Literature DB >> 31558826

Effect of congenital blepharoptosis on corneal biomechanical properties and changes after ptosis surgery.

Xingyi Li1, Chang Liu1, Zhen Mao1, Xuanwei Liang1, Zuohong Li1, Xuehua Liu1, Ruowen Gong1, Danping Huang2.   

Abstract

OBJECTIVES: We studied the difference in the corneal biomechanical parameters of ptotic and fellow eyes in patients with congenital blepharoptosis. The correlations between corneal biomechanical parameters and demographic or ocular parameters, and the changes after surgery were also researched.
METHODS: The corneal biomechanical parameters were measured by Corvis ST tonometry. The central corneal thickness (CCT), axial length (AL) and keratometry measurements were performed with LenStar LS900, and intraocular pressure (IOP) by non-contact applanation tonometry. The parameters were evaluated for the effect of ptosis and the relationship of corneal biomechanical parameters. These examinations were repeated 6 months after blepharoptosis surgery.
RESULTS: Twenty-nine patients were enroled. The Corvis ST parameters (Deformation amplitude [DA], A1 times, and A1 velocity), CCT, IOP with NCT, IOP with corrected, differed significantly between ptotic and fellow eyes. CCT was significantly positively correlated with Length A1 and IOP with Corvis, and negatively correlated with IOP corrected by Corvis of the ptotic eyes. The same tendency was found in the fellow eyes. Six months after the ptosis surgery, the differences in corneal biomechanics parameters between ptotic eyes and fellow eyes were not significantly changed.
CONCLUSIONS: Congenital blepharoptosis causes significant corneal biomechanical changes measured by Corvis ST. The ptotic eyes had thicker and less deformable corneas. The differences in corneal biomechanics between ptotic eyes and fellow eyes were mostly related to CCT changes. Six months after surgery, these differences in corneal biomechanics did not change significantly.

Entities:  

Mesh:

Year:  2019        PMID: 31558826      PMCID: PMC7253465          DOI: 10.1038/s41433-019-0586-9

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  1 in total

1.  Changes in astigmatism after surgery for congenital ptosis.

Authors:  W Cadera; R B Orton; O Hakim
Journal:  J Pediatr Ophthalmol Strabismus       Date:  1992 Mar-Apr       Impact factor: 1.402

  1 in total
  1 in total

1.  Refractive error characteristics and influence on ocular parameters in patients with unilateral congenital ptosis.

Authors:  Yingli Liu; Tingting Chen; Jingwen Huang; Wentao Li; Yilin Chen; Lijun Huo
Journal:  BMC Ophthalmol       Date:  2022-07-02       Impact factor: 2.086

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.