Literature DB >> 31531868

Safety and efficacy of transvenous lead extractions for noninfectious superfluous leads in a Japanese population: A single-center experience.

Satoshi Higuchi1, Morio Shoda1, Satoshi Saito2, Miwa Kanai1, Shohei Kataoka1, Kyoichiro Yazaki1, Daigo Yagishita1, Koichiro Ejima1, Nobuhisa Hagiwara1.   

Abstract

BACKGROUND: A challenging decision exists as whether to abandon or remove noninfectious superfluous leads during lead revisions or cardiac implantable electronic device (CIED) upgrades. There is insufficient data in the Asian population to guide decision making.
METHODS: This study investigated the safety and efficacy of transvenous lead extractions (TLEs) in a high-volume Japanese center. Among a total of 341 patients who underwent lead revisions or CIED upgrades between 2008 and 2018, 53 patients (16%) who underwent TLEs to remove the superfluous leads were analyzed.
RESULTS: Indications for TLE were vascular issues (60%), recalled leads (21%), growth of the body size (6%), abandoned leads in young patients (6%), switch to a subcutaneous implanted cardiac defibrillator (4%), need for an MRI conditional CIED (2%), and risks of vascular injury (2%). The population included 29 patients (55%) with nonfunctional leads and 24 (45%) with functional abandoned leads. A total of 74 target leads (mean 1.4 leads/person, median lead age 6.7 years) were extracted with a complete removal achieved in 98%. All coexisting leads, intended for continued use, were not damaged. All new leads (mean 1.4 leads/person) that had been simultaneously implanted during the TLE procedures were successfully implanted. There was one minor complication (2%) involving a pericardial effusion but it did not affect the hemodynamics.
CONCLUSIONS: In this Japanese single center experience, the removal of noninfectious superfluous leads with TLEs seemed to be a safe and effective therapeutic option.
© 2019 Wiley Periodicals, Inc.

Entities:  

Keywords:  abandoned lead; cardiac implantable electronic devices; noninfectious; transvenous lead extraction

Year:  2019        PMID: 31531868     DOI: 10.1111/pace.13806

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

1.  Study Design of the Nationwide Japanese Lead Extraction (J-LEX) Registry: Protocol for a Prospective, Multicenter, Open Registry.

Authors:  Morio Shoda; Kengo Kusano; Masahiko Goya; Nobuhiro Nishii; Katsuhiko Imai; Yoji Okamoto; Misa Takegami; Yoko M Nakao; Yoshihiro Miyamoto; Akihiko Nogami
Journal:  J Arrhythm       Date:  2020-07-10

2.  Leadless cardiac pacemaker implantations after infected pacemaker system removals in octogenarians.

Authors:  Satoshi Higuchi; Ayako Okada; Morio Shoda; Daigo Yagishita; Satoshi Saito; Miwa Kanai; Shohei Kataoka; Kyoichiro Yazaki; Hiroaki Tabata; Hideki Kobayashi; Wataru Shoin; Takahiro Okano; Koji Yoshie; Koichiro Ejima; Koichiro Kuwahara; Nobuhisa Hagiwara
Journal:  J Geriatr Cardiol       Date:  2021-07-28       Impact factor: 3.327

3.  The Use of Transvenous Lead Extraction of Non-Infected Leads to Prevent Long-Term Lead-Related Complications.

Authors:  S A Ayvazyan; A B Gamzaev; A A Palagina; K G Gorshenin; S I Buslaeva; A A Seregin; N S Konovalov; O V Sapelnikov
Journal:  Sovrem Tekhnologii Med       Date:  2021-02-28

4.  Japanese Lead EXtraction (J-LEX) registry: Annual report 2019.

Authors:  Morio Shoda; Kengo Kusano; Masahiko Goya; Nobuhiro Nishii; Katsuhiko Imai; Yoji Okamoto; Misa Takegami; Yoko M Nakao; Yoshihiro Miyamoto; Akihiko Nogami; Wataru Shimizu
Journal:  J Arrhythm       Date:  2022-02-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.