Literature DB >> 31525898

Chemiluminescence Immunoassays for Simultaneous Detection of Three Heart Disease Biomarkers Using Magnetic Carbon Composites and Three-Dimensional Microfluidic Paper-Based Device.

Rui Yang1, Fang Li2, Wencan Zhang1, Wen Shen1, Di Yang3, Zhiping Bian3, Hua Cui1.   

Abstract

Chemiluminescence (CL) immunoassays for simultaneous detection of early acute myocardial infarction (AMI) biomarkers, including copeptin, heart-type fatty acid binding protein (h-FABP), and cardiac troponin I (cTnI), were developed by using Co2+/N-(aminobutyl)-N-(ethylisoluminol) (ABEI) functionalized magnetic carbon composite (Co2+-ABEI-Fe3O4@void@C) as an interface and a three-dimensional microfluidic paper-based device (3D μPAD) as a detection system. For CL immunoassays, Co2+-ABEI-Fe3O4@void@C was assembled with chitosan (CS) and gold nanoparticle-conjugated antibody (Au-Ab) sequentially to form the sensing platform (Co2+-ABEI-Fe3O4@void@C-CS/Au-Ab). In the presence of antigen (Ag), Ag was captured by the sensing interface to form an immunocomplex, leading to an increase in CL intensity due to the catalysis of -COO- existing in Ag. A 3D μPAD with three detection zones for simultaneous detection of copeptin, h-FABP, and cTnI was designed and fabricated to obtain time-resolved CL signals. Three kinds of immunocomplexes formed with copeptin, h-FABP, and cTnI were added to three detection zones of 3D μPAD, respectively. After injecting H2O2, three time-resolved CL signals were generated in one CL detection run by virtue of time-delayed transport of H2O2 to different detection zones. The three time-resolved CL signals were used for the simultaneous determination of copeptin, h-FABP, and cTnI. The detection limit of copeptin, h-FABP, and cTnI was 0.40 pg/mL, 0.32 pg/mL, and 0.50 pg/mL, respectively, which is at least 1 order of magnitude lower than most of the reported immunoassays. The immunoassays could be directly used for the detection of copeptin, h-FABP, and cTnI in human serum samples. The proposed immunoassays are simple, fast, sensitive, and selective, and are of great application potential in early diagnosis and treatment of AMI.

Entities:  

Year:  2019        PMID: 31525898     DOI: 10.1021/acs.analchem.9b03066

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

Review 1.  Strategies for the detection of target analytes using microfluidic paper-based analytical devices.

Authors:  Wei Zheng; Kan Wang; Hao Xu; Chujun Zheng; Bo Cao; Qi Qin; Qinghui Jin; Daxiang Cui
Journal:  Anal Bioanal Chem       Date:  2021-03-13       Impact factor: 4.142

Review 2.  Recent Advances in Microfluidic Paper-Based Analytical Devices toward High-Throughput Screening.

Authors:  Siraprapa Boobphahom; Mai Nguyet Ly; Veasna Soum; Nayoon Pyun; Oh-Sun Kwon; Nadnudda Rodthongkum; Kwanwoo Shin
Journal:  Molecules       Date:  2020-06-28       Impact factor: 4.411

3.  Detection of Carbohydrate Antigen 50 Based on a Novel Miniaturized Chemiluminescence Analyzer Enables Large-Scale Cancer Early Screening in Grassroots Community.

Authors:  Yu Liu; Xiaowei He; Jingjing Zou; Xiuyun Ouyang; Chunrong Huang; Xiao Yang; Yu Wang
Journal:  Front Bioeng Biotechnol       Date:  2022-07-07

Review 4.  Advanced Signal-Amplification Strategies for Paper-Based Analytical Devices: A Comprehensive Review.

Authors:  Thi Xoan Hoang; Le Minh Tu Phan; Thuy Anh Thu Vo; Sungbo Cho
Journal:  Biomedicines       Date:  2021-05-12

5.  Rapid chiral analysis based on liquid-phase cyclic chemiluminescence.

Authors:  Runkun Zhang; Yanhui Zhong; Zhenyu Lu; Yanlong Chen; Gongke Li
Journal:  Chem Sci       Date:  2020-10-22       Impact factor: 9.825

Review 6.  Application of Microfluidics in Immunoassay: Recent Advancements.

Authors:  Yuxing Shi; Peng Ye; Kuojun Yang; Jie Meng; Jiuchuan Guo; Zhixiang Pan; Qiaoge Bayin; Wenhao Zhao
Journal:  J Healthc Eng       Date:  2021-07-15       Impact factor: 2.682

  6 in total