent selectivity against potential interfering molecules including the closely similar 17β-estradiol (E2). The sensor can be used as a fast screening tool to assess the level of P4 in water. Implementing the developed assay avoids applying laborious extraction procedures and lengthily analysis by conventional chromatography based instruments.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Aptamer; Colorimetric; Competitive detection; Lateral flow assay; Progesterone; Short sequences

Year:  2019        PMID: 31577917     DOI: 10.1016/j.ab.2019.113461

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  4 in total

Review 1.  Development of nucleic acid aptamer-based lateral flow assays: A robust platform for cost-effective point-of-care diagnosis.

Authors:  Tao Wang; Lanmei Chen; Arpitha Chikkanna; Suxiang Chen; Isabell Brusius; Nabayet Sbuh; Rakesh N Veedu
Journal:  Theranostics       Date:  2021-03-05       Impact factor: 11.556

Review 2.  Progress in Biosensors for the Point-of-Care Diagnosis of COVID-19.

Authors:  Miroslav Pohanka
Journal:  Sensors (Basel)       Date:  2022-09-29       Impact factor: 3.847

Review 3.  Aptasensors for Point-of-Care Detection of Small Molecules.

Authors:  Marc Prante; Ester Segal; Thomas Scheper; Janina Bahnemann; Johanna Walter
Journal:  Biosensors (Basel)       Date:  2020-08-26

Review 4.  Aptamer-Based Lateral Flow Assays: Current Trends in Clinical Diagnostic Rapid Tests.

Authors:  Marjan Majdinasab; Mihaela Badea; Jean Louis Marty
Journal:  Pharmaceuticals (Basel)       Date:  2022-01-13
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.