Literature DB >> 3156861

Is compliance mismatch the major cause of anastomotic arterial aneurysms? Analysis of 42 cases.

D G Mehigan, B Fitzpatrick, H I Browne, D J Bouchier-Hayes.   

Abstract

In 1,348 anastomoses carried out prior to 1976 at St. Laurence's Hospital, Dublin, 36 anastomotic aneurysms developed for an incidence of 2.7%. Six further anastomotic aneurysms occurred following repair of anastomotic false aneurysms. Suture material failure, infection or lymphatic leakage were not associated with aneurysm formation. Twenty three aneurysms occurred in eight hundred and sixty Dacron to artery anastomoses while 6 occurred in 420 vein to artery anastomoses. Anastomotic false aneurysms were found only with the Dacron to artery anastomoses. Only 9 of 590 anastomoses performed for abdominal aortic aneurysm developed false aneurysms while 14 occurred in 270 for occlusive atherosclerosis. We have concluded that compliance mismatch producing anastomotic shear stress damages the arterial wall. This structural impairment permits tearing out of sutures from the vessel wall. The process is facilitated by prior loss of structural integrity of the vessel wall.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3156861

Source DB:  PubMed          Journal:  J Cardiovasc Surg (Torino)        ISSN: 0021-9509            Impact factor:   1.888


  12 in total

1.  Progress in the treatment of anastomotic aneurysms.

Authors:  R Courbier; R Aboukhater
Journal:  World J Surg       Date:  1988-12       Impact factor: 3.352

Review 2.  Small Diameter Xenogeneic Extracellular Matrix Scaffolds for Vascular Applications.

Authors:  Manuela Lopera Higuita; Leigh G Griffiths
Journal:  Tissue Eng Part B Rev       Date:  2019-11-27       Impact factor: 6.389

3.  External aortic root support: a histological and mechanical study in sheep.

Authors:  Peter Verbrugghe; Erik Verbeken; John Pepper; Tom Treasure; Bart Meyns; Bart Meuris; Paul Herijgers; Filip Rega
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-04-26

4.  In vivo determination of human arterial compliance: preliminary investigation of a new technique.

Authors:  M E Hansen; E K Yucel; J Megerman; G J L'Italien; W M Abbott; A C Waltman
Journal:  Cardiovasc Intervent Radiol       Date:  1994 Jan-Feb       Impact factor: 2.740

5.  Recurrent femoral anastomotic aneurysms. A 30-year experience.

Authors:  C B Ernst; J P Elliott; C J Ryan; G Abu-Hamad; B C Tilley; R K Murphy; R F Smith; D J Reddy; D E Szilagyi
Journal:  Ann Surg       Date:  1988-10       Impact factor: 12.969

6.  In vitro study of haemodynamics in a giant saccular aneurysm model: influence of flow dynamics in the parent vessel and effects of coil embolisation.

Authors:  Y P Gobin; J L Counord; P Flaud; J Duffaux
Journal:  Neuroradiology       Date:  1994-10       Impact factor: 2.804

7.  Vascular suture line wrapping for Aortoiliac anastomoses following open surgical repair of Infrarenal Behçet's Aortoiliac aneurysms.

Authors:  Ahmed Mousa; Ibrahim Hanbal; Alaa Sharabi; Mohammed A Nasr; Abdelfattah K Nassar; Mai A Elkalla
Journal:  Orphanet J Rare Dis       Date:  2019-04-15       Impact factor: 4.123

8.  Tissue engineered bovine saphenous vein extracellular matrix scaffolds produced via antigen removal achieve high in vivo patency rates.

Authors:  Manuela Lopera Higuita; Juan F Lopera Giraldo; Tiffany L Sarrafian; Leigh G Griffiths
Journal:  Acta Biomater       Date:  2021-06-27       Impact factor: 10.633

9.  Uninfected para-anastomotic aneurysms after infrarenal aortic grafting.

Authors:  Paolo Bianchi; Giovanni Nano; Francesco Cusmai; Fabio Ramponi; Silvia Stegher; Daniela Dell'Aglio; Giovanni Malacrida; Domenico G Tealdi
Journal:  Yonsei Med J       Date:  2009-04-30       Impact factor: 2.759

10.  Total aortic arch replacement: superior ventriculo-arterial coupling with decellularized allografts compared with conventional prostheses.

Authors:  Alexander Weymann; Tamás Radovits; Bastian Schmack; Sevil Korkmaz; Shiliang Li; Nicole Chaimow; Ines Pätzold; Peter Moritz Becher; István Hartyánszky; Pál Soós; Gergő Merkely; Balázs Tamás Németh; Roland Istók; Gábor Veres; Béla Merkely; Konstantin Terytze; Matthias Karck; Gábor Szabó
Journal:  PLoS One       Date:  2014-07-31       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.