Reproducibility of Natural Shear Wave Elastography Measurements.

Lana B H Keijzer1, Mihai Strachinaru2, Dan J Bowen3, Marcel L Geleijnse3, Antonius F W van der Steen4, Johan G Bosch3, Nico de Jong4, Hendrik J Vos4.   

Abstract

For the quantification of myocardial function, myocardial stiffness can potentially be measured non-invasively using shear wave elastography. Clinical diagnosis requires high precision. In 10 healthy volunteers, we studied the reproducibility of the measurement of propagation speeds of shear waves induced by aortic and mitral valve closure (AVC, MVC). Inter-scan was slightly higher but in similar ranges as intra-scan variability (AVC: 0.67 m/s (interquartile range [IQR]: 0.40-0.86 m/s) versus 0.38 m/s (IQR: 0.26-0.68 m/s), MVC: 0.61 m/s (IQR: 0.26-0.94 m/s) versus 0.26 m/s (IQR: 0.15-0.46 m/s)). For AVC, the propagation speeds obtained on different day were not statistically different (p = 0.13). We observed different propagation speeds between 2 systems (AVC: 3.23-4.25 m/s [Zonare ZS3] versus 1.82-4.76 m/s [Philips iE33]), p = 0.04). No statistical difference was observed between observers (AVC: p = 0.35). Our results suggest that measurement inaccuracies dominate the variabilities measured among healthy volunteers. Therefore, measurement precision can be improved by averaging over multiple heartbeats.
Copyright © 2019 The Authors. Published by Elsevier Inc. All rights reserved.

Keywords:  Elastography; High frame rate; Natural shear wave elastography; Shear waves; Tissue elasticity imaging; Valve closure; stiffness

Year:  2019        PMID: 31564460     DOI: 10.1016/j.ultrasmedbio.2019.09.002

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  2 in total

1.  A direct comparison of natural and acoustic-radiation-force-induced cardiac mechanical waves.

Authors:  Lana B H Keijzer; Annette Caenen; Jason Voorneveld; Mihai Strachinaru; Daniel J Bowen; Jens van de Wouw; Oana Sorop; Daphne Merkus; Dirk J Duncker; Antonius F W van der Steen; Nico de Jong; Johan G Bosch; Hendrik J Vos
Journal:  Sci Rep       Date:  2020-10-28       Impact factor: 4.379

2.  Testicular shear wave elastography in oligo-astheno-teratozoospermic individuals: a prospective case-control study.

Authors:  Ester Illiano; Francesco Trama; Antonio Ruffo; Giuseppe Romeo; Filippo Riccardo; Felice Crocetto; Fabrizio Iacono; Elisabetta Costantini
Journal:  Int Urol Nephrol       Date:  2021-06-10       Impact factor: 2.370

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.