Gradual correction of proximal tibia deformity for Blount disease in adolescent and young adults.

Aik Saw1, Zi Hao Phang1, Mohammed Khalid Alrasheed2, Roshan Gunalan1, Mohammed Ziyad Albaker1, Rukmanikanthan Shanmugam1.   

Abstract

PURPOSE: Management of Blount disease in adolescents and young adults is complex and associated with high risk of morbidities. Gradual correction with external fixator can minimize soft tissue injury and allow subsequent adjustment in degree of correction. This study investigates the surgical outcome and complication rate of gradual correction of neglected Blount disease through single-level extra-articular corticotomy.
METHODS: Patients treated for Blount disease using external fixator from 2002 to 2016 were recruited for the study. We used Ilizarov and Taylor Spatial Frame (TSF) external fixator to perform simultaneous correction of all the metaphyseal deformities without elevating the tibia plateau. Surgical outcome was evaluated using mechanical axis deviation (MAD), tibial femoral angle (TFA), and femoral condyle tibial shaft angle (FCTSA).
RESULTS: A total of 22 patients with 32 tibias have been recruited for the study. The mean MAD improved from 95 ± 51.4 mm to 9.0 ± 37.7 mm (medial to midpoint of the knee), mean TFA improved from 31 ± 15° varus to 2 ± 14° valgus, and mean FCTSA improved from 53 ± 14° to 86 ± 14°. Mean duration of frame application is 9.4 months. Two patients developed pathological fractures over the distracted bones, one developed delayed consolidation and other developed overcorrection.
CONCLUSIONS: Correction of Blount disease can be achieved by gradual correction using Ilizarov or TSF external fixator with low risk of soft tissue complication. Longer duration of frame application should be considered to reduce the risk of pathological fracture or subsequent deformation of the corrected bone.

Entities:  

Keywords:  Blount disease; deformity; genu varum; mechanical axis deviation

Year:  2019        PMID: 31530084     DOI: 10.1177/2309499019873987

Source DB:  PubMed          Journal:  J Orthop Surg (Hong Kong)        ISSN: 1022-5536            Impact factor:   1.118


  3 in total

1.  Improving postoperative radiographs for the parameter measurement of hexapod external fixator using an additional foot ring.

Authors:  Yanshi Liu; Kai Liu; Feiyu Cai; Tao Zhang; Aihemaitijiang Yusufu
Journal:  J Orthop Surg Res       Date:  2021-11-13       Impact factor: 2.359

2.  Staged correction trajectory with hexapod external fixator for the satisfactory reduction of long bone shaft fracture.

Authors:  Yanshi Liu; Fei Wang; Kai Liu; Feiyu Cai; Xingpeng Zhang; Hong Li; Tao Zhang; Aihemaitijiang Yusufu
Journal:  BMC Musculoskelet Disord       Date:  2022-03-08       Impact factor: 2.362

3.  Long bone fracture reduction and deformity correction using the hexapod external fixator with a new method: a feasible study and preliminary results.

Authors:  Yanshi Liu; Hong Li; Jialin Liu; Xingpeng Zhang; Maimaiaili Yushan; Zhenhui Liu; Chuang Ma; Aihemaitijiang Yusufu
Journal:  BMC Musculoskelet Disord       Date:  2021-02-24       Impact factor: 2.362

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.