Literature DB >> 31577866

Evaluation of the AllType kit for HLA typing using the Ion Torrent S5 XL platform.

Marine Cargou1,2,3, Mamy Ralazamahaleo1, Laura Blouin1, Isabelle Top4, Vincent Elsermans4, Marco Andreani5, Gwendaline Guidicelli1, Jonathan Visentin1,2,3.   

Abstract

HLA genotyping by next-generation sequencing is now widely performed. We aimed at evaluating the performance of the One Lambda AllType kit using Thermo Fisher Scientific reagents on the Ion S5 XL platform. Reads were analyzed using the TypeStream Visual software. We performed 15 runs between April and September 2018 to type DNA at the HLA-A/B/C/DRB1/3/4/5/DQA1/DQB1/DPA1/DPB1 loci from 340 samples and 15 positive controls. We observed only seven (0.1%) critical mistakes among the 6009 alleles typed, corresponding to two allele dropouts, one false heterozygous typing assignment, and four phasing abnormalities. Among the 1793 presumably new alleles detected by the analysis software, 11 displayed exon mismatches, of which nine were confirmed as new alleles and two had been described previously. Intron mismatches were observed among the remaining presumably new alleles, of which 371 were considered as probably new, and 1411 were rejected for at least one sequence feature such as homopolymers (n = 1206), nucleotide doublet repeats (n = 26), low read depth (<200 reads, n = 93), high background (>20%, n = 79), or phasing abnormalities (n = 7). A comparison of the AllType results with those obtained using other methods at the second-field resolution level showed 99.5% (1497/1504) concordance for the HLA-A/B/C/DRB1/DQB1/DPB1 loci. Similar agreement was observed between the HLA-C or HLA-DRB3/4/5 results and common linkage disequilibrium, with 96.6% (657/680) and 97.2% (530/545) concordance, respectively. Therefore, the AllType kit used with the Ion S5 XL platform displayed satisfactory performance for HLA typing in current clinical practice.
© 2019 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  HLA; HLA typing; NGS; allogeneic HSCT; transplantation

Mesh:

Substances:

Year:  2019        PMID: 31577866     DOI: 10.1111/tan.13708

Source DB:  PubMed          Journal:  HLA        ISSN: 2059-2302            Impact factor:   4.513


  3 in total

Review 1.  A long road/read to rapid high-resolution HLA typing: The nanopore perspective.

Authors:  Chang Liu
Journal:  Hum Immunol       Date:  2020-05-01       Impact factor: 2.211

2.  Performance of a multiplexed amplicon-based next-generation sequencing assay for HLA typing.

Authors:  Chang Liu; Brian F Duffy; Eric T Weimer; Maureen C Montgomery; Jo-Ellen Jennemann; Rachel Hill; Donna Phelan; Lindsay Lay; Bijal A Parikh
Journal:  PLoS One       Date:  2020-04-23       Impact factor: 3.240

3.  HLA allele frequencies and susceptibility to COVID-19 in a group of 99 Italian patients.

Authors:  Antonio Novelli; Marco Andreani; Michela Biancolella; Laura Liberatoscioli; Chiara Passarelli; Vito Luigi Colona; Paola Rogliani; Francesca Leonardis; Andrea Campana; Rita Carsetti; Massimo Andreoni; Sergio Bernardini; Giuseppe Novelli; Franco Locatelli
Journal:  HLA       Date:  2020-09-03       Impact factor: 8.762

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.