Literature DB >> 31531286

Differences in Trabecular Bone, Cortical Shell, and Endplate Microstructure Across the Lumbar Spine.

Vivek Palepu1, Sai Deepa Rayaprolu1, Srinidhi Nagaraja1.   

Abstract

BACKGROUND: The quality of the vertebral body structures such as endplate, cortex, and trabecular bone is important for understanding the performance of implants, particularly at the bone-implant interface. Although vertebral body structures have been analyzed separately in the literature, there is no comprehensive study to assess these anatomical measurements along with their interrelationships in the lumbar spine. Therefore, the purpose of this study was to assess variations in trabecular microstructure, vertebral endplate thickness and concavity, and vertebral body cortex thickness within the lumbar spine.
METHODS: A total of 80 lumbar vertebrae (L1-L5) were dissected from 16 human cadaver specimens and imaged with microcomputed tomography to determine trabecular microstructure, vertebral cortex thickness, endplate thickness, and maximum endplate concavity depth. A paired t test and regression analysis were used to determine significant differences (P < .05) between different vertebral levels and correlations between the analyzed anatomical parameters.
RESULTS: L1 vertebra had significantly better (P < .02) trabecular bone microstructure (eg, trabecular bone volume fraction) than all other lumbar vertebrae. However, L1 vertebra also had significantly thinner (P ≤ .02) anterior, left, and right cortices compared to all other vertebral levels. Within L3-L5 intervertebral disc spaces, cranial endplates had significantly greater (P ≤ .03) thickness and maximum concavity depth compared to their respective caudal endplates. No strong correlations were observed between trabecular bone microstructure, maximum endplate concavity depth, vertebral cortex, and endplate thickness parameters.
CONCLUSIONS: Detailed reference data of these anatomical parameters for each lumbar vertebral body can aid in improved understanding of bone quality, particularly when assessing different implant designs and fixation approaches. Moreover, such anatomical knowledge may help clinicians with optimal implant design selection and surgical placement of these devices into their respective locations.

Entities:  

Keywords:  anatomy; endplate concavity depth; endplate thickness; lumbar spine; trabecular bone microstructure; vertebral cortex thickness

Year:  2019        PMID: 31531286      PMCID: PMC6724757          DOI: 10.14444/6049

Source DB:  PubMed          Journal:  Int J Spine Surg        ISSN: 2211-4599


  34 in total

1.  Direct three-dimensional morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus.

Authors:  T Hildebrand; A Laib; R Müller; J Dequeker; P Rüegsegger
Journal:  J Bone Miner Res       Date:  1999-07       Impact factor: 6.741

Review 2.  Targeted and nontargeted bone remodeling: relationship to basic multicellular unit origination and progression.

Authors:  A M Parfitt
Journal:  Bone       Date:  2002-01       Impact factor: 4.398

Review 3.  The aging of Wolff's "law": ontogeny and responses to mechanical loading in cortical bone.

Authors:  Osbjorn M Pearson; Daniel E Lieberman
Journal:  Am J Phys Anthropol       Date:  2004       Impact factor: 2.868

4.  Cage migration in spondylolisthesis treated with posterior lumbar interbody fusion using BAK cages.

Authors:  Liang Chen; Huilin Yang; Tiansi Tang
Journal:  Spine (Phila Pa 1976)       Date:  2005-10-01       Impact factor: 3.468

5.  Age-related changes in trabecular bone microstructures: global and local morphometry.

Authors:  M Stauber; R Müller
Journal:  Osteoporos Int       Date:  2005-12-31       Impact factor: 4.507

6.  Antero-postero differences in cortical thickness and cortical porosity of T12 to L5 vertebral bodies.

Authors:  Nicola L Fazzalari; Ian H Parkinson; Quentin A Fogg; Peter Sutton-Smith
Journal:  Joint Bone Spine       Date:  2005-12-07       Impact factor: 4.929

7.  Structural features and thickness of the vertebral cortex in the thoracolumbar spine.

Authors:  W T Edwards; Y Zheng; L A Ferrara; H A Yuan
Journal:  Spine (Phila Pa 1976)       Date:  2001-01-15       Impact factor: 3.468

8.  Human lumbar vertebrae. Quantitative three-dimensional anatomy.

Authors:  M M Panjabi; V Goel; T Oxland; K Takata; J Duranceau; M Krag; M Price
Journal:  Spine (Phila Pa 1976)       Date:  1992-03       Impact factor: 3.468

9.  Measurement and analyses of the effects of adjacent end plate curvatures on vertebral stresses.

Authors:  Noshir A Langrana; Shreedhar P Kale; W Thomas Edwards; Casey K Lee; Kenneth J Kopacz
Journal:  Spine J       Date:  2006 May-Jun       Impact factor: 4.166

10.  Anterior lumbar fusion with paired BAK standard and paired BAK Proximity cages: subsidence incidence, subsidence factors, and clinical outcome.

Authors:  William J Beutler; Walter C Peppelman
Journal:  Spine J       Date:  2003 Jul-Aug       Impact factor: 4.166

View more
  2 in total

1.  Measuring the thickness of vertebral endplate and shell using digital tomosynthesis.

Authors:  Yener N Yeni; Michael R Dix; Angela Xiao; Daniel J Oravec; Michael J Flynn
Journal:  Bone       Date:  2022-01-28       Impact factor: 4.398

Review 2.  Trabecular Architecture and Mechanical Heterogeneity Effects on Vertebral Body Strength.

Authors:  Joshua D Auger; Neilesh Frings; Yuanqiao Wu; Andre Gutierrez Marty; Elise F Morgan
Journal:  Curr Osteoporos Rep       Date:  2020-11-20       Impact factor: 5.096

  2 in total