Literature DB >> 31550537

Evaluation of Balloon Test Occlusion Before Therapeutic Carotid Artery Occlusion: Flat Detector Computed Tomography Cerebral Blood Volume Imaging versus Single-Photon Emission Computed Tomography.

Ayako Ikemura1, Ichiro Yuki2, Katharina Otani3, Toshihiro Ishibashi4, Chihebeddine Dahmani5, Masaki Ebara4, Yukiko Abe6, Ikki Kajiwara4, Mitsuyoshi Watanabe4, Yuichi Murayama4.   

Abstract

OBJECTIVE: We aimed to compare flat detector computed tomography cerebral blood volume (FD-CBV) imaging to single-photon emission computed tomography (SPECT) as an adjunctive technique during balloon test occlusion (BTO) in patients with intracranial aneurysms or tumors.
METHODS: Twelve patients who underwent SPECT (99mTc-ethyl cysteinate dimer) and FD-CBV imaging during BTO were enrolled. Color-coded cerebral blood flow (CBF) images and color-coded FD-CBV images were generated and visually inspected whether there were asymmetries between the ipsilateral and contralateral cerebral hemispheres. Region of interest measurements were performed on the color-coded images at the same locations for both modalities. The mean interhemispheric region of interest ratios were calculated, and the ratio between these were estimated using linear regression models.
RESULTS: Ten patients had no symptoms during BTO. Two patients developed subtle but inconclusive neurologic changes approximately 10 minutes after balloon inflation; their images showed asymmetric color-coded images with decreased CBF and FD-CBV in the ipsilateral hemisphere. The mean interhemispheric ratio of CBF was significantly smaller in patients with subtle changes than in those without (0.84 vs. 0.98; P < 0.001). Similarly, the mean interhemispheric ratio of FD-CBV was significantly smaller in patients with subtle changes than in those without (0.88 vs. 1.06; P = 0.01). No patient showed increased CBF or FD-CBV in the ipsilateral hemisphere.
CONCLUSIONS: The patients with decreased CBF on SPECT also showed decreased FD-CBV in the ipsilateral hemisphere. FD-CBV imaging may be useful as an adjunctive technique for BTO before potential therapeutic carotid artery occlusion.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Balloon test occlusion; Flat detector computed tomography cerebral blood volume; Internal carotid occlusion; Single-photon emission computed tomography

Year:  2019        PMID: 31550537     DOI: 10.1016/j.wneu.2019.09.077

Source DB:  PubMed          Journal:  World Neurosurg        ISSN: 1878-8750            Impact factor:   2.104


  5 in total

1.  The Sutureless Excimer Laser Anastomosis Clip Pilot Study: a feasibility and safety study.

Authors:  Albert van der Zwan; Kiki Gortzak; Bart de Boer; Saskia Redegeld; Sander van Thoor; Cornelius Tulleken
Journal:  Acta Neurochir (Wien)       Date:  2022-05-07       Impact factor: 2.816

2.  Diagnostic Impact of Monitoring Visual Evoked Potentials to Prevent Visual Complications During Endovascular Treatment for Intracranial Aneurysm.

Authors:  Ichiro Nakagawa; HunSoo Park; Masashi Kotsugi; Shohei Yokoyama; Kouji Omoto; Kaoru Myochin; Yasuhiro Takeshima; Ryosuke Matsuda; Fumihiko Nishimura; Shuichi Yamada; Tsunenori Takatani; Hiroyuki Nakase
Journal:  Front Neurol       Date:  2022-02-23       Impact factor: 4.003

3.  Emergency extra-intracranial bypass surgery in a patient with neurologic deficit after an accident in carotid occlusive test: A case report.

Authors:  Hung M Ngo; Hien T Trinh; Rocky Felbaum; Walter Jean
Journal:  Int J Surg Case Rep       Date:  2022-04-12

Review 4.  Flat Detector CT with Cerebral Pooled Blood Volume Perfusion in the Angiography Suite: From Diagnostics to Treatment Monitoring.

Authors:  Thijs van der Zijden; Annelies Mondelaers; Maurits Voormolen; Tomas Menovsky; Maarten Niekel; Thomas Jardinet; Thomas Van Thielen; Olivier D'Archambeau; Paul M Parizel
Journal:  Diagnostics (Basel)       Date:  2022-08-13

5.  Distal Vessel Imaging via Intra-arterial Flat Panel Detector CTA during Mechanical Thrombectomy.

Authors:  T Nozaki; M Noda; T Ishibashi; K Otani; M Kogiku; K Abe; H Kishi; A Morita
Journal:  AJNR Am J Neuroradiol       Date:  2020-12-24       Impact factor: 3.825

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.