| Literature DB >> 31547514 |
Nora Hamad Al-Shaalan1, Imran Ali2,3, Zeid A ALOthman4, Lamya Hamad Al-Wahaibi5, Hadeel Alabdulmonem6.
Abstract
Composite nanoparticles were used in solid phase micro membrane tip extraction and capillary electrophoresis to determine phenol and p-amino-phenol in wastewater. The optimized conditions were 100 g/L concentration, 40 min contact time, 11 pH, 5 mg/mL nanoparticles amounts, 60 min desorption time, 9 desorption pH and 298 K temperature. Capillary electrophoresis conditions were phosphate buffer (15 mM, pH 7.0) background electrolyte, 18 kV applied voltage, 214 nm UV detection, 30 s sample loading at 23 ± 1 °C. The maximum percent uptakes of p-amino-phenol and phenol were 80.0 and 85.0%. High ratio recoveries of p-amino-phenol and phenol from nanomaterial were 99.0 and 98. Consequently, the actual extractions of p-amino-phenol and phenol from wastewater were 79.2 and 83.30 percent. The migration times of phenol and p-amino-phenol and were 9.0 and 12.0 min. The detection limits of phenol and p-amino-phenols were 0.1 and 0.2 µg/L after extraction and CE. Therefore, this combination of solid phase micro membrane tip extraction and capillary electrophoresis may be considered as the ideal one for monitoring of toxic phenol and p-amino-phenol in water sample.Entities:
Keywords: 3-aminophenol; SPMMTE; capillary electrophoresis; phenol; wastewater
Mesh:
Substances:
Year: 2019 PMID: 31547514 PMCID: PMC6804077 DOI: 10.3390/molecules24193443
Source DB: PubMed Journal: Molecules ISSN: 1420-3049 Impact factor: 4.411
Figure 1The supra molecular structure of the composite iron nanoparticle.
Validation parameters of capillary electrophoresis.
| Sl. No. | Validated Parameters | % RSD | Correlation Coefficients | Confidence Levels |
|---|---|---|---|---|
| 1. | Linearity | 0.55–1.20 | 0.9996–0.9997 | 97.0–96.2 |
| 2. | LOD | 0.85–1.30 | 0.9995–0.9996 | 95.5–96.1 |
| 3. | LOQ | 0.83–0.102 | 0.9995–0.9996 | 96.6–96.0 |
| 4. | Specificity | 0.73–0.93 | 0.9995–0.9996 | 97.0–96.1 |
| 5. | Accuracy | 0.69–0.87 | 0.9996–0.9998 | 96.2–96.2 |
| 5. | Precision | 0.58–0.71 | 0.9996–0.9998 | 96.2–97.0 |
| 6. | Ruggedness | 0.89–1.40 | 0.9995–0.9996 | 96.7–96.6 |
Figure 2Effect of initial concentrations of phenols.
Figure 3Effect of extraction time of phenols.
Figure 4Effect of pH of the solutions of phenols.
Figure 5Effect of amount of nanoparticles enclosed in the membrane cone.
Figure 6Effect of desorption time for phenols.
Figure 7Effect of pH for desorption of phenols.
Figure 8Chemical structures of phenol and p-nitro-phenol.
Figure 9Solid phase micro membrane tip extraction assembly.