Literature DB >> 31565829

A novel sample design for determining color compatibility between layered resin composite and vita shade guides.

Eman H Ismail1,2, Deborah V Dawson3,4, Rodrigo R Maia5.   

Abstract

OBJECTIVE: To compare the color of double-layered (DL) resin-composite (RC) samples with variant enamel-thicknesses (ET) to their corresponding shade-tabs from VITA classical (VC) and 3D-Master (V3DM).
METHODS: A2-DL samples (N = 30) fabricated using three pairs of custom-made molds with an ET of 0.5, 0.7, and 1.0 mm. Shades were selected according to the manufacturer's instructions of two RC brands: Clearfil-Majesty (CM), and Vita-l-essence (VL). A spectrophotometer measured CIE L*a*b* color parameters. We used ΔE 00 to calculate color differences among DL samples, VC, and V3DM shade-tabs. The data were analyzed using Spearman correlation coefficient, one-way ANOVA, and Tukey test (∝=0.05).
RESULTS: ΔE 00 between DL samples A2 and 2M2 shade tabs were all greater than the predetermined 50:50% acceptability threshold (ΔE 00 = 6.6-10.4). Depending on the shade tabs compared, the ΔE 00 among CM and VL ET subgroups were statistically different (P < .001). ET and L* were negatively correlated for CM and VL. For CM, ΔE 00 and L* correlated on the A2 shade tab, whereas for VL, ΔE 00 , and ET correlated on the 2M2 shade tab (P < .05).
CONCLUSIONS: The DL samples produced unacceptable color matches to their corresponding shade. An enamel layer thickness of 0.7 mm corresponded to the lowest ΔE 00 . The use of V3DM for RC shade selection should be investigated. CLINICAL SIGNIFICANCE: Understanding color interaction between RC layers is important to achieve consistent results in esthetic clinical procedures. The thickness of the enamel layer can critically alter the overall shade for a given RC shade and brand. This variation is difficult for the clinician to predict and negatively impacts patient satisfaction, increasing overall procedure costs, and decreasing efficiency. This color interaction study aims to facilitate consistency in shade reproduction.
© 2019 Wiley Periodicals, Inc.

Entities:  

Keywords:  CIEDE2000; color difference; layering; operative dentistry; resin composite

Year:  2019        PMID: 31565829     DOI: 10.1111/jerd.12530

Source DB:  PubMed          Journal:  J Esthet Restor Dent        ISSN: 1496-4155            Impact factor:   2.843


  1 in total

1.  Color difference between the vita classical shade guide and composite veneers using the dual-layer technique.

Authors:  Franciele Floriani; Bryce-Arielle Brandfon; Nathalie J Sawczuk; Guilherme-Carpena Lopes; Mateus-Garcia Rocha; Dayane Oliveira
Journal:  J Clin Exp Dent       Date:  2022-08-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.